In vitro factor XI activation mechanism according to an optimized model of activated partial thromboplastin time test

2001 ◽  
Vol 12 (4) ◽  
pp. 289-299 ◽  
Author(s):  
A. Kramoroff ◽  
J. -M. Nigretto
1990 ◽  
Vol 63 (01) ◽  
pp. 016-023 ◽  
Author(s):  
A M H P van den Bessekaar ◽  
J Meeuwisse-Braun ◽  
R M Bertina

SummaryFive different APTT reagents, two amidolytic anti-ITa assays, one amidoiytic anti-Xa assay, and one coagulometric anti-Xa/ anti-IIa assay were used to assess the effect of heparin in patients treated for venous thromboembolic disease. Good correlations were observed between lug-transformed APYE> determined with the various reagents (correlation coefficients: 0.92-0.96).Nevertheless there were important differences in the slopes of the lines of relationship between the APTT reagents.Good correlations were observed between the anti-Xa and anti-IIa assay results (correlation coefficients: 0.92-0.97). However, the amidolytic anti-Xa activity was significantly higher (p <0.001) than the two amidolytic anti-IIa activities. Less good correlations were observed between the log-transformed APTTs and the anti-Xa or anti-IIa activities (correlation coefficients: 0.64-0.78). The correlations were improved by transforming the APTT into APTT-ratio, i.e. the ratio of the patient’s APTT to the same patient’s APTT after removal of heparin from the plasma sample by means of ECTEOLA-cellulose treatment. The correlation coefficients of log (AFTT-ratio) with anti-Xa or anti-IIa ranged from 0.76 to 0.87.For both APTT and amidolytic heparin assay, the response to in vitro heparin was different from the response to ex vivo heparin.Therefore, equivalent therapeutic ranges should be assessed by using ex vivo samples rather than in vitro heparin. Because of the response differences between the APTT reagents, it is not adequate to define a therapeutic range for heparin therapy without specification of the reagent.


1994 ◽  
Vol 72 (05) ◽  
pp. 685-692 ◽  
Author(s):  
Michael T Nurmohamed ◽  
René J Berckmans ◽  
Willy M Morriën-Salomons ◽  
Fenny Berends ◽  
Daan W Hommes ◽  
...  

SummaryBackground. Recombinant hirudin (RH) is a new anticoagulant for prophylaxis and treatment of venous and arterial thrombosis. To which extent the activated partial thromboplastin time (APTT) is suitable for monitoring of RH has not been properly evaluated. Recently, a capillary whole blood device was developed for bed-side monitoring of the APTT and it was demonstrated that this device was suitable to monitor heparin therapy. However, monitoring of RH was not evaluated.Study Objectives. To evaluate in vitro and ex vivo the responsiveness and reproducibility for hirudin monitoring of the whole blood monitor and of plasma APTT assays, which were performed with several reagents and two conventional coagulometers.Results. Large interindividual differences in hirudin responsiveness were noted in both the in vitro and the ex vivo experiments. The relationship between the APTT, expressed as clotting time or ratio of initial and prolonged APTT, and the hirudin concentration was nonlinear. A 1.5-fold increase of the clotting times was obtained at 150-200 ng/ml plasma. However, only a 2-fold increase was obtained at hirudin levels varying from 300 ng to more than 750 ng RH/ml plasma regardless of the assays. The relationship linearized upon logarithmic conversion of the ratio and the hirudin concentration. Disregarding the interindividual differences, and presuming full linearity of the relationship, all combinations were equally responsive to hirudin.Conclusions. All assays were equally responsive to hirudin. Levels up to 300 ng/ml plasma can be reliably estimated with each assay. The manual device may be preferable in situations where rapid availability of test results is necessary.


1979 ◽  
Vol 42 (05) ◽  
pp. 1355-1367 ◽  
Author(s):  
C V Prowse ◽  
A Chirnside ◽  
R A Elton

SummaryVarious factor IX concentrates have been examined in a number of in vitro tests of thrombogenicity. The results suggest that some tests are superfluous as in concentrates with activity in any of these tests activation is revealed by a combination of the non-activated partial thromboplastin time, the thrombin (or Xa) generation time and factor VIII inhibitor bypassing activity tests. Assay of individual coagulant enzymes revealed that most concentrates contained more factor IXa than Xa. However only a small number of concentrates, chiefly those that had been purposefully activated, contained appreciable amounts of either enzyme.


1998 ◽  
Vol 79 (3) ◽  
pp. 227-231
Author(s):  
L. N. Tarasova ◽  
E. Yu. Savinykh ◽  
G. K. Platonov ◽  
L. L.N. Tonin ◽  
O. I. Rechkin

The data on standardization of the activated partial thromboplastin time test all over the world and in Russia are given. The method is used as a screening one and it is of importance for revealing disorders in the first coagulation phase (hemophilia diagnosis) and heparinotherapy control. Two lyophilized forms of partial thromboplastin made of cadaverine raw materials are developed. Their specificity in revealing hemophilia, therapy control by heparin fit for a year is confirmed. The diagnosticum of one of them is a basis of the kit for determining the activated partial thromboplastin time. The possibility of its use not only in performing the test by test tube methods but as well by semiautomatic and automatic machines.


2020 ◽  
Vol 42 (3) ◽  
Author(s):  
Erica Scalambrino ◽  
Lidia Padovan ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Andrea Artoni ◽  
...  

2002 ◽  
Vol 13 (8) ◽  
pp. 725-731 ◽  
Author(s):  
J P Tsikouris ◽  
K C Jackson ◽  
D S Fike ◽  
C D Cox ◽  
G E Meyerrose ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document