A high-performance liquid-chromatographic method for routine simultaneous determination of nicotine and cotinine in plasma.

1988 ◽  
Vol 34 (4) ◽  
pp. 724-729 ◽  
Author(s):  
M Hariharan ◽  
T VanNoord ◽  
J F Greden

Abstract We describe a rapid, sensitive method for the routine simultaneous determination of nicotine and cotinine in 1 mL of plasma. Extraction in 10-mL screw-capped Teflon tubes with methylene chloride after deproteinization with trichloroacetic acid eliminated emulsion formation. The extract, after evaporation and reconstitution in 30 microL of mobile phase, is injected into a reversed-phase C-18 ion-pair column of an isocratic high-performance liquid-chromatographic unit. Absorbance is monitored at 256 nm. The mobile phase is a citrate-phosphate (30 mmol each per liter) buffer mixture containing 50 mL of acetonitrile and 1 mmol of sodium heptanesulfonate per liter. 2-Phenylimidazole is the internal standard. The detection limit is 1 microgram/L for nicotine and 3 micrograms/L for cotinine. The standard curve is linear from 0 to 700 micrograms/L for both compounds. The average CV for nicotine in the concentration range 0-100 micrograms/L is 6.5%, and that for cotinine in the concentration range 50-700 micrograms/L is 4%.

1983 ◽  
Vol 29 (10) ◽  
pp. 1840-1842 ◽  
Author(s):  
J Lehmann ◽  
H L Martin

Abstract We have adapted to erythrocytes a method for the determination of alpha- and gamma-tocopherols in plasma and platelets. Erythrocytes (50 microL) were extracted with methanol containing tocol (internal standard) and pyrogallol. Tocopherols were partitioned into chloroform, washed, and injected in methanol onto a reversed-phase (C18) "high-performance" liquid-chromatographic column. The mobile phase was methanol/water (99/1 by vol) at a flow rate of 2 mL/min and detection was with a "high-performance" spectrophotofluorometer. The limit of detection for either tocopherol is 0.10 microgram/mL of packed cells. Analytical recoveries ranged from 93 to 104%. Some values for tocopherols in human erythrocytes are presented.


2008 ◽  
Vol 91 (2) ◽  
pp. 344-348 ◽  
Author(s):  
Shweta Sadanand Sabnis ◽  
Nilesh Dnvandev Dhavale ◽  
Vijay Yeshawantrao Jadhav ◽  
Santosh Vilashchand Gandhi

Abstract A new, simple column reversed-phase high-performance liquid chromatographic (HPLC) method for simultaneous determination of rabeprazole sodium (RAB) and domperidone (DOM) in a combined tablet dosage form has been developed and validated. Determination was performed using a Jasco HPLC system with a HiQ SiL octadecylsilane (C18) column (250 4.6 mm id), acetonitrile0.1 M ammonium acetate (50 + 50, v/v) mobile phase, and paracetamol as an internal standard. The detection was performed using a UV detector set at 280 nm. The method was validated with respect to linearity, accuracy, precision, and robustness. Beer's law was obeyed in the concentration range of 1.010.0 and 0.55.0 g/mL for RAB and DOM, respectively. The method has been successfully applied for the analysis of drugs in a pharmaceutical formulation.


2007 ◽  
Vol 4 (1) ◽  
pp. 109-116 ◽  
Author(s):  
K. Basavaiah ◽  
B. C. Somashekar

A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS) in bulk drug and in tablets. FNS was eluted from a ODS C18reversed phase column at laboratory temperature (30 ± 2°C) with a mobile phase consisting of methanol and water (80+20) at a flow rate of 1 mL min-1with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1with limits of detection (LOD) and quantification (LOQ) being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV) ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.


1984 ◽  
Vol 30 (7) ◽  
pp. 1228-1230 ◽  
Author(s):  
A K Dhar ◽  
H Kutt

Abstract This method for determination of haloperidol in plasma is based on "high-performance" isocratic liquid chromatography with the use of a C8 bonded reversed-phase column at room temperature. Haloperidol and the internal standard (chloro-substituted analog) are extracted from alkalinized plasma into isoamyl alcohol/heptane (1.5/98.5 by vol) and back-extracted into dilute H2SO4. The aqueous phase is directly injected onto the column. The mobile phase is a 30/45/25 (by vol) mixture of phosphate buffer (16.5 mmol/L, pH 7.0), acetonitrile, and methanol. Unlike other liquid-chromatographic procedures for haloperidol, commonly used psychotropic drugs do not interfere. Analysis can be completed within an hour. The procedure is extremely sensitive (1.0 microgram/L) and is well reproducible (CV 5.6% for a 2.5 micrograms/L concentration in plasma).


