Minimal fluoroscopy approach in current clinical practice with a novel ablation technology for supraventricular tachycardia: a large multicenter experience from an Italian registry

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Anselmino ◽  
F.M Cauti ◽  
A Piro ◽  
N Di Belardino ◽  
M Scaglione ◽  
...  

Abstract Background Electrophysiological studies and ablation procedures expose both physicians and patients to a large amount of radiation. Most of 3-D mapping systems provide improved tracking of catheters, possibly allowing relevant reductions in radiation exposure. No data exists on the ability of the Rhythmia mapping system to minimize fluoroscopy time and dose. Purpose To report preliminary data on feasibility and safety of a minimal fluoroscopic approach using the Rhythmia mapping system in supraventricular tachycardia (SVT) procedures. Methods Consecutive patients indicated for arrhythmia ablation were enrolled in the CHARISMA study at 12 centers. For our purpose consecutive right-side procedures performed through a minimal fluoroscopy approach with the Rhythmia mapping system were analyzed. A 3D geometry of chambers of interest was reconstructed on the basis of the electroanatomic information taken from the mapping system. Fluoroscopy was used only if deemed necessary. Results This analysis included 266 patients (mean age = 57±17 years, 57% male) undergoing SVT procedures (120 AVNRT, 91 AFL, 32 AP, 11 AT and 12 other right atrial procedures). In all cases, diagnostic EP and ablation catheters were positioned using a low fluoroscopic electroanatomic guided approach. The mean fluoroscopy time needed for each procedure was 55±128 s. The median reconstructed RA volume was 92 [63–131] ml in a median mapping time of 11 [7–17] min. The median number of radiofrequency ablations to terminate each arrhythmia was 6 [3–12] (total RF delivery time of 291 [180–505] s). Sixty-five percent of the procedures (n=174) were completed with less than 10 s of fluoroscopy. Low fluoroscopy approach with less than 10 s (minimal fluoroscopy approach) was most frequently obtained in case of AVNRT (91, 76%) compared to other arrhythmias' ablation (83, 57%, p=0.001) Achievement of a minimal fluoroscopic approach was not affected by operator's experience (65% vs 66%, p=1.00, respectively within physician with more or less of 10 years of active practice), whereas it was affected by presence of a fellow in training during the procedure (72% without fellow vs 26% with fellow, p<0.0001). A 100% rate of acute success was observed, and no procedure-related complications occurred. At multivariate logistic regression analysis adjusted for baseline confounders, both the total number of RF ablations (OR: 0.93 (95% CI:0.88 to 0.96; p=0.0053) and the presence of a fellow in training during the procedure (OR: 0.29; 95% CI: 0.1 to 0.87; p=0.0278) had an inverse association to the achievement of a minimal fluoroscopic approach. Conclusions In our preliminary experience, arrhythmias' ablation through minimal fluoroscopy approach with the use of a novel ablation technology seems to be safe, feasible, and effective in common right atrial arrhythmias. Use of fluoroscopy can be dramatically reduced in most cases, without any reduction of the safety and acute effectiveness profile. Funding Acknowledgement Type of funding source: None

EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
F M Cauti ◽  
A Piro ◽  
N Di Belardino ◽  
G Tola ◽  
M Anselmino ◽  
...  

