Flat Panel Detector c-Arms Are Associated with Dramatically Reduced Radiation Exposure During Ureteroscopy and Produce Superior Images

2021 ◽  
Author(s):  
Jason J. Lee ◽  
Alyssia M. Venna ◽  
Ian McCarthy ◽  
Bartley G. Cilento ◽  
Michael G. Demers ◽  
...  
2020 ◽  
Vol 33 (6) ◽  
pp. 838-844
Author(s):  
Jan-Helge Klingler ◽  
Ulrich Hubbe ◽  
Christoph Scholz ◽  
Florian Volz ◽  
Marc Hohenhaus ◽  
...  

OBJECTIVEIntraoperative 3D imaging and navigation is increasingly used for minimally invasive spine surgery. A novel, noninvasive patient tracker that is adhered as a mask on the skin for 3D navigation necessitates a larger intraoperative 3D image set for appropriate referencing. This enlarged 3D image data set can be acquired by a state-of-the-art 3D C-arm device that is equipped with a large flat-panel detector. However, the presumably associated higher radiation exposure to the patient has essentially not yet been investigated and is therefore the objective of this study.METHODSPatients were retrospectively included if a thoracolumbar 3D scan was performed intraoperatively between 2016 and 2019 using a 3D C-arm with a large 30 × 30–cm flat-panel detector (3D scan volume 4096 cm3) or a 3D C-arm with a smaller 20 × 20–cm flat-panel detector (3D scan volume 2097 cm3), and the dose area product was available for the 3D scan. Additionally, the fluoroscopy time and the number of fluoroscopic images per 3D scan, as well as the BMI of the patients, were recorded.RESULTSThe authors compared 62 intraoperative thoracolumbar 3D scans using the 3D C-arm with a large flat-panel detector and 12 3D scans using the 3D C-arm with a small flat-panel detector. Overall, the 3D C-arm with a large flat-panel detector required more fluoroscopic images per scan (mean 389.0 ± 8.4 vs 117.0 ± 4.6, p < 0.0001), leading to a significantly higher dose area product (mean 1028.6 ± 767.9 vs 457.1 ± 118.9 cGy × cm2, p = 0.0044).CONCLUSIONSThe novel, noninvasive patient tracker mask facilitates intraoperative 3D navigation while eliminating the need for an additional skin incision with detachment of the autochthonous muscles. However, the use of this patient tracker mask requires a larger intraoperative 3D image data set for accurate registration, resulting in a 2.25 times higher radiation exposure to the patient. The use of the patient tracker mask should thus be based on an individual decision, especially taking into considering the radiation exposure and extent of instrumentation.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Yashar Naseri ◽  
Ulrich Hubbe ◽  
Christoph Scholz ◽  
Johannes Brönner ◽  
Marie T. Krüger ◽  
...  

Abstract Background Intraoperative 3-dimensional (3D) navigation is increasingly being used for pedicle screw placement. For this purpose, dedicated mobile 3D C-arms are capable of providing intraoperative fluoroscopy-based 3D image data sets. Modern 3D C-arms have a large field of view, which suggests a higher radiation exposure. In this experimental study we therefore investigate the radiation exposure of a new mobile 3D C-arm with large flat-panel detector to a previously reported device with regular flat-panel detector on an Alderson phantom. Methods We measured the radiation exposure of the Vision RFD 3D (large 30 × 30 cm detector) while creating 3D image sets as well as standard fluoroscopic images of the cervical and lumbar spine using an Alderson phantom. The dosemeter readings were then compared with the radiation exposure of the previous model Vision FD Vario 3D (smaller 20 × 20 cm detector), which had been examined identically in advance and published elsewhere. Results The larger 3D C-arm induced lower radiation exposures at all dosemeter sites in cervical 3D scans as well as at the sites of eye lenses and thyroid gland in lumbar 3D scans. At ​​male and especially female gonads in lumbar 3D scans, however, the larger 3D C-arm showed higher radiation exposures compared with the smaller 3D C-arm. In lumbar fluoroscopic images, the dosemeters near/in the radiation field measured a higher radiation exposure using the larger 3D C-arm. Conclusions The larger 3D C-arm offers the possibility to reduce radiation exposures for specific applications despite its larger flat-panel detector with a larger field of view. However, due to the considerably higher radiation exposure of the larger 3D C-arm during lumbar 3D scans, the smaller 3D C-arm is to be recommended for short-distance instrumentations (mono- and bilevel) from a radiation protection point of view. The larger 3D C-arm with its enlarged 3D image set might be used for long instrumentations of the lumbar spine. From a radiation protection perspective, the use of the respective 3D C-arm should be based on the presented data and the respective application.


2007 ◽  
Vol 28 (10) ◽  
pp. 1902-1908 ◽  
Author(s):  
G. Richter ◽  
T. Engelhorn ◽  
T. Struffert ◽  
M. Doelken ◽  
O. Ganslandt ◽  
...  

2016 ◽  
Vol 56 (5) ◽  
pp. 257-263 ◽  
Author(s):  
Hidetaka ARISHIMA ◽  
Satoshi KAWAJIRI ◽  
Hiroshi ARAI ◽  
Yoshifumi HIGASHINO ◽  
Toshiaki KODERA ◽  
...  

Radiology ◽  
2005 ◽  
Vol 237 (2) ◽  
pp. 691-700 ◽  
Author(s):  
Okka W. Hamer ◽  
Claude B. Sirlin ◽  
Michael Strotzer ◽  
Ingitha Borisch ◽  
Niels Zorger ◽  
...  

2005 ◽  
Vol 16 (1) ◽  
pp. 221-226 ◽  
Author(s):  
Margareta Jansson ◽  
Håkan Geijer ◽  
Jan Persliden ◽  
Torbjörn Andersson