SP5.2.4 Stent-graft endobypass for non-infected femoral pseudoaneurysms in high-risk surgical patients: acceptable short-to-mid-term results

2021 ◽  
Vol 108 (Supplement_7) ◽  
Author(s):  
Arindam Chaudhuri ◽  
Ramita Dey ◽  
Weronika Stupalkowska

Abstract Aim Stent-grafts are finding a place in the treatment of femoral pseudoaneurysms (FpsAs), having been described in the treatment of infected pseudoaneurysms. We present the results of endovascular treatment of non-infected FpsAs using stent-grafts. Methods Case series of patients who underwent stent-graft coverage of FpsAs from January 2016 to December 2020. Stent-graft fractures, occlusions and reinterventions, length of stay (LOS) and 30-day mortality were assessed. Results 11 patients (mean age 75±10.3 years, 7 males; all ASA 3 or 4) underwent stent-graft coverage of FpsAs. Original procedures linked to the formation of FpsA were iliofemoral bypass (n = 3), femorofemoral crossover (n = 3), percutaneous coronary interventions (n = 2), aortobifemoral bypass (n = 1), endovascular aneurysm repair (n = 1) and femoral endarterectomy (n = 1). 3 patients had previous open FpsA repair. Technical success of deployment was 100%. Stent-grafts used included Viabahn Endoprosthesis (WL Gore & Associates, Flagstaff USA; n = 8), Viabahn VBX (WL Gore & Associates; n = 1) and BeGraft (Bentley InnoMed GmbH, Hechingen, Germany; n = 2). All patients were maintained on either antiplatelets or anticoagulant. 10 patients were available for analysis (1 lost to follow-up); radiological follow-up included initial computed tomography angiography and later combined duplex ultrasonography/plain radiography. Median LOS was 4 days (IQR 4). 30-day mortality was 0%. Median survival was 12 months (IQR 17). There was one stent-graft occlusion requiring thrombectomy but no fractures were observed in this series. Conclusions This small series suggests that there may be a role for stent-grafts in treatment of FpsAs in carefully selected patients. Given lack of data on long-term outcomes, continued surveillance is recommended.

2018 ◽  
Vol 26 (1) ◽  
pp. 72-75
Author(s):  
Fabien Lareyre ◽  
Claude Mialhe ◽  
Carine Dommerc ◽  
Juliette Raffort

Purpose: To report the use of the Nellix endovascular aneurysm sealing (EVAS) system in the management of proximal stent-graft collapse associated with thrombosis following endovascular aneurysm repair (EVAR). Case Report: A 76-year-old man was admitted for proximal collapse of an aortic extension following bifurcated AFX stent-graft implantation associated with chimney grafts in both renal arteries and the superior mesenteric artery 1 month prior. Imaging identified thrombosis of the aortic stent-graft and the iliac limbs. A Nellix EVAS was placed into the AFX stent-graft to recanalize the aneurysm lumen and address the aortic thrombosis. There was no endoleak, and the renovisceral chimney stent-grafts remained patent over a follow-up of 25 months. Conclusion: While further studies are required to generalize its use, EVAS appears to be feasible in the management of aortic stent-graft collapse.


2019 ◽  
Vol 53 (6) ◽  
pp. 515-519
Author(s):  
Toshiya Nishibe ◽  
Toru Iwahashi ◽  
Kentaro Kamiya ◽  
Masaki Kano ◽  
Keita Maruno ◽  
...  

We present 3 cases of type IIIb endoleak after endovascular aneurysm repair (EVAR) using the Zenith stent graft system. Type III endoleak, like type I endoleak, is a high-pressure, high-risk leak that increases sac pressure up to or even above arterial pressure, and is associated with an increased frequency of open conversions or risk of aneurysm rupture. Type IIIb endoleak is rare but there is much concern that the incidence of type IIIb endoleak is likely to increase hereafter; the mechanism of type IIIb endoleak is deterioration of graft fabric in conjunction with stent sutures. Type IIIb endoleak is difficult to diagnose before rupture. The possibility of type IIIb endoleak should be highly suspected when the continued growth of an excluded aneurysm sac without direct radiologic evidence is observed during follow-up. Type IIIb endoleak can be repaired by relining of the stent graft with additional stent grafts.