Abstract Funding Acknowledgements NO FUNDING Background Electrophysiological studies and ablation procedures expose both physicians and patients to a significant amount of radiation. Nowadays, most of 3-D mapping systems allow for improved tracking of catheters with possible reduction in radiation exposure. No data exists on the ability to minimize fluoroscopy time and dose while using the Rhythmia mapping system. Purpose To report preliminary data on feasibility and safety of a low fluoroscopic approach using the Rhythmia mapping system in SVT procedures. Methods The CHARISMA study is a non-randomized, multicenter, prospective study in which consecutive patients indicated for arrhythmia were enrolled. For our purpose consecutive right-side procedures performed through a low fluoroscopy approach with the Rhythmia mapping system were analyzed. The mapping system was used to create the 3D geometry of chambers of interest and anatomic reference points and to visualize the catheters from the beginning to the end of the procedure. Fluoroscopy was used only if deemed necessary. Results 204 unselected consecutive cases of SVT from 11 centers were included in the study (mean age = 55 ± 18 years, 53% male, 85 AVNRT, 75 AFL, 28 AP, 9 AT and 7 other right atrial procedures). In all the cases, diagnostic EP and ablation catheters were positioned using only the low fluoroscopic guided mapping approach. During the study, a total of 7157 s of fluoroscopy was needed in 204 patients (51 ± 137 s per procedure). One hundred fourty-one procedures (69%) were completed with less than 10 seconds of fluoroscopy, whereas in 169 (83%) of the cases the fluoroscopy time was lower than 60 seconds. Low fluoroscopy approach with less than 10 seconds was less frequently obtained in case of AFL (46, 61.3%) compared to AVNRT ablation (65, 76.5%, p = 0.041) whereas no differences were found comparing with AP (21, 75%, p = 0.248). The median reconstructed RA volume was 94[65-133] ml in a median mapping time of 11 [6-16] min. The median number of radiofrequency ablations to terminate each arrhythmia was 5 [3-12] (total RF delivery time of 293 [180-505] sec). A 100% rate of acute success was observed in our case series. No complications occurred. Conclusions In our preliminary experience, arrhythmias ablation through low fluoroscopy approach and the use of a novel ablation technology seems to be safe, feasible, and effective in common right atrial arrhythmias. Use of fluoroscopy can be nearly avoided in most cases, without any reduction of the safety and effectiveness profile.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
C La Greca ◽  
FM Cauti ◽  
A Piro ◽  
N Di Belardino ◽  
M Anselmino ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background Limited data exist on factors associated with radiation exposure during ablation procedures when a high definition mapping technology is used. Purpose To report factors associated with radiation exposure and data on feasibility and safety of a minimal fluoroscopic approach using the Rhythmia mapping system in supraventricular tachycardia (SVT) ablation procedures. Methods Consecutive patients indicated for arrhythmia ablation were enrolled in the CHARISMA study at 12 centers. We included in this analysis consecutive right-side procedures performed through a minimal fluoroscopy approach with the Rhythmia mapping system were analyzed. A 3D geometry of chambers of interest was reconstructed on the basis of the electroanatomic information taken from the mapping system. Fluoroscopy was used only if deemed necessary. The effective dose (ED) was calculated using accepted formula. For our purpose high dose exposure was defined as an ED greater than the median value of ED of the population exposed to radiation. Results This analysis included 325 patients (mean age = 56 ± 17 years, 57% male) undergoing SVT procedures (152 AVNRT, 116 AFL, 41 AP and 16 AT). During the study, 27481 seconds of fluoroscopy was used (84.6 ± 224 seconds per procedure), resulting in a mean equivalent ED of 1.1 ± 3.7 mSv per patient. The mean reconstructed RA volume was 99 ± 54 ml in a mean mapping time of 12.2 ± 7 min. The mean number of radiofrequency ablations (RFC) to terminate each arrhythmia was 9.4 ± 9 (mean RFC delivery time equal to 6.7 ± 6 min). 192 procedures (59.1%) were completed without any use of fluoroscopy; during the remaining 133 procedures (39.9%), 206.6 ± 313.4 seconds of fluoroscopy was used (median ED = 1.2 mSv). In a minority of the cases (n = 25, 7.7%) the fluoroscopy time was higher than 5 minutes (median ED = 6.5 mSv), whereas radiologic exposure time greater than 1 minute occurred in ninety cases (27.7%, median ED = 2.1 mSv). On multivariate logistic analysis adjusted for baseline confounders the RFC application time (OR = 1.0014, 95%CI: 1.0007 to 1.0022; p = 0.0001) was independently associated to an ED greater than 1.2 mSv, whereas female gender had an inverse association (0.54, 0.29 to 0.98; p = 0.0435). Acute success was reached in 97.8% of the cases. During a mean of 290.7 ± 169.6 days follow-up, no major adverse events related to the procedure were reported. Overall, the recurrence rate of the primary arrhythmia during follow-up was 2.5%. Conclusions In our experience, arrhythmias ablation through minimal fluoroscopy approach with the use of a novel ablation technology is safe, feasible, and effective in common right atrial arrhythmias. High-dose exposure occurred in a very limited number of cases, without any reduction of the safety and acute and long-term effectiveness profile.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
D Lin ◽  
B Glover ◽  
J Colley ◽  
B Thibault ◽  
C.M Steinberg ◽  
...  

