Arterial to End-Tidal Carbon Dioxide Pressure Difference During Laparoscopic Surgery in Pregnancy

2001 ◽  
Vol 45 (3) ◽  
pp. 159-160
2000 ◽  
Vol 93 (2) ◽  
pp. 370-373 ◽  
Author(s):  
Kodali Bhavani-Shankar ◽  
Richard A. Steinbrook ◽  
David C. Brooks ◽  
Sanjay Datta

Background There is controversy about whether capnography is adequate to monitor pulmonary ventilation to reduce the risk of significant respiratory acidosis in pregnant patients undergoing laparoscopic surgery. In this prospective study, changes in arterial to end-tidal carbon dioxide pressure difference (PaCO2--PetCO2), induced by carbon dioxide pneumoperitoneum, were determined in pregnant patients undergoing laparoscopic cholecystectomy. Methods Eight pregnant women underwent general anesthesia at 17-30 weeks of gestation. Carbon dioxide pnueumoperitoneum was initiated after obtaining arterial blood for gas analysis. Pulmonary ventilation was adjusted to maintain PetCO2 around 32 mmHg during the procedure. Arterial blood gas analysis was performed during insufflation, after the termination of insufflation, after extubation, and in the postoperative period. Results The mean +/- SD for PaCO2--PetCO2 was 2.4 +/- 1.5 before carbon dioxide pneumoperitoneum, 2.6 +/- 1.2 during, and 1.9 +/- 1.4 mmHg after termination of pneumoperitoneum. PaCO2 and pH during pneumoperitoneum were 35 +/- 1.7 mmHg and 7.41 +/- 0.02, respectively. There were no significant differences in either mean PaCO2--PetCO2 or PaCO2 and pH during various phases of laparoscopy. Conclusions Capnography is adequate to guide ventilation during laparoscopic surgery in pregnant patients. Respiratory acidosis did not occur when PetCO2 was maintained at 32 mmHg during carbon dioxide pneumoperitoneum.


2021 ◽  
Vol 28 (Supplement_1) ◽  
Author(s):  
J Ferreira ◽  
P Rio ◽  
A Castelo ◽  
I Cardoso ◽  
S Silva ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background Although several cardiopulmonary exercise testing (CPET) parameters have already proved to predict prognosis, there is increasing interest in finding variables that do not require maximal effort. End-tidal carbon dioxide pressure (PETCO2), an indirect indicator of cardiac output, is one of such variables. Studies in heart failure populations already suggest its role as a prognostic factor. However, data concerning other populations are still scarce. Purpose To assess the association between exercise PETCO2, cardiac biomarkers and systolic function following acute myocardial infarction (AMI) and to evaluate its potential prognostic role in this population. Methods A retrospective single-centre analysis was conducted including patients who underwent symptom-limited CPET early after AMI. We assessed PETCO2 at baseline (PETCO2-B), at anaerobic threshold (PETCO2-AT) and at peak exercise and calculated the difference between PETCO2-AT and PETCO2-B (PETCO2-difference). We analysed their association with B-natriuretic peptide (BNP), maximal troponin after AMI as well as with left ventricular ejection fraction (LVEF) 1 year after. Results We included 40 patients with a mean age of 56 years (87.5% male), assessed with CPET a median of 3 months after AMI (80% of which were ST-elevation myocardial infarctions). Average respiratory exchange ratio was 1,1 with 48% of patients not reaching maximal effort. Mean PETCO2-AT was 37mmHg, with a mean increase from baseline of 6mmHg (PETCO2-difference). There was a significant positive correlation between all the PETCO2 variables measured and BNP values at time of AMI and on follow-up (best correlation for PETCO2-AT with BNP at AMI hospitalization, r = 0.608, p < 0.001). Maximal troponin was not correlated with PETCO2. Both PETCO2-AT and PETCO2-difference were significantly and positively correlated with LVEF 1-year post-AMI (r = 0.421, p = 0.040 and r = 0.511, p = 0.011, respectively). Conclusion PETCO2-AT and PETCO2-difference are both correlated with BNP, an established prognostic marker, and with medium-term systolic function after AMI, suggesting their potential prognostic role in this population. Further studies with larger samples are required to confirm the results of this pilot study and assess PETCO2 as a definite predictor of prognosis after AMI.


2009 ◽  
Vol 111 (3) ◽  
pp. 609-615 ◽  
Author(s):  
Yusuke Kasuya ◽  
Ozan Akça ◽  
Daniel I. Sessler ◽  
Makoto Ozaki ◽  
Ryu Komatsu

Background Obtaining accurate end-tidal carbon dioxide pressure measurements via nasal cannula poses difficulties in postanesthesia patients who are mouth breathers, including those who are obese and those with obstructive sleep apnea (OSA); a nasal cannula with an oral guide may improve measurement accuracy in these patients. The authors evaluated the accuracy of a mainstream capnometer with an oral guide nasal cannula and a sidestream capnometer with a nasal cannula that did or did not incorporate an oral guide in spontaneously breathing non-obese patients and obese patients with and without OSA during recovery from general anesthesia. Methods The study enrolled 20 non-obese patients (body mass index less than 30 kg/m) without OSA, 20 obese patients (body mass index greater than 35 kg/m) without OSA, and 20 obese patients with OSA. End-tidal carbon dioxide pressure was measured by using three capnometer/cannula combinations (oxygen at 4 l/min): (1) a mainstream capnometer with oral guide nasal cannula, (2) a sidestream capnometer with a nasal cannula that included an oral guide, and (3) a sidestream capnometer with a standard nasal cannula. Arterial carbon dioxide partial pressure was determined simultaneously. The major outcome was the arterial-to-end-tidal partial pressure difference with each combination. Results In non-obese patients, arterial-to-end-tidal pressure difference was 3.0 +/- 2.6 (mean +/- SD) mmHg with the mainstream capnometer, 4.9 +/- 2.3 mmHg with the sidestream capnometer and oral guide cannula, and 7.1 +/- 3.5 mmHg with the sidestream capnometer and a standard cannula (P < 0.05). In obese non-OSA patients, it was 3.9 +/- 2.6 mmHg, 6.4 +/- 3.1 mmHg, and 8.1 +/- 5.0 mmHg, respectively (P < 0.05). In obese OSA patients, it was 4.0 +/- 3.1 mmHg, 6.3 +/- 3.2 mmHg, and 8.3 +/- 4.6 mmHg, respectively (P < 0.05). Conclusions Mainstream capnometry performed best, and an oral guide improved the performance of sidestream capnometry. Accuracy in non-obese and obese patients, with and without OSA, was similar.


Sign in / Sign up

Export Citation Format

Share Document