Care of Reverse Phase High Performance Liquid Chromatographic Columns When Injecting Extracts of Fat- or Oil-Based Preparations

1981 ◽  
Vol 64 (5) ◽  
pp. 1258-1258
Author(s):  
Fredric M Rabel

Abstract When analyzing extracts of pharmaceutical preparations, the chromatographer may place some of the base fats or oils onto the reverse phase analytical column with each injection. This is not a problem if they are washed free from the column periodically. If not cleaned off the column, column efficiency and selectivity can be lost forever. A simple procedure is described for washing columns.

INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


2019 ◽  
Vol 87 (4) ◽  
pp. 31 ◽  
Author(s):  
Makoni ◽  
Chikukwa ◽  
Khamanga ◽  
Walker

An isocratic high-performance liquid chromatographic method using electrochemical detection (HPLC-ECD) for the quantitation of clarithromycin (CLA) was developed using Response Surface Methodology (RSM) based on a Central Composite Design (CCD). The method was validated using International Conference on Harmonization (ICH) guidelines with an analytical run time of 20 min. Method re-validation following a change in analytical column was successful in reducing the analytical run time to 13 min, decreasing solvent consumption thus facilitating environmental and financial sustainability. The applicability of using the United States Pharmacopeia (USP) method scaling approach in place of method re-validation using a column with a different L–designation to the original analytical column, was investigated. The scaled method met all USP system suitability requirements for resolution, tailing factor and % relative standard deviation (RSD). The re-validated and scaled method was successfully used to resolve CLA from manufacturing excipients in commercially available dosage forms. Although USP method scaling is only permitted for columns within the same L-designation, these data suggest that it may also be applicable to columns of different designation.


1983 ◽  
Vol 66 (3) ◽  
pp. 663-666
Author(s):  
Ijaz Ahmad

Abstract A simple and fast analytical method is described for the quantitative determination of low levels of paraquat residues in water. The method involves extraction and concentration of paraquat in water by using a C18 Sep-Pak cartridge followed by reverse phase high performance liquid chromatographic determination with ultraviolet detection at 257 nm. Recoveries of paraquat from spiked samples were above 93% with a coefficient of variation of 6.1%. The method can be used for water samples with paraquat concentrations as low as 0.05 ppm.


Author(s):  
T Hemant Kumar ◽  
CH. ASHA ◽  
D. GOWRI SANKAR

Objective: To develop and validate a simple, specific, accurate, precise and sensitive reverse phase high performance liquid chromatographic (RP-HPLC) method with forced degradation studies for the simultaneous estimation of amlodipine besylate and irbesartan in the pharmaceutical formulation. Methods: The chromatographic separation of the two drugs were achieved using Enable C 18G column (250 ×4.6 mm; 5 µm) in isocratic mode with mobile phase consisting of sodium acetate buffer (pH 4.0) and acetonitrile (30:70, % v/v) with a flow rate of 0.6 ml/min. Ultraviolet(UV) detection was carried out at 238 nm. The proposed method was validated for linearity, range, accuracy, precision, robustness, limit of detection (LOD) and limit of quantification (LOQ). The tablet formulation was subjected to stress conditions of degradation including acidic, alkaline, oxidative, thermal and photolysis. Results: The retention time for amlodipine besylate and irbesartan were found to be 5.512 and 6.321 min respectively. Linearity was observed over a concentration range 4-32 µg/ml for amlodipine besylate (r2 =0.9999) and 10-70 µg/ml for Irbesartan (r2 =0.9998). The % relative standard deviation (RSD) for Intraday and Interday precision was found to be 0.436 and 0.699 for amlodipine besylate and 0.435 and 0.30 for irbesartan. Amlodipine besylate shown stability towards acidic and thermal whereas in basic, oxidative and photolytic it shown less stability in which it degraded to more extent. Irbesartan shown stability towards thermal conditions whereas in remaining conditions it degrades to more extent especially in oxidative conditions. Conclusion: The developed reverse phase high performance liquid chromatographic (RP-HPLC) method was also found to be simple, precise and sensitive for the simultaneous determination of amlodipine besylate and irbesartan in the tablet dosage form.


1981 ◽  
Vol 64 (4) ◽  
pp. 889-892
Author(s):  
Badaruddin Shaikh ◽  
Margarette R Hallmark

Abstract Methapyrilene hydrochloride (MP·HCl) was extracted from feed with methanol and determined by reverse phase partition chromatography in less than 15 min, using isocratic elution with acetonitrile-1.1% ammonium carbonate (1 + 1) as the mobile phase. This procedure was tested on feed treated with MP·HCl at levels of 125,500, and 2000 ppm. Recoveries were 104,95, and 96% with coefficients of variation of 2.4,1.6, and 0.6%, respectively. MP·HCl in feed was stable for 14 days. This method was also successfully used to determine MP·HCl in 3 sleep aid tablets.