Abstract Background The EnSite Precision™ Cardiac Mapping System is a catheter navigation and mapping system capable of displaying the three-dimensional (3D) position of conventional and sensor enabled electrophysiology catheters, as well as displaying cardiac electrical activity as waveform traces and dynamic 3-D maps of cardiac chambers. Objective The EnSite Precision™ Observational Study was designed to quantify and characterize the use of the EnSite Precision™ Cardiac Mapping System for mapping and ablation of cardiac arrhythmias in a real-world environment and to evaluate procedural and subsequent clinical outcomes. Methods 1065 patients were enrolled at 38 centers in the U.S. and Canada between 2017–2018. Eligible subjects were adults undergoing a cardiac electrophysiology mapping and radiofrequency ablation procedures using the EnSite Precision™ System. Results Of 989 patients who completed the protocol, a geometry was created in 936 (94.7%). Most initial maps were created using Automap (n=545, 67.0%) or a combination of Automap and manually mapping (n=151, 18.6%). Median time to create an initial map was 9.0 min (IQR 5.0–15.0), with a median number of used mapping points per minute of 92.7 (IQR 30.0–192.0). During ablation, AutoMark was used in 817 (82.6%) of procedures. The most frequent metrics for lesion color were Impedance Drop or Impedance Drop Percent (45.5% combined), time (23.9%) and average force (14.2%). At Canadian sites where LSI was an option, it was used as the color metric in 87 (45.8%) of cases (10.6% overall). The EnSite System was stable throughout 79.7% (n=788 of 989) of procedures. Factors affecting stability were respiratory change (n=88 of 989, 8.9%), patient movement (n=73, 7.4%), CS Positional Reference dislodgement (n=32, 3.2%), and cardioversion (n=19, 1.9%). Conscious sedation was used in 189 (19.1%) of patients. Acute success was reached based on the pre-defined endpoints for the procedure in 97.4% (n=963) of cases. Conclusion In a real-world study analysis, the EnSite Precision™ mapping system was associated with a high prevalence of acute procedural success, low mapping times, and high system stability. Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A L Parreira ◽  
P Carmo ◽  
P Adragao ◽  
S Nunes ◽  
J Pinho ◽  
...  

Abstract Introduction and aims The 12-lead ECG is highly inaccurate for localization of the site of origin of supraventricular and ventricular arrhythmias.  Non-invasive mapping systems (ECGI) based on a high number of electrodes recording the electrical activity on the surface of the torso have already proven good accuracy for mapping different arrhythmic substrates. The aim of this study was to assess what is the minimal number of leads needed to obtain a precise mapping with the ECGI. Methods This study enrolled 14 patients (9 male, median age 50 (44-58) years) referred to our center for catheter ablation of premature ventricular contractions (PVC). Patients underwent pre-procedural ECGI using the epicardial and endocardial mapping system . This system uses the DICOM images from contrast computed tomography of the heart and up to 28 adhesive electrodes with 8 leads each, adding up to 224 body-surface leads. All patients underwent invasive electroanatomical mapping and ablation with the magnetic navigation system. We analysed the number of recording leads used to construct the non-invasive activation map of the PVCs and the accuracy and the spatial resolution of the map when comparing to the invasive map. We then reprocessed the exam, using progressively less leads until we only left the leads placed in the standard 12 lead ECG positions and evaluated the concordance with the invasive map as well as the spatial resolution. We considered an earliest activation site (EAS) area of 1 cm2 a good spatial resolution and using a ROC curve we calculated the minimal number of leads necessary to obtain a good spatial resolution. Results The median number of electrodes used for the initial map was 170 (138-177). Concordance between non-invasive and invasive site of origin occurred in 11 out of 14 patients. The results are presented in the Table. The minimal number of electrodes to have a good spatial resolution was 100. The area of EAS was significantly lower when using more than 100 leads, respectively 0.65 (0.5-1) cm2 versus 3 (1.6-5) cm2, p < 0.001. Conclusions The minimal number of leads to achieve a good spatial resolution was high.  Reducing the number of leads resulted in a significant decrease in spatial resolution and a lower concordance rate. ECGI data Number of adhesive electrodes Median number of leads Amycard/Carto concordance Median area of EAS in the ECGI (cm2) Maximal nº electrodes 170 (138-177) 11/14 0.64 (0.5-0.9) 12 electrodes 76 (61-80) 11/14 1.6 (1.4-2.6) 6 electrodes (2 Ant, 2 Lat ,2 Post) 38 (32-44) 9/14 4.3 (3.2-5.4) 12 leads 12 0/14 - Ant anterior; Lat: lateral; Post: posterior; EAS: early activation site. Abstract Figure. Area of EAS according to the N of leads


