Distance and Near Visual Acuity in Infantile Nystagmus

2006 ◽  
Vol 83 (11) ◽  
pp. 823-829 ◽  
Author(s):  
KARA S. HANSON ◽  
HAROLD E. BEDELL ◽  
JANIS M. WHITE ◽  
MICHAEL T. UKWADE
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yueyang Zhong ◽  
Kai Wang ◽  
Xiaoning Yu ◽  
Xin Liu ◽  
Ke Yao

AbstractThis meta-analysis aimed to evaluate the clinical outcomes following implantation of trifocal intraocular lenses (IOLs) or a hybrid multifocal-extended depth of focus (EDOF) IOL in cataract or refractive lens exchange surgeries. We examined 13 comparative studies with bilateral implantation of trifocal (898 eyes) or hybrid multifocal-EDOF (624 eyes) IOLs published through 1 March 2020. Better uncorrected and corrected near visual acuity (VA) were observed in the trifocal group (MD: − 0.143, 95% CI: − 0.192 to − 0.010, P < 0.001 and MD: − 0.149, 95% CI: − 0.217 to − 0.082, P < 0.001, respectively), while the hybrid multifocal-EDOF group presented better uncorrected intermediate VA (MD: 0.055, 95% CI: 0.016 to 0.093, P = 0.005). Trifocal IOLs were more likely to achieve spectacle independence at near distance (RR: 1.103, 95% CI: 1.036 to 1.152, P = 0.002). The halo photic effect was generated more frequently by the trifocal IOLs (RR: 1.318, 95% CI: 1.025 to 1.696, P = 0.031). Contrast sensitivity and subjective visual quality yielded comparable results between groups. Trifocal IOLs demonstrated better performance at near distance but apparently led to more photic disturbances. Our findings provided the most up-to-date and comprehensive evidence by comparing the benefits of advanced IOLs in clinical practice.


Author(s):  
Jan Kremláček ◽  
Jana Nekolová ◽  
Markéta Středová ◽  
Jana Langrová ◽  
Jana Szanyi ◽  
...  

Abstract Background For patients with age-related macular degeneration (AMD), a special intraocular lens implantation partially compensates for the loss in the central part of the visual field. For six months, we evaluated changes in neurophysiological parameters in patients implanted with a “Scharioth macula lens” (SML; a center near high add + 10 D and peripheral plano carrier bifocal lens designed to be located between the iris and an artificial lens). Methods Fourteen patients (5 M, 9 F, 63–87 years) with dry AMD were examined prior to and at 3 days after, as well as 1, 2, and 6 months after, implantation using pattern-reversal, motion-onset, and cognitive evoked potentials, psychophysical tests evaluating distant and near visual acuity, and contrast sensitivity. Results Near visual acuity without an external aid was significantly better six months after implantation than before implantation (Jaeger table median (lower; upper quartile): 4 (1; 6) vs. 15 (13; 17)). Distant visual acuity was significantly altered between the pre- (0.7 (0.5; 0.8) logMAR) and last postimplantation visits (0.8 (0.7; 0.8) logMAR), which matched prolongation of the P100 peak time (147 (135; 151) ms vs. 161 (141; 166) ms) of 15 arc min pattern-reversal VEPs and N2 peak time (191.5 (186.5; 214.5) ms vs. 205 (187; 218) ms) of peripheral motion-onset VEPs. Conclusion SML implantation significantly improved near vision. We also observed a slight but significant decrease in distant and peripheral vision. The most efficient electrophysiological approach to test patients with SML was the peripheral motion-onset stimulation, which evoked repeatable and readable VEPs.


2014 ◽  
Vol 55 (4) ◽  
pp. 2682 ◽  
Author(s):  
Matt J. Dunn ◽  
Tom H. Margrain ◽  
J. Margaret Woodhouse ◽  
Fergal A. Ennis ◽  
Christopher M. Harris ◽  
...  

2011 ◽  
Vol 14 (12) ◽  
pp. 2236-2244 ◽  
Author(s):  
Myriam Fillion ◽  
Mélanie Lemire ◽  
Aline Philibert ◽  
Benoît Frenette ◽  
Hope Alberta Weiler ◽  
...  

