scholarly journals Determination of Semicarbazide in Baby Food by Liquid Chromatography/Tandem Mass Spectrometry: Interlaboratory Validation Study

2006 ◽  
Vol 89 (3) ◽  
pp. 728-734 ◽  
Author(s):  
Richard Ginn ◽  
Lesley Wilson ◽  
Scheilla V C De Souza ◽  
Maria B Dela Calle ◽  
J Barbosa ◽  
...  

Abstract An interlaboratory validation study funded by the European Commission, Directorate General for Health and Consumer Protection (DG SANCO), was conducted to evaluate the effectiveness of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of semicarbazide (SEM) in different types of baby food at a possible future European regulatory limit (10 ng/g). The test portion of the sample was extracted with hydrochloric acid, and the analyte was derivatized with 2-nitrobenzaldehyde, with 1,2-[15N2, 13C] SEM as an internal standard. The extract was neutralized and then purified on a solid-phase extraction cartridge. The SEM was determined by reversed-phase LC with detection by MS/MS. Apple puree, rice pudding, and meat/vegetable meal baby food materials, spiked with SEM at levels of about 3, 10, and 30 ng/g, respectively, were sent to 20 laboratories in 12 different European countries, which submitted results from 17 participants. Recoveries ranged from 88.8 to 106.1%. Based on results for spiked samples (blind pairs at 3 levels), the relative standard deviations for repeatability (RSDr) ranged from 4.2 to 6.9% and the relative standard deviations for reproducibility (RSDR) ranged from 16.6 to 24.3%. The method showed acceptable within- and between-laboratory precision for all 3 matrixes, as evidenced by HorRat values, at the target levels for the determination of SEM.

Molecules ◽  
2020 ◽  
Vol 25 (5) ◽  
pp. 1254 ◽  
Author(s):  
Won-Gu Choi ◽  
Dong Kyun Kim ◽  
Yongho Shin ◽  
Ria Park ◽  
Yong-Yeon Cho ◽  
...  

Doxorubicin, an anthracycline antitumor antibiotic, acts as a cancer treatment by interfering with the function of DNA. Herein, liquid chromatography-tandem mass spectrometry was for the first time developed and validated for the simultaneous determination of doxorubicin and its major metabolites doxorubicinol, doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The liquid–liquid extraction of a 10 μL mouse plasma sample with chloroform:methanol (4:1, v/v) and use of the selected reaction monitoring mode led to less matrix effect and better sensitivity. The lower limits of quantification levels were 0.5 ng/mL for doxorubicin, 0.1 ng/mL for doxorubicinol, and 0.01 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone. The standard curves were linear over the range of 0.5–200 ng/mL for doxorubicin; 0.1–200 ng/mL for doxorubicinol; and 0.01–50 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The intra and inter-day relative standard deviation and relative errors for doxorubicin and its four metabolites at four quality control concentrations were 0.9–13.6% and –13.0% to 14.9%, respectively. This method was successfully applied to the pharmacokinetic study of doxorubicin and its metabolites after intravenous administration of doxorubicin at a dose of 1.3 mg/kg to female BALB/c nude mice.


2017 ◽  
Vol 80 (12) ◽  
pp. 2112-2118 ◽  
Author(s):  
Dan Hu ◽  
Xu Xu ◽  
Tian Cai ◽  
Wei-Ying Wang ◽  
Chun-Jie Wu ◽  
...  

ABSTRACTA rapid and sensitive analytical method based on high-performance liquid chromatography–tandem mass spectrometry was developed and validated for the determination of isopyrazam (IZM) and azoxystrobin (AZT) in cucumbers. A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method was used as the pretreatment procedure. The samples were extracted with acetonitrile and cleaned up with octadecylsilyl silica (C18) and graphite carbon black. The proposed method resulted in satisfactory recovery of IZM and AZT (91.48 to 114.62%), and relative standard deviations were less than 13.1% at fortification concentrations of 1, 20, and 500 μg kg−1 (n = 3). The limits of quantification for IZM and AZT were 0.498 and 0.499 μg kg−1, respectively, which are far below the maximum residue level (0.5 mg kg−1) established for this type of sample. Matrix effects were also evaluated. This study established a sensitive and fast method for the detection of IZM and AZT in cucumber samples.