2019 ◽  
Vol 3 (3) ◽  
Author(s):  
Jin-Yi Li ◽  
Xiang-Wei Lv ◽  
Guo-Qiang Zhong ◽  
Hong-Hong Ke

Abstract Background Micro-reentry tachycardia usually emerges in scar tissues related to post-atrial fibrillation ablation and cardiomyopathy. It is difficult to identify the micro-reentry circuit accurately by conventional mapping method. Case summary A 74-year-old man presented with paroxysmal atrial tachycardia (AT) presenting as palpitations. He was evaluated by an electrophysiological examination using a high-density CARTO mapping system. The mapping results showed the AT with a cycle length of 184 ms was focused on his right atrial fossa ovalis (FO). In this small area, the high-density mapping demonstrated a significant micro-reentrant tachycardia. Radiofrequency ablation at the centre of the micro-reentrant circuit successfully terminated the AT. No recurrences were observed during a 12-month follow-up. Discussion This case demonstrated a micro-reentrant AT originates from the FO without cardiomyopathy or previous ablation with specific loops. This is an unusual location for AT though and can cause difficulty for operators if it terminates or is non-sustained. High-density mapping using a PentaRay catheter can effectively characterize micro-reentrant circuits and determine the real target for ablation therapy.


2005 ◽  
Vol 94 (4) ◽  
pp. 510-518 ◽  
Author(s):  
Seija I. Oikarinen ◽  
Anne-Maria Pajari ◽  
Irma Salminen ◽  
Satu-Maarit Heinonen ◽  
Herman Adlercreutz ◽  
...  

Flaxseed is a dietary source of possible chemopreventive compounds such as lignans and α-linolenic acid (ALA). To study the effects of a flaxseed mixture on adenoma formation in multiple intestinal neoplasia mice, the mice were fed a diet containing 2·7 % flaxseed, 4·5 % fibre and 3·7 % ALA. To elucidate the effect of oils of the mixture we also composed a diet without flaxseed but with the same oil composition. The median number of adenomas in the small intestine was fifty-four for the control group, and thirty-seven (P=0·023) and forty-two (P=0·095) for flaxseed and oil groups, respectively. Compared with controls (1·2 mm), the adenoma size was smaller in the flaxseed (0·9 mm; P=0·002) and oil (1·0 mm; P=0·012) groups. Both diets changed the proportions of n-3 and n-6 fatty acids in the colonic mucosa. Membrane β-catenin and protein kinase C (PKC)-ζ levels were reduced in the adenoma v. mucosa (P<0·05), and an inverse association was found between the membrane PKC-ζ in the mucosa and the adenoma number (r −0·460, P=0·008, n 32). Only the flaxseed diet increased lignan levels in the caecum (P=0·002) and in plasma (P=0·002) but they were not associated with tumour formation. The results suggest that the preventive effect of flaxseed on colon carcinogenesis may be due to the oil part of flaxseed, and the loss of β-catenin and PKC-ζ from the membranes of the mucosal tissue may play a permissive role in intestinal tumour development.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
M Pope ◽  
P Kuklik ◽  
A Briosa E Gala ◽  
MICHAEL Mahmoudi ◽  
J O H N Paisey ◽  
...  

