Histological Validation of Cone-Beam Computed Tomography Versus Laser Fluorescence and Conventional Diagnostic Methods for Occlusal Caries Detection

2015 ◽  
Vol 33 (2) ◽  
pp. 61-68 ◽  
Author(s):  
Elif Ozturk ◽  
Alper Sinanoglu
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Friederike Litzenburger ◽  
Gerrit Schäfer ◽  
Reinhard Hickel ◽  
Jan Kühnisch ◽  
Katrin Heck

Abstract Background The purpose of this prospective clinical diagnostic study with validation was to compare the diagnostic accuracy of near-infrared transillumination (NIRT), laser fluorescence measurement (LF), alternating current impedance spectroscopy (ACIS) and their combinations as adjunct methods to visual examination (VE) for occlusal caries detection using a hybrid reference standard. Methods Ninety-six first and second non-cavitated permanent molars from 76 individuals (mean age 24.2) were investigated using (VE) (ICDAS) and bitewing radiography (BWR), as well as NIRT, LF and ACIS. The findings of BWR and NIRT were evaluated by two examiners while the other examinations were conducted by one calibrated dentist. The hybrid reference standard consisted of non-operative validation based on the results of VE and BWR and operative validation. Statistical analysis included cross-tabulations, calculation of sensitivity, specificity and area under the receiver operating characteristic curve at three diagnostic thresholds: caries in general, enamel caries and dentin caries. Results NIRT, LF and ACIS exhibited high sensitivity for caries in general [1.00 (1.00–1.00), 0.77 (0.65–0.88), 0.75 (0.63–0.87)) and for dentin caries (0.97 (0.91–1.03), 0.76 (0.76–0.90), 0.64 (0.47–0.80)]. Sensitivity values for enamel caries were weak (0.21, 0.11, 0.37). Specificity values did not fall below 0.65 (NIRT) for all categories and methods, except for NIRT at the caries detection threshold (0.27). A combination of LF and ACIS with VE improved the diagnostic performance at the overall and the enamel caries threshold. The other methods showed fair to excellent discrimination at the overall caries threshold (NIRT 0.64, LF 0.89 and ACIS 0.86) and acceptable discrimination at the dentin caries threshold (NIRT 0.82, LF 0.81 and ACIS 0.79). AUROC for enamel caries exhibited the weakest discrimination. Accuracy was 65.6% for VE, 69.8% for BWR, 50.0% for NIRT, 53.1% for LF and 74.0% for ACIS. Reliability assessment for BWR and NIRT showed at least substantial agreements for all analyses. Conclusions The methods, NIRT, LF and ACIS, revealed different potential but no impeccable performance for occlusal caries detection. All are suitable instruments to detect hidden carious lesion in dentin. As auxiliaries to VE, LF and ACIS showed an increase in diagnostic performance.


2008 ◽  
Vol 24 (3) ◽  
pp. 295-300 ◽  
Author(s):  
Michele Baffi Diniz ◽  
Jonas de Almeida Rodrigues ◽  
Andréia Bolzan de Paula ◽  
Rita de Cássia Loiola Cordeiro

2016 ◽  
Vol 28 (6) ◽  
pp. 654-661 ◽  
Author(s):  
Angel Insua ◽  
Alberto Monje ◽  
Hsun-Liang Chan ◽  
Nouf Zimmo ◽  
Lujain Shaikh ◽  
...  

2021 ◽  
Vol 16 (2) ◽  
pp. 113-126
Author(s):  
Ilham Wan Mokhtar ◽  
Annapurny Venkiteswaran ◽  
Mohd Yusmiaidil Putera Mohd Yusof

Dental caries is a commonly progressive disease that proceeds through various degrees of severity that a dentist can detect. The aims of the in vivo study were to assess the accuracy of the individual model (near-infrared light transillumination [NILT] device, visual and radiographic examinations) in detecting occlusal caries, and to evaluate the performance of visual and NILT device combination for occlusal caries detection in deciding the treatment options. Fifty-two non-cavitated occlusal surfaces from 16 patients were assessed with three different diagnostic devices in random order. Identified lesions were prepared and validated. Logistic regression analysis was performed for each method. The sensitivity and specificity values for each method and the combined models were statistically measured using RStudio version 0.97.551. At the enamel level, visual detection was the most sensitive method (0.88), while NILT was the most specific (0.93). NILT scored the highest for sensitivity (0.93) at the dentine level and visual detection scored the highest for specificity (0.88). Visual detection + NILT model was significantly better (p = 0.04) compared to visual detection or NILT alone (df = 1). The visual-NILT combination is a superior model in detecting occlusal caries on permanent teeth. The model provided surplus value in caries detection hence improving the treatment decision-making in occlusal surfaces.


Author(s):  
Vasili Popozoglo ◽  
◽  
Vasile Zagnat ◽  

The basic paraclinical method of diagnosis in dentistry is the radiological examination. It is constantly used in therapeutic dentistry – in diagnosis and in the treatment process. The analysis of the literature and comparative study have concluded that out of all the radio-diagnostic methods, cone beam computed tomography (CBCT) is the most effective in determining periapical destructive diseases. In this study we aimed to confirm this moment based on our own clinical data. Conclusions: 1) The radiological examination gives us information on the shape, size and structure of periapical lesions and different methods of investigation give us different degrees of veracity of the results. 2) The comparative analysis of the effectiveness of radiological examination methods of patients with periapical destruction showed that CBCT is the most informative method of imaging examination compared to orthopantography and periapical radiographs.


Sign in / Sign up

Export Citation Format

Share Document