COMPARISON OF HEPARIN DOSE RESPONSE TO ACTIVATED CLOTTING TIME IN INFANTS AND CHILDREN FOR CARDIAC SURGERY

1998 ◽  
Vol 86 (Supplement) ◽  
pp. 73SCA
Author(s):  
EB Mossad ◽  
K Marchant ◽  
PM Bokesch ◽  
JJ Niezgoda ◽  
RBB Mee ◽  
...  
Perfusion ◽  
2020 ◽  
pp. 026765912095297
Author(s):  
Min-Ho Lee ◽  
William Riley

Background: A critical aspect of cardiopulmonary bypass (CPB) is to achieve full anticoagulation to prevent thrombosis and consumptive coagulation without using excessive amount of heparin. This can be achieved with heparin dose response (HDR) test in vitro to calculate an individualized heparin bolus to reach a target activated clotting time (ACT) and heparin concentration. However, we often observe that the measured ACT (mACT) with the calculated heparin bolus gives significant errors, both positive (mACT is higher than expected) and negative (mACT is lower), from expected ACT (eACT). Methods: We performed a retrospective study of 250 patients who underwent cardiac surgery to attain an error distribution of the mACT from eACT with calculated heparin bolus. In addition, it is aimed to identify possible patterns of baseline ACT (bACT), calculated heparin concentration (CHC) and HDR slope that are associated with the significant positive and negative errors. Results: We found that individualized heparin bolus by HDR test is consistently underestimated while it gave a significant number of positive and negative errors. Further analysis indicates that significant negative errors correlate with high bACT and slope and low CHC while significant positive errors with low bACT and slope and high CHC. Conclusion: The mACT can be substantially different from eACT. The accuracy of the HDR test appears to be dependent upon bACT, slope, and CHC. Based on our analysis, we provide several recommendations and a flow chart to improve the quality of individualized heparin management on CPB.


2016 ◽  
Vol 30 (6) ◽  
pp. 923-928 ◽  
Author(s):  
Junko Ichikawa ◽  
Satoshi Hagihira ◽  
Testu Mori ◽  
Mitsuharu Kodaka ◽  
Keiko Nishiyama ◽  
...  

Perfusion ◽  
1996 ◽  
Vol 11 (2) ◽  
pp. 125-130 ◽  
Author(s):  
Ian J Reece ◽  
Gerrard Linley ◽  
Habib Al Tareif ◽  
Rollie DeVroege ◽  
Jitesh Tolia ◽  
...  

Perfusion ◽  
2017 ◽  
Vol 32 (6) ◽  
pp. 474-480 ◽  
Author(s):  
Junko Ichikawa ◽  
Tetsu Mori ◽  
Mitsuharu Kodaka ◽  
Keiko Nishiyama ◽  
Makoto Ozaki ◽  
...  

Introduction: The substantial interpatient variability in heparin requirement has led to the use of a heparin dose response (HDR) technique. The accuracy of Hepcon-based heparin administration in achieving a target activated clotting time (ACT) using an HDR slope remains controversial. Methods: We prospectively studied 86 adult patients scheduled for cardiac surgery requiring cardiopulmonary bypass. The total dose of calculated heparin required for patient and pump priming was administered simultaneously to achieve a target ACT of 450 s for HDR on the Hepcon HMS system. Blood samples were obtained after the induction of anesthesia, at 3 min after heparin administration and after the initiation of CPB to measure kaolin ACT, HDR slope, whole-blood heparin concentration based on the HDR slope and anti-Xa heparin concentration, antithrombin and complete blood count. Results: The target ACT of 450 s was not achieved in 68.6% of patients. Compared with patients who achieved the target ACT, those who failed to achieve their target ACT had a significantly higher platelet count at baseline. Correlation between the HDR slope and heparin sensitivity was poor. Projected heparin concentration and anti-Xa heparin concentration are not interchangeable based on the Bland–Altman analysis. Conclusion: It can be hypothesized that the wide discrepancy in HDR slope versus heparin sensitivity may be explained by an inaccurate prediction of the plasma heparin level and/or the change in HDR of individual patients, depending on in vivo factors such as extravascular sequestration of heparin, decreased intrinsic antithrombin activity level and platelet count and/or activity.


2019 ◽  
Author(s):  
Daniel Dirkmann ◽  
Elisabeth Nagy ◽  
Martin Walter Britten ◽  
Juergen Peters

Abstract Background: Since inadequate heparin anticoagulation and insufficient reversal can result in complications during cardiopulmonary bypass (CPB) surgery, heparin anticoagulation monitoring by point-of-care (POC) activated clotting time (ACT) measurements is essential for CPB initiation, maintainance, and anticoagulant reversal. However, concerns exist regarding reproducibility of ACT assays and comparability of devices. Methods: We evaluated the agreement of ACT assays using four parallel measurements performed on two commonly used devices each (i.e., two Hemochron Signature Elite (Hemochron) and two Abbott i-STAT (i-STAT) devices, respectively). Blood samples from 30 patients undergoing cardiac surgery on CPB were assayed at specified steps (baseline, after heparin administration, after protamine administration) with four parallel measurements (two of each device type) using commercial Kaolin activated assays provided by the respective manufactures. Measurements were compared between identical and different device types using linear regression, Bland-Altman analyses, and calculation of Cohen’s kappa coefficient. Results: Parallel i-STAT ACTs demonstrated a good linear correlation (r=0.985). Bias, as determined by Bland-Altman analysis, was low (-3.8s; 95% limits of agreement (LOA): -77.8 -70.2s), and Cohen’s Kappa demonstrated good agreement (kappa=0.809). Hemochron derived ACTs demonstrated worse linear correlation (r=0.782), larger bias with considerably broader LOA (-13.14s; 95%LOA:-316.3-290s), and lesser concordance between parallel assays (kappa=0.554). Although demonstrating a fair linear correlation (r=0.815), parallel measurements on different ACT-devices showed large bias (-20s; 95% LOA: -290-250s) and little concordance (kappa=0.368). Overall, disconcordant results according to clinically predefined target values were more frequent with the Hemochron than i-STAT. Furthermore, while discrepancies in ACT between two parallel iSTAT assays showed little or no clinical relevance, deviations from parallel Hemochron assays and iSTAT versus Hemochron measurements revealed marked and sometimes clinically critical deviations. Conclusion: Currently used ACT point-of-care devices cannot be used interchangeably. Furthermore, our data question the reliability of the Hemochron in assessing adequacy of heparin anticoagulation monitoring for CPB.


1989 ◽  
Vol 71 (Supplement) ◽  
pp. A778
Author(s):  
J. B. Sarner ◽  
B. W. Brandom ◽  
M. L. Dong ◽  
D. Pickle ◽  
M. Weinberger ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document