Intraobserver and Interobserver Agreement in Evaluating the Anterior Chamber Angle Configuration by Ultrasound Biomicroscopy

1997 ◽  
Vol 6 (1) ◽  
pp. 13???17 ◽  
Author(s):  
George L. Spaeth ◽  
Augusto Azuara-Blanco ◽  
Silvana V. Araujo ◽  
James J. Augsburger
2014 ◽  
Vol 23 (2) ◽  
pp. 61-68 ◽  
Author(s):  
Zhong Lin ◽  
Da P. Mou ◽  
Yuan B. Liang ◽  
Si Z. Li ◽  
Rui Zhang ◽  
...  

2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Nicholas P. Bell ◽  
Kundandeep S. Nagi ◽  
Ricardo J. Cumba ◽  
Alice Z. Chuang ◽  
David A. Lee ◽  
...  

Purpose. To investigate age- and position-related changes of anterior chamber angle anatomy in normal, healthy eyes. Patients and Methods. Thirty subjects were separated into a younger and older cohort. The superior and inferior anterior chamber angles of the eyes were measured in supine and sitting positions by ultrasound biomicroscopy (UBM) with bag/balloon technology. Statistical analysis was used to evaluate positional and age-related changes in angle morphology. Results. In the younger cohort, no location or positional differences in angle anatomy were observed. In the older cohort, the inferior quadrant was significantly narrower than the superior quadrant (P=0.0186) in the supine position. This cohort also demonstrated an interaction effect between position and location. In the older cohort, the angle was deeper inferiorly while the subject was sitting but was deeper superiorly while the subject was supine. Conclusion. Comparison of positional variations in anterior chamber angle anatomy as measured by UBM has recently become possible. This study found that age-related positional changes in the anterior chamber angle anatomy exist in normal healthy eyes.


2013 ◽  
Vol 94 (6) ◽  
pp. 853-858
Author(s):  
A A Ryabtseva ◽  
M P Yugaj ◽  
N S Nikitina

Aim. To study the changes of anatomic and topographic characteristics of the eye anterior segment after uncomplicated cataract phacoemulsification using corneal incision with intraocular soft lens implantation. Methods. The data of ultrasound biomicroscopy and noncontact tonometry of 58 eyes (56 patients, 32 females, 24 males aged 54 to 78 years) before and after cataract phacoemulsification were analyzed. Paitents with survived ocular trauma, refractive keratoplasty, glaucoma, uveitis, and surgical complications (incomplete capsulorrhexis, posterior capsule rupture, ciliary zonule disinsertion, corneal burn). Apart from the common examinations (visual acuity testing, tonometry, tonography, eye A- and B-ultrasonography, biomicroscopy), all patients underwent eye ultrasound biomicroscopy. Results. Anterior chamber depth increased from 2.73±0.10 to 4.17±0.06 mm (p ≤0.001). Trabecula-iris distance measured at 500 μm from the scleral spur, increased from 0.38±0.02 to 0.47±0.02 mm (p ≤0.001). Anterior chamber angle increased from 28.69±1.87 to 42.73±1.56 degrees (p ≤0.001), the angle between the iris and the sclera increased from 32.78±1.39 to 41.36±0.84 degrees (p ≤0.001), the angle between the sclera and ciliary processes increased from 39.48±1.29 to 45.30±1.16 degrees (p ≤0.001). Intraocular pressure according to the non-contact tonometry data decreased from 18.16±1.29 to 13.55±0.95 mm Hg (p ≤0.001). Conclusion. Anterior chamber depth, trabecula-iris distance, anterior chamber angle, the angle between sclera and iris and the angle between sclera and ciliary processes increased significantly after phacoemulsification with intraocular lens implantation. Intraocular pressure decreased significantly according to the non-contact tonometry data.


2019 ◽  
pp. 1
Author(s):  
Wanyue Li ◽  
Qian Chen ◽  
Zhenying Jiang ◽  
Guohua Deng ◽  
Yuan Zong ◽  
...  

2004 ◽  
Vol 30 (5) ◽  
pp. 1098-1101 ◽  
Author(s):  
Josef Stoiber ◽  
Johann Ebner ◽  
Wolfgang Hitzl ◽  
Josef Ruckhofer ◽  
Günther Grabner

2012 ◽  
Vol 2012 ◽  
pp. 1-14 ◽  
Author(s):  
Ricardo J. Cumba ◽  
Sunita Radhakrishnan ◽  
Nicholas P. Bell ◽  
Kundandeep S. Nagi ◽  
Alice Z. Chuang ◽  
...  

Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL) and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT) images.Methods. Two independent, masked observers (SR and AZC) identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750), and angle opening distance (AOD750) were calculated.Results. In 84% of quadrants, SR’s SSL placements during 2 sessions were within 80 μm in both theX- andY-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication) were above 0.9 for TISA750 and AOD750 for all quadrants.Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750.


2010 ◽  
Vol 40 (4) ◽  
pp. 194-198
Author(s):  
İlhami Salcan ◽  
Ümit Aykan ◽  
Kadir Çolakoğlu ◽  
Ali Aydın ◽  
Dilaver Erşanlı

Sign in / Sign up

Export Citation Format

Share Document