AbstractObjectiveTo examine the associations between near and distant visual acuity and biomarkers of Hg, Pb, n-3 fatty acids and Se from the local diet of fish-eating communities of the Tapajós River in the Brazilian Amazon.DesignVisuo-ocular health and biomarkers of Hg (hair, whole blood, plasma), Pb (whole blood), Se (whole blood and plasma) and n-3 fatty acids (plasma total phospholipids) were assessed in a cross-sectional study.SettingLower Tapajós River Basin (State of Pará, Brazil), May to July 2006.SubjectsTwo hundred and forty-three adults (≥15 years) without diagnosed age-related cataracts or ocular pathologies.ResultsNear visual acuity was negatively associated with hair Hg and positively associated with %DHA, with a highly significant Log Hg × age interaction term. Stratifying for age showed that while young people presented good acuity, for those aged ≥40 years, clinical presbyopia was associated with hair Hg ≥ 15 μg/g (OR = 3·93, 95 % CI 1·25, 14·18) and %DHA (OR = 0·37, 95 % CI 0·11, 1·11). A similar age-related pattern was observed for distant visual acuity in relation to blood Pb, but the evidence was weaker.ConclusionsThese findings suggest that Hg and Pb may affect visual acuity in older persons, while DHA appears to be protective for near visual acuity loss. In this population, with little access to eye care, diet may have an important influence on visuo-ocular ageing.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2018 ◽  
Vol 29 (4) ◽  
pp. 426-430 ◽  
Author(s):  
Omer Trivizki ◽  
David Smadja ◽  
Michael Mimouni ◽  
Samuel Levinger ◽  
Eliya Levinger

Purpose:To analyze the visual and refractive outcome of the bioptics procedure combining multifocal intraocular lens implantation and excimer laser surgery in young patients with high hyperopic eyes not suitable for a single surgical procedure.Methods:This retrospective case series included 10 eyes of five patients (age range 18–30 years) with high hyperopia (spherical equivalent +8.51 ± 0.85 diopters (D)). They had been treated with serial multifocal intraocular lens implantation followed 6 weeks later by laser in situ keratomileusis for residual hyperopia. Uncorrected distance visual acuity, uncorrected near visual acuity, corrected distance visual acuity, corrected near visual acuity, and manifest refraction were evaluated before surgeries, after multifocal intraocular lens implantation, and 3 months post laser in situ keratomileusis.Results:No patients were lost to follow-up (6 months). The mean spherical equivalent decreased to +2.05 ± 1.33 D after multifocal intraocular lens implantation and to −0.10 ± 0.58 D after the laser in situ keratomileusis procedure. Success of the procedures was determined by uncorrected visual acuity. LogMAR uncorrected distance visual acuity improved by a total of more than six lines from 1.05 ± 0.18 LogMAR to 0.46 ± 0.12 LogMAR post multifocal intraocular lens implantation and to 0.15 ± 0.06 LogMAR after both surgeries. The LogMAR uncorrected near visual acuity increased by 0.81 ± 0.82 LogMAR after lens implantation due to loss of accommodation, and all eyes reached a LogMAR of 0 at 1 month postoperatively following laser in situ keratomileusis.Conclusions:A bioptics approach involving multifocal intraocular lens followed 6 weeks later by a laser in situ keratomileusis procedure for the correction of very high hyperopia enabled the resolution of the residual refractive error in young very high hyperopic patients.


1995 ◽  
Vol 15 (1) ◽  
pp. 53-58 ◽  
Author(s):  
T. C. A. Jenkins ◽  
F. Abd-Manan ◽  
S. Pardhan

2017 ◽  
Vol 27 (4) ◽  
pp. 460-465 ◽  
Author(s):  
Ramón Ruiz-Mesa ◽  
Antonio Abengózar-Vela ◽  
Ana Aramburu ◽  
María Ruiz-Santos

Purpose To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal. Methods Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire. Results The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05). Conclusions Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.


Sign in / Sign up

Export Citation Format

Share Document