2020 ◽  
Vol 27 (3) ◽  
pp. 462-467
Author(s):  
Konstantinos Tigkiropoulos ◽  
Kyriakos Stavridis ◽  
Ioannis Lazaridis ◽  
Evangelos Bontinis ◽  
Ioulia Zournatzi ◽  
...  

Purpose: To report outcomes of elective endovascular aneurysm repair (EVAR) using the Anaconda stent-graft in a tertiary vascular center. Materials and Methods: A retrospective study was conducted of 271 patients (mean age 71.5 years; 260 men) who underwent elective EVAR for abdominal aortic aneurysm using the Anaconda stent-graft from January 2006 to January 2017. Median aneurysm diameter was 58 mm (range 50–90). All patients were anatomically suitable for EVAR according to the 2003 version of the instructions for use. Follow-up included computed tomography angiography at 1, 6, and 12 months and yearly thereafter for the first 4 years and then every 2 years. Primary outcomes included technical success and 30-day aneurysm-related mortality and complications; secondary outcomes were overall and aneurysm-related mortality and aneurysm-related morbidity in follow-up. Results: The Anaconda stent-graft was implanted successfully in all patients. Primary and secondary technical success rates were 99.6% and 100%, respectively. Three patients (1.1%) died within 30 days of causes unrelated to the aneurysm, while 15 patients (5.5%) suffered perioperative complications. Median follow-up was 72 months (range 14–141). The overall type I endoleak rate was 4.7% (11 proximal, 2 distal). Late aneurysm-related complications were observed in 48 patients (17.3%); aneurysm-related mortality was 1.4% (n=4). Non-aneurysm-related mortality was 21.0% (n=57). Freedom from reintervention was 95.2% at 1 year, 98% at 2 years, and 90% at 6 years. There was no significant difference in the overall limb graft occlusion rate between the second- and third-generation devices. Conclusion: Results in our cohort study demonstrate that the Anaconda stent-graft has satisfactory early and late results with low aneurysm-related mortality.


2018 ◽  
Vol 25 (4) ◽  
pp. 492-498 ◽  
Author(s):  
Sonia Ronchey ◽  
Stefano Fazzini ◽  
Salvatore Scali ◽  
Giovanni Torsello ◽  
Paul Kubilis ◽  
...  

Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). Overall, 70 visceral vessels were targeted for revascularization. Results: Technical success was achieved in 35 (89.7%) cases; 3 persistent type Ia endoleaks and 1 chimney graft occlusion were detected within the first 30 days. Thirty-day mortality was 2.6%. Two other deaths (not aneurysm related) occurred during a mean follow-up of 21.9 months (0.23–71.3). Primary patency of the chimney grafts was 94.3% at 36 months. In a subgroup analysis comparing Endurant to other stent-grafts, no significant differences were observed regarding persistent endoleak [1/20 (5%) vs 2/19 (11%), p=0.6] or reintervention [1/20 (5%) vs 0/19 (0%)]. Conclusion: The present series demonstrates that chEVAR in the treatment of post-EVAR type Ia endoleaks has satisfactory results independent of the abdominal and chimney graft combinations. Midterm results show that chEVAR is an effective method for treating type Ia endoleaks.


