Positive End-expiratory Pressure Influences Echocardiographic Measures of Diastolic Function

2013 ◽  
Vol 119 (5) ◽  
pp. 1078-1086 ◽  
Author(s):  
Peter Juhl-Olsen ◽  
Johan Fridolf Hermansen ◽  
Christian Alcaraz Frederiksen ◽  
Linda Aagaard Rasmussen ◽  
Carl-Johan Jakobsen ◽  
...  

Abstract Background: Ultrasonography of the cardiovascular system is pivotal for hemodynamic assessment. Diastolic function is evaluated with a combination of tissue Doppler (e’ and a’) and pulsed Doppler (E and A) measures of transmitral- and mitral valve annuli velocities. However, accurate echocardiographic evaluation in the intensive care unit or perioperative setting is contingent on relative resistance to positive pressure ventilation and changes in preload. This study aimed to evaluate the effects of positive end-expiratory pressure (PEEP) and positioning on echocardiographic measures of diastolic function. Methods: The study was a prospective, randomized, crossover study. Cardiac surgery patients with ejection fraction greater than 45% and averaged e’ of 9 or more were included. Postoperatively, anesthetized patients were randomized into six combinations of PEEP (0, 6, 12 cm H2O) and positions (horizontal, Trendelenburg). At each combination, e’ (primary endpoint), a’, E, and A were obtained with transesophageal echocardiography along with left ventricular area. Image analysis was performed blinded to the protocol. Results: Thirty patients completed the study. PEEP decreased lateral e’ from 6.6 ± 3.6 to 5.3 ± 3.0 cm/s (P < 0.001) in the horizontal position and from 7.4 ± 4.2 to 6.5 ± 3.3 cm/s (P < 0.001) in Trendelenburg. Similar results were found for septal e’, a’ bilaterally and transmitral pulsed Doppler measures, and PEEP decreased left ventricular area. E/A, E/e’, and e’/a’ remained unaffected by PEEP and positioning. Conclusions: When evaluating diastolic function by echocardiography, the levels of PEEP and its effect on ventricular area have to be taken into account. In addition, this study dissuades the use of E/e’ for tracking changes in left ventricular filling pressures in cardiac surgery patients.

Author(s):  
Patrizio Lancellotti ◽  
Bernard Cosyns

Diastole is the part of the cardiac cycle starting at aortic valve closure and ending at mitral valve closure. Evaluation of diastolic function by echocardiography is useful to diagnose heart failure with preserved ejection fraction, and regardless of ejection fraction, echocardiography can be used to estimate left ventricular filling pressure. Assessment of diastolic function includes analysis of left ventricular relaxation and compliance, left atrial and left ventricular filling pressures. This chapter describes the phases of diastole and covers the integrated approach of LV diastolic function through M-Mode and 2D/3D echocardiography, pulsed-wave Doppler echocardiography, and pulsed-wave tissue Doppler echocardiography.


Author(s):  
Ljiljana Sulovic ◽  
Vladimir Sulovic ◽  
Zorica Zivkovic ◽  
Maja Vasic ◽  
Nenad Sulovic ◽  
...  

Assessment of cardiac function is the leading parameter when evaluating the state of the cardiovascular system of patients undergoing chronic hemodialysis. The aim of the paper: to assess the state of the cardiovascular system of these patients using new sensitive echocardiography and Doppler techniques and thus advance the prevention of cardiovascular disease.Method: Twenty children with end-stage renal insufficiency on chronic hemodialysis and twenty healthy controls underwent echocardiographic monitoring using standard Doppler and tissue Doppler imaging. Structural and functional changes in the left ventricle were evaluated.Results: Patients on hemodialysis had significantly greater left ventricular mass indices compared to the controls (p<0.001). The patients on hemodialysis had preserved systolic function – their fractional shortening, ejection fraction and Sm (systolic myocardial velocity) did not differ significantly compared to the controls (p>0.05). Early diastolic function in children on hemodialysis was also preserved: the E/A and Em/Am ratio did not differ significantly from the control group (p>0.05). Children on hemodialysis exhibited impaired late diastolic function (compliance index), that is, considerably higher E/Em compared to controls (p<0.00). Myocardial Performance Index values showed statistically significant elevation in children on hemodialysis compared to the control group (p<0.001).Conclusion: Tissue Doppler in tandem with conventional Pulsed Doppler can provide additional information on left ventricular filling pressures (E/Em) in children on hemodialysis. It is therefore recommended to perform routine measuring of Em waves and the E/Em ratio, not only in order to evaluate myocardial relaxation and ventricular filling pressures, but primarily to stratify risk and provide a prognosis.


Author(s):  
Ljiljana Sulovic ◽  
Vladimir Sulovic ◽  
Zorica Zivkovic ◽  
Jovan Zivkovic ◽  
Maja Vasic ◽  
...  

Assessment of cardiac function is the leading parameter when evaluating the state of the cardiovascular system of patients undergoing chronic hemodialysis. The aim of the paper: to assess the state of the cardiovascular system of these patients using new sensitive echocardiography and Doppler techniques and thus advance the prevention of cardiovascular disease. Method: Twenty children with end-stage renal insufficiency on chronic hemodialysis and twenty healthy controls underwent echocardiographic monitoring using standard Doppler  and tissue Doppler imaging. Structural and functional changes in the left ventricle were evaluated. Results: Patients on hemodialysis had significantly greater left ventricular mass indices compared to the controls (p < 0.001). The patients on hemodialysis had preserved systolic function—their fractional shortening, ejection fraction and Sm (systolic myocardial velocity) did not differ significantly compared to the controls (p > 0.05). Early diastolic function in children on hemodialysis was also preserved: the E/A and Em/Am ratio did not differ significantly from the control group (p > 0.05). Children on hemodialysis exhibited impaired late diastolic function (compliance index), that is, considerably higher E/Em compared to controls (p < 0.00). Myocardial Performance Index values showed statistically significant elevation in children on hemodialysis compared to the control group (p < 0.001). Conclusion: Tissue Doppler in tandem with conventional Pulsed Doppler can provide additional information on left ventricular filling pressures (E/Em) in children on hemodialysis. It is therefore recommended to perform routine measuring of Em waves and the E/Em ratio, not only in order to evaluate myocardial relaxation and ventricular filling pressures, but primarily to stratify risk and provide a prognosis.


2012 ◽  
Vol 30 (3) ◽  
pp. 271-278 ◽  
Author(s):  
Kanwal Kumar ◽  
Roman G. Nepomuceno ◽  
Anjala Chelvanathan ◽  
Mehrdad Golian ◽  
Sheena Bohonis ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document