Treatment of Pediatric and Adolescent Pelvic Ring Injuries With Percutaneous Screw Placement

2018 ◽  
Vol 38 (3) ◽  
pp. 133-137 ◽  
Author(s):  
John A. Scolaro ◽  
Reza Firoozabadi ◽  
Milton L. “Chip” Routt
Injury ◽  
2015 ◽  
Vol 46 (2) ◽  
pp. 333-339 ◽  
Author(s):  
Oliver Pieske ◽  
Christoph Landersdorfer ◽  
Christoph Trumm ◽  
Axel Greiner ◽  
Jens Wallmichrath ◽  
...  

Author(s):  
Giuseppe Rovere ◽  
Andrea Perna ◽  
Luigi Meccariello ◽  
Domenico De Mauro ◽  
Alessandro Smimmo ◽  
...  

Abstract Introduction Pelvic ring injuries, frequently caused by high energy trauma, are associated with high rates of morbidity and mortality (5–33%), often due to significant blood loss and disruption of the lumbosacral plexus, genitourinary system, and gastrointestinal system. The aim of the present study is to perform a systematic literature review on male and female sexual dysfunctions related to traumatic lesions of the pelvic ring. Methods Scopus, Cochrane Library MEDLINE via PubMed, and Embase were searched using the keywords: “Pelvic fracture,” “Pelvic Ring Fracture,” “Pelvic Ring Trauma,” “Pelvic Ring injury,” “Sexual dysfunction,” “Erectile dysfunction,” “dyspareunia,” and their MeSH terms in any possible combination. The following questions were formulated according to the PICO (population (P), intervention (I), comparison (C), and outcome (O)) scheme: Do patients suffering from pelvic fracture (P) report worse clinical outcomes (C), in terms of sexual function (O), when urological injury occurs (I)? Is the sexual function (O) influenced by the type of fracture (I)? Results After screening 268 articles by title and abstract, 77 were considered eligible for the full-text analysis. Finally 17 studies that met inclusion criteria were included in the review. Overall, 1364 patients (902 males and 462 females, M/F ratio: 1.9) suffering from pelvic fractures were collected. Discussion Pelvic fractures represent challenging entities, often concomitant with systemic injuries and subsequent morbidity. Anatomical consideration, etiology, correlation between sexual dysfunction and genitourinary lesions, or pelvic fracture type were investigated. Conclusion There are evidences in the literature that the gravity and frequency of SD are related with the pelvic ring fracture type. In fact, patients with APC, VS (according Young-Burgess), or C (according Tile) fracture pattern reported higher incidence and gravity of SD. Only a week association could be found between GUI and incidence and gravity of SD, and relationship between surgical treatment and SD. Electrophysiological tests should be routinely used in patient suffering from SD after pelvic ring injuries.


Author(s):  
M. F. Hoffmann ◽  
E. Yilmaz ◽  
D. C. Norvel ◽  
T. A. Schildhauer

Abstract Purpose Instability of the posterior pelvic ring may be stabilized by lumbopelvic fixation. The optimal osseous corridor for iliac screw placement from the posterior superior iliac spine to the anterior inferior iliac spine requires multiple ap- and lateral-views with additional obturator-outlet and -inlet views. The purpose of this study was to determine if navigated iliac screw placement for lumbopelvic fixation influences surgical time, fluoroscopy time, radiation exposure, and complication rates. Methods Bilateral lumbopelvic fixation was performed in 63 patients. Implants were inserted as previously described by Schildhauer. A passive optoelectronic navigation system with surface matching on L4 was utilized for navigated iliac screw placement. To compare groups, demographics were assessed. Operative time, fluoroscopic time, and radiation were delineated. Results Conventional fluoroscopic imaging for lumbopelvic fixation was performed in 32 patients and 31 patients underwent the procedure with navigated iliac screw placement. No differences were found between the groups regarding demographics, comorbidities, or additional surgical procedures. Utilization of navigation led to fluoroscopy time reduction of more than 50% (3.2 vs. 8.6 min.; p < 0.001) resulting in reduced radiation (2004.5 vs. 5130.8 Gy*cm2; p < 0.001). Operative time was reduced in the navigation group (176.7 vs. 227.4 min; p = 0.002) despite the necessity of additional surface referencing. Conclusion For iliac screws, identifying the correct entry point and angle of implantation requires detailed anatomic knowledge and multiple radiographic views. In our study, additional navigation reduced operative time and fluoroscopy time resulting in a significant reduction of radiation exposure for patients and OR personnel.


Injury ◽  
2021 ◽  
Author(s):  
Michela Florio ◽  
Luigi Capasso ◽  
Alessandro Olivi ◽  
Carla Vitiello ◽  
Antonio Leone ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document