scholarly journals Stability-Indicating Reversed-Phase UHPLC Method Development and Characterization of Degradation Products of Almotriptan Maleate by LC-QTOF-MS/MS

2017 ◽  
Vol 56 (1) ◽  
pp. 6-17
Author(s):  
B Saibaba ◽  
Ch Vishnuvardhan ◽  
P Johnsi Rani ◽  
N Satheesh Kumar
2015 ◽  
Vol 39 (8) ◽  
pp. 6303-6314 ◽  
Author(s):  
Pradipbhai D. Kalariya ◽  
Prinesh N. Patel ◽  
R. Srinivas ◽  
M. V. N. Kumar Talluri

Systematic method development was performed for dolutegravir and its stress degradation products. Structural elucidation of all degradants was carried out.


2017 ◽  
Vol 100 (4) ◽  
pp. 1029-1037 ◽  
Author(s):  
Liang Zou ◽  
Lili Sun ◽  
Hui Zhang ◽  
Wenkai Hui ◽  
Qiaogen Zou ◽  
...  

Abstract The characterization of process-related impurities and degradation products of safinamide mesilate (SAFM) in bulk drug and a stability-indicating HPLC method for the separation and quantification of all the impurities were investigated. Four process-related impurities (Imp-B, Imp-C, Imp-D, and Imp-E) were found in the SAFM bulk drug. Five degradation products (Imp-A, Imp-C, Imp-D, Imp-E, and Imp-F) were observed in SAFM under oxidative conditions. Imp-C, Imp-D, and Imp-E were also degradation products and process-related impurities. Remarkably, one new compound, identified as (S)-2-[4-(3-fluoro-benzyloxy) benzamido] propanamide (i.e., Imp-D), is being reported here as an impurity for the first time. Furthermore, the structures of the aforementioned impurities were characterized and confirmed via IR, NMR, and MS techniques, and the most probable formation mechanisms of all impurities proposed according to the synthesis route. Optimum separation was achieved on an Inertsil ODS-3 column (250 × 4.6 mm, 5 μm), using 0.1% formic acid in water (pH adjusted to 5.0) and acetonitrile as the mobile phase in gradient mode. The proposed method was found to be stability-indicating, precise, linear, accurate, sensitive, and robust for the quantitation of SAFM and its process-related substances, including its degradation products.


2020 ◽  
Vol 11 (1) ◽  
pp. 781-789
Author(s):  
Sriram Valavala ◽  
Nareshvarma Seelam ◽  
Subbaiah Tondepu ◽  
Suresh Kandagatla

The present study aims to develop a simple, accurate and specific stability-indicating RP-HPLC technique for the analysis of metoclopramide in the presence of its stress degradation products and characterization of degradation compounds by LC-MS/MS analysis. As per ICH Q1A-R2 guidelines, the drug was exposed to acid hydrolytic stress condition. Three degradation products were formed for MCP in acid hydrolysis. The liquid chromatography was processed on a Luna C18-(2) 100A,250×4.6mm 5micron column using an isocratic mobile phase consisting of 0.1% formic acid in water-acetonitrile (20:80, v/v) by adjusting the mobile phase at 1 ml/min flow rate with wavelength detection at 273 nm. The developed procedure was applied to LC-MS/MS (liquid chromatography-tandem mass spectrometry) for the characterization of all the degradant components. Total new three degradation compounds were recognized and identified by LC-MS/MS. The developed RP-HPLC technique was validated as per the ICH Q2-R1 guidelines. Limit of detection and limit of quantification values of MCP were evaluated from the linearity graph and were found to be 5.23 µg/ml and 17.44 µg/ml. Accuracy study was established at 80.0, 100.0 and 120.0 µg/ml concentration levels and the findings were found in the range of 98.4% - 101.8%. The linearity of the technique was assessed over the drug concentration range of 50.0 µg/ml to 250.0 µg/ml and the regression equation, slope and correlation coefficient values were found to be y = 10618x + 1623.2, 10618 and 0.9996 respectively. The developed technique was uninterruptedly applied for the quantification of metoclopramide inactive pharmaceuticals.


2018 ◽  
Vol 101 (4) ◽  
pp. 1021-1029
Author(s):  
Priyanka Maheshwari ◽  
Neelima Shukla ◽  
Manish Kumar Dare

Abstract A stability-indicating isocratic reversed-phase ion-pair chromatographic method was designed for the separation of impurities in the presence of degradation products. Marbofloxacin tablets and a placebo were exposed to the stress conditions of oxidative, acid, base, humidity, thermal, and photolytic degradation. Significant and moderate degradation was observed in acidic and oxidative stress conditions, respectively. The degradation products were well resolved from the main peak and its impurities, thus proving the stability-indicating analytical method. The method was developed by using an XTerra RP18 3.5 μm (150 × 4.6 mm) column, with the mobile phase containing a mixture of buffer (pH 2.5)–methanol–glacial acetic acid (77 + 23 + 0.5, v/v). The flow rate of the mobile phase was 1.2 mL/min, with a column oven temperature of 40°C and a detection wavelength of 315 nm. The proposed method met Veterinary International Conference on Harmonization requirements and was successfully used for impurity quantitation in marbofloxacin tablets.


Sign in / Sign up

Export Citation Format

Share Document