Abstract Introduction Interatrial propagation has been widely studied in anatomical specimens and electrophysiological studies during sinus rhythm or pacing. However, pathways of conduction during atrial fibrillation (AF) are poorly characterised in vivo. Purpose We sought to develop a method of identifying the dominant channel of communication between atria during AF with a view to characterising the role of localised mechanisms in maintaining AF between both chambers. Methods 10 patients undergoing simultaneous bi-atrial non-contact charge density mapping before and following pulmonary vein isolation (PVI) were analysed. Simultaneous 30s recordings during AF were obtained. Virtual electrograms from every vertex of the reconstructed left and right atrial (LA, RA) anatomies were exported and phase calculated using a method of sinusoidal recomposition and Hilbert transform. For each vertex, coherence between a sequence of activations between this point and every other point on the opposing chamber was calculated using mean phase coherence (MPC). The maximum of all MPC values was assigned to this local point to estimate the degree of coherence between activity at a given point and the entire opposing chamber. The regions with highest MPC value represent the channel of communication. Each activation of this zone is then evaluated and difference in local activation time between LA and RA determined (figure). Communication between atria is determined where a normal distribution of timing shift within this channel can be demonstrated (as opposed to a uniform histogram in the case of a lack of any correlation between electrograms). If seen to be preceding the opposite chamber for ≥60% of the recording then the chamber was deemed to be leading. Results A total of 18 maps were obtained (pre-PVI only in 2). A clear channel of interatrial propagation could be seen in 17 maps (MPC value 0.48 ± 0.16) with communication within this channel demonstrated in 13 of these (MPC 0.52 ± 0.16). In the RA the most common site was in the posterior inter-caval zone (in 13) and on the posterior septum of the LA (in 14). The LA was leading in 4 maps and the RA in 2 with balanced propagation in 7. Conclusion The method of average MPC identifies channels of inter-atrial communication during AF which appear to predominantly involve posterior interatrial connections. Further application of this technique to characterise interatrial propagation may help to define patient specific phenotypes of AF and guide targeted therapy. Abstract Figure 1


1988 ◽  
Vol 95 (4) ◽  
pp. 643-650 ◽  
Author(s):  
Atsushi Harada ◽  
Harry J. D'Agostino ◽  
Richard B. Schuessler ◽  
John P. Boineau ◽  
James L. Cox

2017 ◽  
Vol 7 (2) ◽  
pp. 61
Author(s):  
William C. W. Huang ◽  
Yi-MeiJoy Lin ◽  
Ching Che J. Chiu ◽  
Chia-Huei Chiu ◽  
Fu-Sheng Chang

Purpose: This study was to investigate whether there is an age dependent effect on the association between ADIPPOR1 SNP and hypertriglyceridemia for each gender.Materials and Methods: 116 individuals aged 20 and above who claimed to be healthy were enrolled and grouped into male and female populations. Blood samples were taken to determine hypertriglyceridemia and genomic variants. Sample t-tests were performed for basic comparison. To ascertain the contribution of genetic variants and age to lipid metabolism, a multivariate logistic regression analysis was conducted to identify the correlates for hypertriglyceridemia adjusting for life styles.Results: For males, individuals with hypertriglyceridemia tended to be younger (p-value=0.02), less stressed (0.05), and have a higher proportion of ADIPOR1 minor allele carriers (0.03). However, no significant differences were found in age, stress, diet, and genetic variances in females. In regression analysis, males showed age-gene correlation with 1.5 times higher detection of hypertriglyceridemia risk when both factors were considered. In contrast, females showed no correlation between age-gene. In addition, age was positively associated with hypertriglyceridemia in females while males showed an inverse association.Conclusion: Our findings presented data that suggests age may be a contributing factor to the association between ADIPOR1 and hypertriglyceridemia in males while age showed a significant inverse association with hypertriglyceridemia. Thus, age-gene correlation may be implied during primary practice to encourage lifestyle adjustments by screening for ADIPOR1 SNP minor allele carriers to prevent cerebrovascular disease in males.


Sign in / Sign up

Export Citation Format

Share Document