scholarly journals Inhibition effect of sodium benzoate, zinc benzoate and zinc bromide on low carbon steel corrosion in dilute H2SO4 and HCL solution

Author(s):  
Roland Tolulope loto
2019 ◽  
Vol 3 (1) ◽  
pp. 263-276 ◽  
Author(s):  
Hameed B. Mahood ◽  
Asaad H. Sayer ◽  
Athraa H. Mekky ◽  
Anees A. Khadom

2020 ◽  
Vol 11 (1) ◽  
pp. 1-13
Author(s):  
Roland Tolulope Loto ◽  
Samuel Keme Ororo

AbstractInhibition effect of the synergistic combination of thymus mastichina and illicium verum oil extracts (TMAV) on the corrosion inhibition of low carbon steel in 0.5 M H2SO4 and HCl solution was studied by weight loss analysis, potentiodynamic polarization, open circuit potential measurement, ATF-FTIR spectroscopy, and optical microscopy and macroscopic characterization. Results from weight loss shows TMAV performed more effectively in H2SO4 solution compared to HCl with optimal inhibition efficiency of 81.24% and 68.33%. Effective inhibition performance was observed at all TMAV concentration in H2SO4 compared to HCl where TMAV performed poorly until 5% concentration. The optimal inhibition performances from potentiodynamic polarization are 80.85% and 70.43%. The corresponding corrosion current density and polarization resistance are 7.16 × 105 A/cm2 and 8.01 × 105 A/cm2, and 331.73 and 284 Ω. TMAV exhibited mixed type inhibition effect in both acid solutions, strongly influencing the anodic-cathodic plot configurations with respect to concentration. Open circuit potential plots without TMAV were significantly electronegative compared to the plots at 1% and 5% TMAV concentration which were relative electropositive due to decreased thermodynamic tendency of the carbon steel to corrode. The corresponding plots at 1% and 5% TMAV concentration from HCl solution were thermodynamically unstable with significant active-passive corrosion behaviour. TMAV inhibited through chemisorption adsorption according to Langmuir and Freudlich adsorption isotherms in H2SO4 solution, and Frumkin and Freundlich adsorption isotherms in HCl solution with correlation coefficient values between 0.7 and 0.9. FTIR spectroscopic analysis exposed the functional groups and atomic bonds responsible for corrosion inhibition.


2016 ◽  
Vol 30 (21) ◽  
pp. 2383-2403 ◽  
Author(s):  
Husnu Gerengi ◽  
H. Ibrahim Ugras ◽  
Moses M. Solomon ◽  
Saviour A. Umoren ◽  
Mine Kurtay ◽  
...  

2021 ◽  
Vol 6 (13) ◽  
pp. 3199-3217
Author(s):  
Nurudeen A. Odewunmi ◽  
Mohammad A. J. Mazumder ◽  
Shaikh A. Ali

MRS Advances ◽  
2017 ◽  
Vol 2 (62) ◽  
pp. 3909-3915
Author(s):  
Héctor M. Barbosa Cásarez ◽  
Araceli Espinoza Vázquez ◽  
Francisco J. Rodríguez-Gomez

AbstractPhenylcoumarin glucoside (4-PC) is a compound extracted from the plant Hintona latiflora and was studied as inhibitor for AISI 1018 steel corrosion in 3% NaCl solution using potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques, which may find application as eco-friendly corrosion inhibitors. The 4-PC provides inhibitor properties that protect AISI 1018 low carbon steel against corrosion at low concentrations (5 ppm) obtained by EIS. Polarization studies showed that the inhibitor was of mixed type. The inhibition efficiency by the two electrochemical techniques shows similar results. The inhibitor adsorption was demonstrated to be a combined process (physisorption and chemisorption) according to the Langmuir isotherm.


Author(s):  
Ya.G. Avdeev ◽  
◽  
A.V. Panova ◽  
T.E. Andreeva ◽  
Yu.I. Kuznetsov ◽  
...  

Corrosion of 08PS low-carbon steel was studied in a wide temperature range t = 25—100 °C in 1 M H2SO4 + 1 M H3PO4, 2 M H2SO4 и 2 M H3PO4, inhibited by the binary mixture IFKhAN-92 + KNCS (a molar ratio of components 9:1) and a three-component mixture IFKhAN-92 + KNCS + urotropine (9:1:400), in the presence of high concentrations of Fe(III) and Fe(II) salts, as well as in their joint presence. It is shown that under experimental conditions the corrosion inhibitors under study provide effective protection of steel in 1 M H2SO4 + 1 M H3PO4 even in the presence of Fe(III), Fe(II) salts or their mixtures. The highest protective effects are provided by a three-component inhibitor mixture. Under similar conditions in individual 2 M H3PO4 and, especially, 2 M H2SO4, the protective effects of inhibitors are lower. A stronger deceleration of steel corrosion by composite inhibitors based on IFKhAN-92 in H2SO4 + H3PO4 solutions containing Fe(III) salts in comparison with similar solutions of individual H2SO4, is largely due to the binding of Fe(III) cations by phosphate anions into complexes, that significantly reduces their chemical activity and, as a result the corrosion rate of steel.


Sign in / Sign up

Export Citation Format

Share Document