2007 ◽  
Vol 14 (5) ◽  
pp. 672-675 ◽  
Author(s):  
Philipp Geisbüsch ◽  
Hardy Schumacher ◽  
Jochen Hansmann ◽  
Jens-Rainer Allenberg ◽  
Dittmar Böckler

Purpose: To report late abdominal aortic aneurysm (AAA) rupture after endovascular stent-graft repair despite complete thrombotic stent-graft occlusion. Case Report: A 65-year-old man underwent successful endovascular aneurysm repair (EVAR) with a Stentor device in 1995. In the interim course, the patient developed complete thrombotic stent-graft occlusion, which was treated with an axillobifemoral bypass. After 8 years, the patient presented with a reperfused and ruptured infrarenal AAA. Open repair was performed, with a good clinical result and exclusion of the AAA. Conclusion: Thrombosed stent-grafts and aneurysms can transmit systemic arterial pressure and cause late rupture. Lifelong surveillance is mandatory in EVAR patients.


2009 ◽  
Vol 137 (1-2) ◽  
pp. 10-17 ◽  
Author(s):  
Lazar Davidovic ◽  
Momcilo Colic ◽  
Igor Koncar ◽  
Dejan Markovic ◽  
Dusan Kostic ◽  
...  

Introduction. Endovascular aneurysm repair (EVAR) has been introduced into clinical practice at the beginning of the 90's of the last century. Because of economic, political and social problems during the last 25 years, the introduction of this procedure in Serbia was not possible. Objective. The aim of this study was to present preliminary experiences and results of the Clinic for Vascular Surgery of the Serbian Clinical Centre in Belgrade in endovascular treatment of thoracic and abdominal aortic aneurysms. Methods. The procedure was performed in 33 patients (3 female and 30 male), aged from 42 to 83 years. Ten patients had a descending thoracic aorta aneurysm (three atherosclerotic, four traumatic - three chronic and one acute as a part of polytrauma, one dissected, two penetrated atherosclerotic ulcers), while 23 patients had the abdominal aortic aneurysm, one ruptured and two isolated iliac artery aneurysms. The indications for EVAR were isthmic aneurismal localisation, aged over 80 years and associated comorbidity (cardiac, pulmonary and cerebrovasular diseases, previous thoracotomy or multiple laparotomies associated with abdominal infection, idiopatic thrombocitopaenia). All of these patients had three or more risk factors. The diagnosis was established using duplex ultrasonography, angiography and MSCT. In the case of thoracic aneurysm, a Medtronic-Valiant? endovascular stent graft was implanted, while for the abdominal aortic aneurysm Medtronic-Talent? endovascular stent grafts with delivery systems were used. In three patients, following EVAR a surgical repair of the femoral artery aneurysm was performed, and in another three patients femoro-femoral cross over bypass followed implantation of aortouniiliac stent graft. Results. During procedure and follow-up period (mean 1.6 years), there were: one death, one conversion, one endoleak type 1, six patients with endoleak type 2 that disappeared during the follow-up period, one early graft thrombosis. No other complications, including aneurysm expansion, collapse, deformity and migration of the endovascular stent grafts, were registered. Conclusion. According to all medical and economic aspects, we recommend EVAR to treat acute traumatic thoracic aortic aneurysm, as well as in elderly and high-risk patients with abdominal or thoracic aneurysms, when open surgery is related to a significantly higher mortality and morbidity.


2013 ◽  
Vol 54 (1) ◽  
pp. 54-58 ◽  
Author(s):  
Thomas Nyheim ◽  
Lars Erik Staxrud ◽  
L Rosen ◽  
Carl Erik Slagsvold ◽  
Gunnar Sandbæk ◽  
...  

