Cerebral Oxygenation during Cardiopulmonary Bypass Using Near-Infrared Spectroscopy

1994 ◽  
Vol 81 (SUPPLEMENT) ◽  
pp. A63
Author(s):  
DNF. Harris ◽  
PLC. Smith ◽  
KM. Taylor
2021 ◽  
pp. 021849232110459
Author(s):  
Samira Moosaeifar ◽  
Mostafa Mousavizadeh ◽  
Tahereh Najafi Ghezeljeh ◽  
Afshin Hosseinian ◽  
Touraj Babaee ◽  
...  

Background The present study aims to compare regional oxygen supply determined by Near-Infrared Spectroscopy in the course of pulsatile perfusion with non-pulsatile perfusion during cardiopulmonary bypass in patients undergoing valvular heart surgery. Methods In this prospective randomized single-blinded trial, we enrolled adult subjects aged 18–65 years scheduled for elective valvular heart repair/replacement surgery with non-stenotic carotid arteries, employing a consecutive sampling method. Eligible patients were then randomly assigned in a 1:1 ratio to pulsatile or non-pulsatile perfusion during aortic cross-clamp. The primary outcome was regional cerebral oxygenation monitored by Near-Infrared Spectroscopy in each group. Results Seventy patients were randomly assigned, and each group comprised 35 patients. Mean age was 46.8 and 46.5 years in pulsatile and non-pulsatile groups, respectively. There were no significant between-group differences in regional cerebral oxygen saturation at different time points of cardiopulmonary bypass ( p-value for analysis of variance repeated measures: 0.923 and 0.223 for left and right hemispheres, respectively). Moreover, no significant differences in regional cerebral oxygen saturation levels from baseline between pulsatile and non-pulsatile groups at all desired time points for the left ( p = 0.51) and right ( p = 0.22) hemispheres of the brain were detected. Conclusion Pulsatile perfusion during cardiopulmonary bypass does not offer superior regional cerebral oxygenation measured by Near-Infrared Spectroscopy than non-pulsatile perfusion during cardiopulmonary bypass. Nonetheless, the efficacy of pulsatile flow in the subgroup of patients in whom cerebral blood flow is impaired due to carotid artery stenosis needs to be explored and evaluated by this method in future studies.


1999 ◽  
Vol 88 (3) ◽  
pp. 554-558 ◽  
Author(s):  
A. Timothy Lovell ◽  
Huw Owen-Reece ◽  
Clare E. Elwell ◽  
Martin Smith ◽  
John C. Goldstone

2006 ◽  
Vol 59 (3) ◽  
pp. 462-465 ◽  
Author(s):  
Nicole Nagdyman ◽  
Thilo Fleck ◽  
Birgit Bitterling ◽  
Peter Ewert ◽  
Hashim Abdul-Khaliq ◽  
...  

Neonatology ◽  
2021 ◽  
pp. 1-6
Author(s):  
Bi Ze ◽  
Lili Liu ◽  
Ge Sang Yang Jin ◽  
Minna Shan ◽  
Yuehang Geng ◽  
...  

<b><i>Background:</i></b> Accurate detection of cerebral oxygen saturation (rSO<sub>2</sub>) may be useful for neonatal brain injury prevention, and the normal range of rSO<sub>2</sub> of neonates at high altitude remained unclear. <b><i>Objective:</i></b> To compare cerebral rSO<sub>2</sub> and cerebral fractional tissue oxygen extraction (cFTOE) at high-altitude and low-altitude areas in healthy neonates and neonates with underlying diseases. <b><i>Methods:</i></b> 515 neonates from low-altitude areas and 151 from Tibet were enrolled. These neonates were assigned into the normal group, hypoxic-ischemic encephalopathy (HIE) group, and other diseases group. Near-infrared spectroscopy was used to measure rSO<sub>2</sub> in neonates within 24 h after admission. The differences of rSO<sub>2</sub>, pulse oxygen saturation (SpO<sub>2</sub>), and cFTOE levels were compared between neonates from low- and high-altitude areas. <b><i>Results:</i></b> (1) The mean rSO<sub>2</sub> and cFTOE levels in normal neonates from Tibet were 55.0 ± 6.4% and 32.6 ± 8.5%, significantly lower than those from low-altitude areas (<i>p</i> &#x3c; 0.05). (2) At high altitude, neonates with HIE, pneumonia (<i>p</i> &#x3c; 0.05), anemia, and congenital heart disease (<i>p</i> &#x3c; 0.05) have higher cFTOE than healthy neonates. (3) Compared with HIE neonates from plain areas, neonates with HIE at higher altitude had lower cFTOE (<i>p</i> &#x3c; 0.05), while neonates with heart disease in plateau areas had higher cFTOE than those in plain areas (<i>p</i> &#x3c; 0.05). <b><i>Conclusions:</i></b> The rSO<sub>2</sub> and cFTOE levels in normal neonates from high-altitude areas are lower than neonates from the low-altitude areas. Lower cFTOE is possibly because of an increase in blood flow to the brain, and this may be adversely affected by disease states which may increase the risk of brain injury.


1998 ◽  
Vol 46 (7) ◽  
pp. 603-609 ◽  
Author(s):  
Toshihiro Ohata ◽  
Yoshiki Sawa ◽  
Shigeaki Ohtake ◽  
Motonobu Nishimura ◽  
Nobuaki Hirata ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document