Conventional Versus Stereotactic Image-guided Pedicle Screw Placement During Posterior Lumbar Fusions

Spine ◽  
2019 ◽  
Vol 44 (21) ◽  
pp. E1272-E1280
Author(s):  
Arjun V. Pendharkar ◽  
Paymon G. Rezaii ◽  
Allen L. Ho ◽  
Eric S. Sussman ◽  
Anand Veeravagu ◽  
...  
Spine ◽  
2012 ◽  
Vol 37 (3) ◽  
pp. E188-E194 ◽  
Author(s):  
A. Noelle Larson ◽  
Edward R. G. Santos ◽  
David W. Polly ◽  
Charles G. T. Ledonio ◽  
Jonathan N. Sembrano ◽  
...  

2021 ◽  
pp. 155633162110298
Author(s):  
Jessica Dorilio ◽  
Nicole Utah ◽  
Christina Dowe ◽  
Fedan Avrumova ◽  
Daniel Alicea ◽  
...  

Background: Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. Purpose: We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. Methods: Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. Results: Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups in pedicle screw placement accuracy (2D-fluoroscopy group, 96.6%; 3D-MvIGS group, 94.2%). There were no major complications or cases that required revision surgery. Conclusion: The 3D-MvIGS navigation system performed comparably with 2D-fluoroscopy in terms of pedicle screw placement accuracy and operative time. The 3D-MvIGS showed a significant reduction in radiation exposure to patients. In more complex cases or larger cohorts, the true value of greater anatomical visualization can be elucidated.


2017 ◽  
Vol 61 (5) ◽  
Author(s):  
Sven R. Kantelhardt ◽  
Axel Neulen ◽  
Naureen Keric ◽  
Angelika Gutenberg ◽  
Jens Conrad ◽  
...  

2018 ◽  
Vol 28 (4) ◽  
pp. 357-363 ◽  
Author(s):  
Gregory M. Malham ◽  
Rhiannon M. Parker

OBJECTIVEImage guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors’ early experience with the use of SpineMask for “K-wireless” placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion.METHODSForty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle.RESULTSFourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%). Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%). The radiological accuracy of the SpineMask tracker was 97% (197/204 screws). No patients suffered neural injury or required postoperative screw revision.CONCLUSIONSThe noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.


Author(s):  
Xinghuo Wu ◽  
Rong Liu ◽  
Song Xu ◽  
Cao Yang ◽  
Shuhua Yang ◽  
...  

This study aimed to evaluate the safety and accuracy of mixed reality–based intraoperative three-dimensional navigated pedicle screws in three-dimensional printed model of fractured upper cervical spine. A total of 27 cervical model from patients of upper cervical spine fractures formed the study group. All the C1 and C2 pedicle screws were inserted under mixed reality–based intraoperative three-dimensional image-guided navigation system. The accuracy and safety of the pedicle screw placement were evaluated on the basis of postoperative computerized tomography scans. A total of 108 pedicle screws were properly inserted into the cervical three-dimensional models under mixed reality–based navigation, including 54 C1 pedicle screws and 54 C2 pedicle screws. Analysis of the dimensional parameters of each pedicle at C1/C2 level showed no statistically significant differences in the ideal and the actual entry points, inclined angles, and tailed angles. No screw was misplaced outside the pedicle of the three-dimensional printed model, and no ionizing X-ray radiation was used during screw placement under navigation. It is easy and safe to place C1/C2 pedicle screws under MR surgical navigation. Mixed reality–based navigation is feasible within upper cervical spinal fractures with improved safety and accuracy of C1/C2 pedicle screw insertion.


2015 ◽  
Vol 15 (3) ◽  
pp. 467-476 ◽  
Author(s):  
Yu-Mi Ryang ◽  
Jimmy Villard ◽  
Thomas Obermüller ◽  
Benjamin Friedrich ◽  
Petra Wolf ◽  
...  