Molecules ◽  
2020 ◽  
Vol 25 (19) ◽  
pp. 4399
Author(s):  
Dasom Shin ◽  
Hui-Seung Kang ◽  
Hyungsoo Kim ◽  
Guiim Moon

In this work, liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed and validated for screening and confirmation of 64 illicit compounds in dietary supplements. The target compounds were illegally used pharmaceutical drugs, prohibited compounds, and not authorized ingredients for different therapeutics (sexual enhancement, weight loss, muscular strengthening, and relaxing products). The validation procedure was performed to evaluate selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was >0.98 in the range of 0.5–200 µg L−1. The LOQs were in the range 1–10 µg kg−1 for all target compounds. The accuracy (expressed as recovery) was 78.5–114%. The precision (expressed as the relative standard deviation) was below 9.15%. The developed method was applied for the determination of illicit compounds in dietary supplements collected from websites. As a result, the total detection rate was 13.5% (27 samples detected in 200 samples). The concentrations of detected samples ranged from 0.51 to 226 mg g−1. The proposed methodology is suitable for monitoring the adulteration of illicit compounds in dietary supplements.


2014 ◽  
Vol 852 ◽  
pp. 266-269
Author(s):  
Xiao Fang Wang ◽  
Chun Liang Yang ◽  
Mao Fang Huang ◽  
Ming Yue Wang ◽  
Yu Bing Zha ◽  
...  

The conditions for detecting residues of diflubenzuron in vegetables by ultra high performance liquid chromatography tandem mass spectrometry were studied. The target was extracted with acetonitrile for 2 min with a homogenizer. The extaction was purifide by a conditioned Florisil SPE cartridge, and then was detected by ultra high-performance liquid chromatography with tandem mass spectrometry. The average recovery was in the range from 87.8 %- 99.2 % at spike levels of 0.1, 1.0 and 10 mg/kg in vegetables, and relative standard deviations was in the range of 4.2 %-8.9 %. The proposed method is fast, simple, sensitive and accurate.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Dinh-Vu Le ◽  
Trong-Tuan Nguyen ◽  
Van-Trong Nguyen

A liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been validated for the simultaneous determination of methamphetamine (MA) and 3,4-methylenedioxy-N-methamphetamine (MDMA) in the blood sample. Under the optimal experimental conditions, the concentration of MA can be determined in the range from 1 µg/L to 5000 µg/L with the method detection limit (MDL) of 0.31 µg/L. The range from 0.5 to 500 µg/L is observed for the determination of MDMA with the MDL down to 0.25 µg/L. The practical applicability of the method is performed with the recovery ranging from 85.3% to 94% for MA and from 86.9% to 95.5% for MDMA. At the different concentrations of drugs, the relative standard deviations (RSD) for both MA and MDMA are lower than 5.7%. The method was applied to analyse 1995 blood samples that had been collected from the Forensic Medicine Centre of Ho Chi Minh City. The results showed 1.75% positive with MA and 0.25% positive with MDMA. These two drugs take 10% of the total drugs positive samples. By using deuterium-labelled methamphetamine-d5 and 3,4-methylenedioxy-N-methamphetamine-d5 as the internal standards in the determination and the use of MS/MS in multiple reaction monitoring mode signal readout, the method exhibits robustness specificity and can be applied in simultaneous determination of MA and MDMA in blood with high selectivity and sensitivity.


2006 ◽  
Vol 89 (3) ◽  
pp. 786-796 ◽  
Author(s):  
Dieter Zimmer ◽  
Christiane Philipowski ◽  
Birgit Posner ◽  
Agnes Gnielka ◽  
Edgar Dirr ◽  
...  

