Differentiation Between Benign and Malignant Breast Tumors Using Kinetic Features of Real-Time Harmonic Contrast-Enhanced Ultrasound

2012 ◽  
Vol 28 (4) ◽  
pp. 306-307
Author(s):  
Yoshimi Endo
2012 ◽  
Vol 53 (4) ◽  
pp. 382-388 ◽  
Author(s):  
Ariel Saracco ◽  
Botond K Szabó ◽  
Peter Aspelin ◽  
Karin Leifland ◽  
Brigitte Wilczek ◽  
...  

2016 ◽  
Vol 58 (4) ◽  
pp. 394-402 ◽  
Author(s):  
Ariel Saracco ◽  
Botond K Szabó ◽  
Ervin Tánczos ◽  
Jonas Bergh ◽  
Thomas Hatschek

Background One of the big challenges in onco-radiology is to find a reliable imaging method that may predict early response during the first cycles of any neoadjuvant chemotherapy. Purpose To evaluate the use of real-time harmonic contrast-enhanced ultrasound (CEUS) in predicting early response in breast cancer tumors under neoadjuvant chemotherapy (NAC) treatment. Material and Methods Nineteen consecutive patients with invasive breast cancer were evaluated with a bolus dose of 2.4 mL contrast agent using CEUS, before and after two cycles of epirubicin and docetaxel. The lognormal function was used for quantitative analysis of kinetic data to evaluate early response. Results There was statistically significant difference in time-to-peak ( tp) between responders and non-responders (two sample t-test, P = 0.027) where tp was significantly longer at the week 5 than at the baseline scan among responders when compared to non-responders. Conclusion In-flow of intravascular contrast agent in tumors is significantly slower in responders at real-time harmonic CEUS, and might be effectively used for the evaluation of early response to chemotherapy in invasive breast cancer. However, further investigations in a larger and more heterogeneous population should be performed to corroborate the reliability of the method.


VASA ◽  
2019 ◽  
Vol 48 (2) ◽  
pp. 115-125 ◽  
Author(s):  
Xin Li ◽  
Daniel Staub ◽  
Vasileios Rafailidis ◽  
Mohammed Al-Natour ◽  
Sanjeeva Kalva ◽  
...  

Abstract. Ultrasound has been established as an important diagnostic tool in assessing vascular abnormalities. Standard B-mode and Doppler techniques have inherent limitations with regards to detection of slow flow and small vasculature. Contrast-enhanced ultrasound (CEUS) is a complementary tool and is useful in assessing both the macro- and microvascular anatomy of the aorta. CEUS can also provide valuable physiological information in real-time scanning sessions due to the physical and safety profiles of the administered microbubbles. From a macrovascular perspective, CEUS has been used to characterize aortic aneurysm rupture, dissection and endoleaks post-EVAR repair. With regard to microvasculature CEUS enables imaging of adventitial vasa vasorum thereby assessing aortic inflammation processes, such as monitoring treatment response in chronic periaortitis. CEUS may have additional clinical utility since adventitial vasa vasorum has important implications in the pathogenesis of aortic diseases. In recent years, there have been an increasing number of studies comparing CEUS to cross-sectional imaging for aortic applications. For endoleak surveillance CEUS has been shown to be equal or in certain cases superior in comparison to CT angiography. The recent advancement of CEUS software along with the ongoing development of drug-eluting contrast microbubbles has allowed improved targeted detection and real-time ultrasound guided therapy for aortic vasa vasorum inflammation and neovascularization in animal models. Therefore, CEUS is uniquely suited to comprehensively assess and potentially treat aortic vascular diseases in the future.


2021 ◽  
Vol 49 (5) ◽  
pp. 030006052110106
Author(s):  
Shanhong Lin ◽  
Yong Cao ◽  
Libin Chen ◽  
Mei Chen ◽  
Shengmin Zhang ◽  
...  

We herein present a rare case of breast fibromatosis, the contrast-enhanced ultrasonography (CEUS) findings of which we believe have never been described. The high similarity between the clinical and imaging manifestations of breast cancer makes its differential diagnosis difficult. In this report, we describe the CEUS findings of a less common type of fibromatosis, discuss the potential value of CEUS to differentiate it from malignant breast lesions, and briefly review the literature.


2010 ◽  
Vol 83 (989) ◽  
pp. 411-418 ◽  
Author(s):  
Z Wang ◽  
H-X Xu ◽  
X-Y Xie ◽  
X-H Xie ◽  
M Kuang ◽  
...  

2016 ◽  
Vol 41 (10) ◽  
pp. 1973-1979 ◽  
Author(s):  
Zhu Wang ◽  
Wei Wang ◽  
Guang-Jian Liu ◽  
Zheng Yang ◽  
Li-Da Chen ◽  
...  

Circulation ◽  
2001 ◽  
Vol 104 (21) ◽  
pp. 2582-2587 ◽  
Author(s):  
Se-Joong Rim ◽  
Howard Leong-Poi ◽  
Jonathan R. Lindner ◽  
Daniel Couture ◽  
Dilantha Ellegala ◽  
...  

2008 ◽  
Vol 27 (4) ◽  
pp. 657-666 ◽  
Author(s):  
Guang-Jian Liu ◽  
Ming-De Lu ◽  
Xiao-Yan Xie ◽  
Hui-Xiong Xu ◽  
Zuo-Feng Xu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document