Background Simplifying a postoperative surveillance protocol for endovascular aneurysm repair (EVAR) requires quality control comparing computerized tomography (CT) and ultrasound (US) results of abdominal aortic aneurysm (AAA) diameter measurements and endoleaks. Purpose To test if US is comparable to CT, then assess a simplified follow-up with our conventional surveillance to assess patient safety. Material and Methods During 2001-2006, data on 56 patients treated with Talent stent graft were prospectively registered. Median follow-up was 41.5 months (range, 2-94 months), with CT, US, and plain film abdomen X-rays (PFA) at 1, 6, and 12 months, then yearly. Bland-Altman plot was used to assess the agreement between CT and US measuring the AAA diameters and mixed model by the time effect to assess the difference in diameter over time. Sensitivity and specificity for detection of endoleaks by US, with CT as ‘gold standard’ were calculated. A simplified surveillance protocol with US/PFA at 6 and 8 weeks, CT/US/PFA at 1 year, and yearly US/PFA thereafter, was evaluated. CT was carried out when poor visibility, endoleak detected, AAA diameter increase (≥5 mm) on US or migration (≥10 mm) on PFA. This regime was compared with our conventional follow-up protocol. Results Diameter measurements on US appear comparable to CT with 91% specificity and 85% sensitivity for endoleaks detected by US. Using the simplified surveillance protocol no endoleaks, migrations, or endotension requiring treatment were overlooked. The simplified protocol generated 53 selective CT scans, avoiding approximately 144 CT scans. If further simplified by omitting the 1-year CT scan, one type II endoleak would be missed with a 1-year delay, eliminating a further 45 CT scans. Conclusion US appears comparable to CT in the follow-up of Talent stent grafts in our institution. The proposed simplified surveillance protocol seems safe and can lead to a significant reduction in the number of CT scans.


2020 ◽  
Vol 27 (6) ◽  
pp. 910-916
Author(s):  
Konstantinos Spanos ◽  
Tilo Kölbel ◽  
Martin Scheerbaum ◽  
Konstantinos P. Donas ◽  
Martin Austermann ◽  
...  

Purpose: To compare the outcomes of iliac branch devices (IBD) used in combination with standard endovascular aneurysm repair (EVAR) vs with fenestrated/branched EVAR (f/bEVAR) to treat complex aortoiliac aneurysms. Materials and Methods: The pELVIS Registry database containing the outcomes of IBD use at 8 European centers was interrogated to identify all IBD procedures that were combined with either standard EVAR or f/bEVAR. Among 669 patients extracted from the database, 629 (mean age 72.1±8.8 years; 597 men) had received an IBD combined with standard EVAR vs 40 (mean age 71.1±8.0 years; 40 men) who underwent f/bEVAR with an IBD. The mean aortic aneurysm diameters were 46.4±13.3 mm in the f/bEVAR patients vs 45.0±15.5 mm in the standard EVAR cases. The groups were similar in terms of baseline clinical characteristics and aneurysm morphology. The Kaplan-Meier method was used to compare patient survival, IBD occlusion, type III endoleak, and aneurysm-related reinterventions in follow-up. The estimates are presented with the 95% confidence interval (CI). Results: Technical success was 100% in the f/bEVAR+IBD group and 99% in the EVAR+IBD group (p=0.85). The 30-day mortality was 0% vs 0.5%, respectively (p=0.66), while the 30-day reintervention rates were 7.5% vs 4.1% (p=0.31). The mean follow-up was 32.1±21.3 months for f/bEVAR+IBD patients (n=30) and 35.5±26.8 months for EVAR+IBD patients (n=571; p=0.41). The 12-month survival estimates were 93.4% (95% CI 93.2% to 93.6%) in the EVAR+IBD group vs 93.6% (95% CI 93.3% to 93.9%) for the f/bEVAR+IBD group (p=0.93). There were no occlusions or type III endoleaks in the f/bEVAR+IBD group at 12 months, while the estimates for freedom from occlusion and from type III endoleak in the EVAR+IBD group were 97% (95% CI 96.8% to 97.2%) and 98.5% (95% CI 98.4% to 98.6%), respectively. The 12-month estimates for freedom for aneurysm-related reintervention were 93% (95% CI 92.7% to 93.3%) in the EVAR+IBD group vs 86.4% (95% CI 85.9% to 86.9%) in the f/bEVAR+IBD patients (p=0.046). Conclusion: Treatment of complex aortoiliac disease with f/bEVAR+IBD can achieve equally good early and 1-year outcomes compared to treatment with IBDs and standard bifurcated stent-grafts, except for a somewhat higher reintervention rate in f/bEVAR patients.


