Comparison of Dynamic Contrast-Enhanced Gradient-Echo and Spin-Echo Sequences in MR of Head and Neck Neoplasms

1999 ◽  
Vol 19 (2) ◽  
pp. 113
Author(s):  
E J Escott ◽  
V M Rao ◽  
W D Ko ◽  
J E Guitierrez
Head & Neck ◽  
2021 ◽  
Author(s):  
Soumya Ranjan Malla ◽  
Ashu Seith Bhalla ◽  
Smita Manchanda ◽  
Devasenathipathy Kandasamy ◽  
Rakesh Kumar ◽  
...  

2003 ◽  
Vol 48 (3) ◽  
pp. 230-236 ◽  
Author(s):  
Tabassum Laz Haque ◽  
Yukio Miki ◽  
Mitsunori Kanagaki ◽  
Takahiro Takahashi ◽  
Akira Yamamoto ◽  
...  

2021 ◽  
Vol 10 (9) ◽  
pp. 1850
Author(s):  
Seun-Ah Lee ◽  
Sang-Won Jo ◽  
Suk-Ki Chang ◽  
Ki-Han Kwon

This study aims to investigate the diagnostic ability of the contrast-enhanced 3D T1 black-blood fast spin-echo (T1 BB-FSE) sequence compared with the contrast-enhanced 3D T1-spoiled gradient-echo (CE-GRE) sequence in patients with facial neuritis. Forty-five patients with facial neuritis who underwent temporal bone MR imaging, including T1 BB-FSE and CE-GRE imaging, were examined. Two reviewers independently assessed the T1 BB-FSE and CE-GRE images in terms of diagnostic performance, and qualitative (diagnostic confidence and visual asymmetric enhancement) and quantitative analysis (contrast-enhancing lesion extent of the canalicular segment of the affected facial nerve (LEC) and the affected side-to-normal signal intensity ratio (rSI)). The AUCs of each reviewer, and the sensitivity and accuracy of T1 BB-FSE were significantly superior to those of CE-GRE (p < 0.05). Regarding diagnostic confidence and visual asymmetric enhancement, T1 BB-FSE tended to be rated greater than CE-GRE (p < 0.05). Additionally, in quantitative analysis, LEC and rSI of the canalicular segment on T1 BB-FSE were larger than those on CE-GRE (p < 0.05). The T1 BB-FSE sequence was significantly superior to the CE-GRE sequence, with more conspicuous lesion visualization in terms of both qualitative and quantitative aspects in patients with facial neuritis.


Author(s):  
Elisabeth Sartoretti ◽  
Sabine Sartoretti-Schefer ◽  
Luuk van Smoorenburg ◽  
Barbara Eichenberger ◽  
Árpád Schwenk ◽  
...  

Objectives: To compare a novel 3D spiral gradient echo (GRE) sequence with a conventional 2D cartesian turbo spin echo (TSE) sequence for sagittal contrast-enhanced (CE) fat-suppressed (FS) T1 weighted (T1W) spine MRI. Methods: In this inter-individual comparison study, 128 patients prospectively underwent sagittal CE FS T1W spine MRI with either a 2D cartesian TSE (“TSE”, 285 s, 64 patients) or a 3D spiral GRE sequence (“Spiral”, 93 s, 64 patients). Between both groups, patients were matched in terms of anatomical region (cervical/thoracic/lumbar spine and sacrum). Three readers used 4-point Likert scales to assess images qualitatively in terms of overall image quality, presence of artifacts, spinal cord visualization, lesion conspicuity and quality of fat suppression. Results: Spiral achieved a 67.4% scan time reduction compared to TSE. Interreader agreement was high (alpha=0.868-1). Overall image quality (4;[3,4] vs 3;[3,4], p<0.001 – p=0.002 for all readers), presence of artifacts (4;[3,4] vs 3;[3,4] p=0.027 – p=0.046 for all readers), spinal cord visualization (4;[4,4] vs 4;[3,4], p<0.001 for all readers), lesion conspicuity (4;[4,4] vs 4;[4,4], p=0.016 for all readers) and quality of fat suppression (4;[4,4] vs 4;[4,4], p=0.027 – p=0.033 for all readers), were all deemed significantly improved by all three readers on Spiral images as compared to TSE images Conclusion: We demonstrate the feasibility of a novel 3D spiral GRE sequence for improved and rapid sagittal CE FS T1W spine MRI. Advances in knowledge: A 3D spiral GRE sequence allows for improved sagittal CE FS T1W spine MRI at very short scan times.


2005 ◽  
Vol 184 (1) ◽  
pp. 313-319 ◽  
Author(s):  
Masako Kataoka ◽  
Hiroyuki Ueda ◽  
Takashi Koyama ◽  
Shigeaki Umeoka ◽  
Kaori Togashi ◽  
...  

Sign in / Sign up