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


1981 ◽  
Vol 27 (3) ◽  
pp. 437-440 ◽  
Author(s):  
D R Uges ◽  
P Bouma

Abstract We have developed "high-performance" liquid-chromatographic methods for determining 4-aminopyridine, an acetylcholine-releasing drug, in serum, saliva, and urine. As little as 1 microgram/L can be detected by extracting the alkalinized sample plus the internal standard (3,4-diaminopyridine) into dichloromethane, mixing the organic phase with 1-pentanol, evaporating the dichloromethane, and injecting the residue onto a reversed-phase column, where it is eluted with acetonitrile/methanol/aqueous ammonium carbonate, with detection at 245 nm. Analytical recoveries from serum averaged 86.7%. The CV at 50 micrograms/L was 2.9% (n = 8). For urine samples containing very high concentrations of 4-aminopyridine, we mixed urine and potassium carbonate in an automatic injector vial, extracted the drug into dichloromethane, centrifuged, and injected an aliquot of the extract into the chromatograph. Analytical recoveries averaged 92%, and the CV was about 2% for drug concentrations of 0.1-8 mg/L of urine.


1979 ◽  
Vol 25 (7) ◽  
pp. 1300-1302 ◽  
Author(s):  
S H Petersdorf ◽  
V A Raisys ◽  
K E Opheim

Abstract We describe the use of "high-performance" liquid chromatography to measure chloramphenicol in as little as 25 microL of serum. Serum is treated to precipitate proteins with acetonitrile containing p-nitroacetanilide as an internal standard. Chloramphenicol is eluted with a mobile phase of methanol in pH 7.0 phosphate buffer (35/65 by vol). The drug is measured at 278 nm and simultaneously monitored at 254 nm; interfering substances are detected by examining the 278 nm/254 absorbance ratios. This method is sensitive to less than 0.5 mg/L and the standard curve is linear to at least 50 mg/L. Inter-day precision ranged between 3--6%. We encountered no interference from endogenous compounds or from other drugs we tested.


2013 ◽  
Vol 49 (3) ◽  
pp. 521-528 ◽  
Author(s):  
Viviane Benevenuti Silva ◽  
Angel Arturo Gaona Galdos ◽  
Cintia Maria Alves Mothe ◽  
Michele Bacchi Pallastrelli ◽  
Maria Segunda Aurora Prado ◽  
...  

A simple, rapid, economical and reliable high performance liquid chromatographic method has been developed and successfully applied in simultaneous determination of ethinyl estradiol and drospirenone in coated tablets. The HPLC method was performed on a LiChroCART® 100RP column (125x4 mm i.d., 5 µm) with acetonitrile:water 50:50 (v/v) as mobile phase, pumped at a flow rate of 1.0 mL.min-1. The fluorescence detection for ethinyl estradiol was made at λex= 280 nm and λem= 310 nm and a UV detection for drospirenone was made at 200 nm. The elution time for ethinyl estradiol and drospirenone were 4.0 and 5.7 min, respectively. The method was validated in accordance to USP 34 guidelines. The proposed HPLC method presented advantages over reported methods and is suitable for quality control assays of ethinyl estradiol and drospirenone in coated tablets.


1988 ◽  
Vol 34 (9) ◽  
pp. 1897-1899 ◽  
Author(s):  
M H Cheng ◽  
W Y Huang ◽  
A I Lipsey

Abstract This high-performance liquid-chromatographic (HPLC) method for simultaneous determination of prednisone and its metabolite, prednisolone, in plasma is a modification of the method of Frey et al. (Clin Chem 1979;25:1944-7). Heparinized plasma (1.0 mL) with 0.1 mL of internal standard solution (11-deoxy-17-hydroxycorticosterone, 2 mg/L) is extracted with 7.0 mL of dichloromethane, then washed sequentially with 0.1 mol/L HCl, 0.1 mol/L NaOH, and deionized water, 2.0 mL each. The extract is evaporated and the residue reconstituted with 75 microL of mobile phase, methanol/H2O (40/60 by vol). Thirty microliters of this is injected onto a reversed-phase C6 column, which is eluted at 1.4 mL/min. Analytical recoveries of prednisone and prednisolone were 94-98% and 102-106%, respectively. Day-to-day precision (CV) was 3.8% for prednisone, 6.1% for prednisolone. We encountered no interference from the 21 other steroids and 25 drugs tested. This method is simple, accurate, and precise.