Abstract This paper describes a selective and sensitive method that uses liquid chromatography/tandem mass spectrometry with positive electrospray ionization (ESI+) for the determination of deltamethrin in a variety of crops. Samples were extracted by conventional high-speed blending. Some samples required no further cleanup; others were cleaned up by gel permeation chromatography, strong cation-exchange cartridges, or partitioning with n-hexane. In the determinative step, the buffered neutral mobile phase, consisting of 10 mM ammonium acetate (pH 6.8) and methanol, and ESI+ provided strong ammonium adduct formation to [M+NH4]+ at m/z 523, and the multiple-reaction monitoring (MRM) transition at m/z 523/281 was used for the quantitation of deltamethrin. A second MRM transition at m/z 525/283 was used for confirmation. The limit of quantitation (LOQ) values were 0.01 mg/kg for edible materials and 0.05 mg/kg for nonedible materials. Mean overall recoveries at the LOQ and the 10-fold LOQ ranged from 73 to 96%, and the relative standard deviations were <10% for all samples materials analyzed.


2009 ◽  
Vol 92 (1) ◽  
pp. 348-358 ◽  
Author(s):  
Limin He ◽  
Donghao Zhao ◽  
Yijuan Su ◽  
Yahong Liu ◽  
Jianrong Nie ◽  
...  

Abstract A robust, credible, and practical multiresidue method based on liquid chromatography/tandem/mass spectrometry (LC/MS/MS) was developed for the simultaneous determination of 9 macrocyclic lactone drugs (abamectin B1a, doramectin, erythromycin, ivermectin B1a, josamycin, kitasamycin, roxithromycin, tilmicosin, and tylosin A) in bovine, porcine, chicken, and sheep muscles. The drugs were extracted with acetonitrile, and the extracts were defatted with n-hexane and further cleaned up on a C18 solid-phase extraction cartridge. LC/MS/MS data acquisition was achieved by using the multiple-reaction monitoring (MRM) mode, i.e., 2 transitions, to provide a high degree of sensitivity and repeatability. Matrix-matched standard calibration curves were used to achieve the best accuracy of the method by compensating for the matrix effect. The calibration graphs were linear (r >0.998) from 10 to 1000 ng/mL for erythromycin, josamycin, kitasamycin, roxithromycin, tilmicosin, and tylosin, and from 5 to 250 ng/mL for abamectin, doramectin, and ivermectin. The average recoveries of the 9 drugs were between 64.5 and 105, calculated by using matrix-matched calibration, with relative standard deviation values ranging from 1.6 to 14. The limits of detection were 0.1 g/kg for erythromycin, josamycin, roxithromycin, and tylosin; 0.2 g/kg for tilmicosin and kitasamycin; and 0.5 g/kg for abamectin, doramectin, and ivermectin. For confirmation, the MRM ratios for the 9 drug residues in the samples and the solvent were evaluated and found to be within the ratio criteria set by the guidelines of the European Union.


Separations ◽  
2020 ◽  
Vol 7 (3) ◽  
pp. 44
Author(s):  
Linda Okšová ◽  
Peter Tölgyessy

A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS) was proposed for the determination of α-, β-, and γ-hexabromocyclododecane (HBCD) diastereomers in whole-fish homogenate samples. The main modification of the QuEChERS method concerned a clean-up step in which the combination of pH-tuned dispersive liquid–liquid microextraction (DLLME) with 18.4 M H2SO4 digestion allowed to successfully eliminate the matrix substances from the final extract. For the target HBCDs, good response linearity was obtained with coefficients of determination (R2) >0.998 for the concentration range corresponding to 0.1–50 ng of analyte per g of sample. Limits of quantifications (LOQs) were 0.15–0.25 ng g−1 ww (wet weight), and the recoveries from samples spiked at levels of 0.5 and 5 ng g−1 ranged from 89% to 102% with relative standard deviations <7.5%. The accuracy of the method was verified by analysis of the NIST standard reference material SRM 1947, and a good agreement (90%) was obtained with the certified value for the α-HBCD present in the sample. Finally, the method was applied to the analysis of 293 fish samples collected in water bodies from all over Slovakia, in which the highest concentrations were determined for α-HBCD with the maximum value of 31 ng g−1 ww.


Sign in / Sign up

Export Citation Format

Share Document