First clinical experience with the wearable cardiac rhythm long-term monitoring cardioskin device

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
P Guedeney ◽  
J Silvain ◽  
F Hidden-Lucet ◽  
C Maupain ◽  
S Dinanian ◽  
...  

Abstract Background There are only limited options for long-term cardiac monitoring devices readily available in clinical practice for outpatients. Holter monitoring devices are limited by the uncomfort of wires and patches, the small number of leads for analysis, the quality of recordings or the monitoring duration while insertable cardiac monitors are costly and exposed to potential local complication. Purpose To describe a single center experience with a novel wearable device for cardiac rhythm monitoring. Methods The Cardioskin™ system is a patch-free, wire-free, wearable device with rechargeable batteries that provides a high quality 15-lead electrocardiogram monitoring over 1 month (Figure 1). Data are sent using a mobile application downloaded in the patient smartphone to a central Corelab where they can be interpreted by an expert and/or the prescribing physician. An alarm signal is readily available within the Cardioskin™ device, to allow patients to indicate the presence of symptoms. In this single center retrospective registry, we provide a first report of the use of this novel device in real world practice, with indication and duration of cardiac monitoring left at the physicans “discretion”. Results From January 2019 to December 2019, the Cardioskin™ system was prescribed in 60 patients for an overall median duration of 26.5 (14–32) days. The mean age of the patients was 45±12.2 years and 24 (40%) were male. Indications for cardiac monitoring were post-Stroke, palpitation, syncope and cardiomyopathy assessment in 56%, 30%, 7% and 7% of the cases, respectively. A sustained (>30 seconds) supraventricular tachycardia was detected in 4 cases, including one case of atrial fibrillation, two case of atrial tachycardia and on case of junctional tachycardia. Unsustained ventricular tachycardia and atrial fibrillation burst were detected in another 2 cases (Figure 1). There was no reported case of skin irritation by the Cardioskin™ system or abrupt interruption of the monitoring by the patients. Conclusion The Cardioskin™ system is a novel, discreet and comfortable cardiac rhythm wearable long-term monitoring device which can be used in clinical practice for broad diagnostic indications. Figure 1. Cardioskin system Funding Acknowledgement Type of funding source: Public Institution(s). Main funding source(s): ACTION coeur

2017 ◽  
Vol 40 (11) ◽  
pp. 1044-1048 ◽  
Author(s):  
Rachel M. Kaplan ◽  
Paul D. Ziegler ◽  
Jodi Koehler ◽  
Taya V. Glotzer ◽  
Rod S. Passman

PEDIATRICS ◽  
1979 ◽  
Vol 63 (4) ◽  
pp. 670-673
Author(s):  
Dorothy H. Kelly ◽  
Kathleen O'Connell ◽  
Daniel C. Shannon

Infants who have experienced an episode of prolonged sleep apnea associated with cyanosis, pallor, and limpness requiring vigorous stimulation or mouth-to-mouth resuscitation to restore breathing, are at risk of experiencing a recurrence that may result in death1.2. The American Academy of Pediatrics has recommended that such infants be treated by 24-hour surveillance either in the home or in the hospital. Electronic monitoring devices "may be useful adjuncts" to such surveillance.3 Since 1973, we have monitored 270 infants at home with apnea or cardiac monitors. A major problem with monitoring infants at home has been false alarms, such as alarms for apnea when the infant is breathing, on heart rate or apnea alarms due to a loose electrode.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
C Mannina ◽  
Z Jin ◽  
K Matsumoto ◽  
K Ito ◽  
A Biviano ◽  
...  

Abstract Background Prolonged monitoring of cardiac rhythm has been used in patients with symptomatic arrhythmias and to assess for atrial fibrillation (AF) after cryptogenic stroke, but not in the general population and especially in older adults. Purpose To evaluate the frequency of arrhythmias in a community-based cohort of older adults through 14-days continuous cardiac monitoring using a patch-based device. Methods Cardiac rhythm was analyzed in 533 participants free of AF and congestive heart failure (CHF) from the tri-ethnic (white, black, Hispanic) Subclinical Atrial Fibrillation and Risk of Ischemic Stroke (SAFARIS) study. AF, supraventricular tachycardia (SVT, defined as 4 beats or more), premature atrial (PACs) and ventricular (PVCs) contractions, ventricular tachycardia (VT, defined as 4 beats or more), sinus pauses (SP) and atrio-ventricular blocks (AVB) were analyzed. Gender, age and race-ethnic differences were examined. Results Mean age was 77.2±6.8 years (198 men, 335 women). Recording duration was over 10 days in 91%, and over 13 days in 84%. AF was present in 10 participants (1.9%), atrial flutter in 1 (0.2%). Other arrhythmias are reported in the Table. SP (1.9%) and high-degree AVB (Mobitz II: 0.6%; 3rd degree: 0.9%) were rare. No significant race-ethnic differences were observed. Conclusion In older adults without history of stroke or CHF, prolonged rhythm monitoring revealed moderate frequency of AF, but higher than expected frequencies of AF-predisposing conditions such as SVT and frequent PACs. VT episodes were relatively frequent, whereas SP and AVB were less frequent than commonly believed. Most arrhythmias were more frequent in the oldest; ventricular arrhythmias were more common in men than in women. Funding Acknowledgement Type of funding source: Public grant(s) – National budget only. Main funding source(s): NINDS R01 NS083874


2021 ◽  
Vol 8 (7) ◽  
pp. 81
Author(s):  
Andrzej Kułach ◽  
Milena Dewerenda ◽  
Michał Majewski ◽  
Anetta Lasek-Bal ◽  
Zbigniew Gąsior

Introduction: Silent atrial fibrillation (AF) is a common cause of cryptogenic ischemic stroke (CIS). The 24-h-Holter is insufficient to reveal an occult arrhythmic cause of stroke and the strategy to select the patients for long-term monitoring is missing. Objectives: The aim of the study was to evaluate 7-day-Holter monitoring to identify cases with the arrhythmic cause of stroke in CIS patients in whom 24-h-Holter was free from arrhythmia, and to assess the relation between supraventricular (SV) runs in baseline Holter and the incidence of AF in a 3-year follow-up period. Methods: 78 patients (aged 60 ± 9 years, 45 males) with CIS and no arrhythmic findings in 24-h-Holter were enrolled. All patients had 7-day-Holter monitoring after stroke and were followed up for 36 months, and then 7-day Holter was repeated. We assessed SV runs (≥5 QRS) in the initial 7-day Holter and analyzed the relation of the findings with clinical characteristics of novel AF episodes revealed early after stroke and during a 3-year follow-up. Results: Baseline 7-day-Holter revealed SV runs in 36% of patients and AF in 9% of cases. During a 3-year follow-up, 8 additional cases were confirmed, both in standard care and in repeated Holter (a total of 19% of AF cases). There was no difference with regard to CHADS2VASc score (3.6 ± 1.1 vs. 3.4 ± 1.5; p = NS) and left atrium parameters between patients with SV runs and the non-arrhythmic group. Patients with SV runs had a higher incidence of AF both after stroke and in a 3-year follow-up (46% vs. 4%, RR 11.6, p < 0.001). In 8 cases, patent foramen ovale was detected during follow-up. Conclusions: A strategy of baseline 7-day-Holter monitoring after stroke allows for disclosing SV runs in every third case and AF in 9% of stroke survivors. Patients with SV runs have a higher incidence of AF (RR 11.6, p < 0.001) and should be considered for extended continuous ECG monitoring.