Vascular ◽  
2008 ◽  
Vol 16 (5) ◽  
pp. 253-257 ◽  
Author(s):  
Evert J. Waasdorp ◽  
Joost A. van Herwaarden ◽  
Rob H.W. van de Mortel ◽  
Frans L. Moll ◽  
Jean-Paul P.M. de Vries

This study evaluated the value of computed tomographic angiography (CTA) early after an endovascular aneurysm repair (EVAR) in relation to CTA 3 months after EVAR. We retrospectively reviewed all elective EVAR patients with available postprocedural and 3-month follow-up CTAs who were treated between 1996 and 2006. CTAs were analyzed for EVAR-related complications in terms of endoleaks, migration, and stent graft thrombosis. Secondary procedures and other complications within a 4-month time interval after EVAR were noted and analyzed for any association with the postprocedural CTA. During the study period, 291 patients (275 men), with a mean age of 71 years, underwent elective EVAR. All had postprocedural and 3-month follow-up CTAs, which detected 93 (32%) endoleaks (8 type I, 84 type II, 1 type III) and 1 stent graft thrombosis. These findings resulted in four secondary interventions (one interposition cuff, two extension cuffs, one conversion). All reinterventions were successfully done in an elective setting. During the first 3 postoperative months, five other reinterventions were required for acute ischemia in four patients (three Fogarty procedures, one femorofemoral crossover bypass) or groin infection in one patient. Eight patients died, but none of the deaths were related to abdominal aortic aneurysm or EVAR (four cardiac, two pulmonary, one gastric bleeding, one carcinoma). At 3 months, 43 endoleaks (3 type I, 40 type II), 3 stent graft thromboses, and 1 stent graft migration were seen. In two patients (0.7%), a new endoleak was diagnosed compared with the postprocedural CTAs. In 287 (99%) of 291 patients, the postprocedural CTA did not influence our treatment policy in the first 3 months after EVAR. More than half of the early endoleaks were self-limiting, and new endoleaks were seen in only two patients (< 1%) at the 3-month follow-up CTA. After an uneventful EVAR procedure, it is safe to leave out the early postprocedural CTA.


2021 ◽  
Vol 9 (B) ◽  
pp. 1494-1498
Author(s):  
Mohamed Hosny Sayed ◽  
Mohammed Ali Hassan ◽  
Ahmed Samir Hosny ◽  
Hisham Rashid ◽  
Mohamed Hosni El Dessoki

BACKGROUND: The availability of aortic stent-grafts has permitted an obvious change in the management of abdominal aortic aneurysms (AAA). For elective cases open surgical repair has been widely superseded by the use of stent-graft. With the rapid evolution of the endovascular technology, a significant development in stent-graft techniques was achieved in conjunction with a better understanding of how to utilize stent-grafts. METHODS: A multicenter prospective study in which 49 patients were enrolled, they underwent an elective endovascular aneurysm repair (EVAR) procedure for infrarenal AAA in two different institutions, Kasr Al-ainy School of Medicine, Cairo University and King’s College Hospital in London, the selected patients were followed up for 6 months after the procedure. Data relating to demographics and pre-operative comorbidities were recorded. Aneurysm morphology was reviewed by computed tomography angiography scans. Clinical data was collected through operative records and afterward through outpatient clinic follow-up sessions. RESULTS: Overall survival was 94% over a period of 6 months calculated using KaplanMeier Survival Curve. CONCLUSIONS: Endovascular repair resulted in fewer perioperative deaths. This study provides insight into clinical parameters that can be used to stratify patients’ post-EVAR surveillance and need for re-intervention and it came to the conclusion that EVAR could be considered as the standard repair for uncomplicated infrarenal AAA.


Sign in / Sign up

Export Citation Format

Share Document