Outcomes of Descemet Stripping Endothelial Keratoplasty in Eyes With Pars Plana Versus Anterior Chamber Glaucoma Drainage Devices

Cornea ◽  
2019 ◽  
Vol 38 (11) ◽  
pp. 1364-1369 ◽  
Author(s):  
Joann J. Kang ◽  
David C. Rittterband ◽  
Kevin Lai ◽  
Ruth E. Eisenberg ◽  
Jeffrey M. Liebmann ◽  
...  
2019 ◽  
Vol 28 (7) ◽  
pp. 601-605 ◽  
Author(s):  
Joann J. Kang ◽  
David C. Ritterband ◽  
Richard T. Atallah ◽  
Jeffrey M. Liebmann ◽  
John A. Seedor

2021 ◽  
pp. bjophthalmol-2020-318092
Author(s):  
Rashmi Deshmukh ◽  
Sridevi Nair ◽  
Darren Shu Jeng Ting ◽  
Tushar Agarwal ◽  
Jacqueline Beltz ◽  
...  

Graft detachment is the most common complication of endothelial keratoplasty. With the ongoing advancements in the field of endothelial keratoplasty, our understanding of risk factors of graft detachments and its management has been evolving. Various prevention measures have been described in literature including presoaking the donor graft, anterior chamber tamponade, venting incisions, sutures to prevent dislocation of graft. Management of a detached graft involves secondary interventions such as rebubbling, suturing and regrafts. In this review, we discuss graft detachment in different types of endothelial keratoplasty techniques including Descemet stripping endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and Descemet’s membrane endothelial keratoplasty; with emphasis on incidence, risk factors, preventive measures and their management.


Eye ◽  
2021 ◽  
Author(s):  
Inês C. F. Pereira ◽  
Rosanne van de Wijdeven ◽  
Hans M. Wyss ◽  
Henny J. M. Beckers ◽  
Jaap M. J. den Toonder

AbstractGlaucoma is a progressive optic neuropathy that is the second leading cause of preventable blindness worldwide, after cataract formation. A rise in the intraocular pressure (IOP) is considered to be a major risk factor for glaucoma and is associated with an abnormal increase of resistance to aqueous humour outflow from the anterior chamber. Glaucoma drainage devices have been developed to provide an alternative pathway through which aqueous humour can effectively exit the anterior chamber, thereby reducing IOP. These devices include the traditional aqueous shunts with tube-plate design, as well as more recent implants, such as the trabeculectomy-modifying EX-PRESS® implant and the new minimally invasive glaucoma surgery (MIGS) devices. In this review, we will describe each implant in detail, focusing on their efficacy in reducing IOP and safety profile. Additionally, a critical and evidence-based comparison between these implants will be provided. Finally, we will propose potential developments that may help to improve the performance of current devices.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Enchi Kristina Chang ◽  
Sanchay Gupta ◽  
Marika Chachanidze ◽  
John B. Miller ◽  
Ta Chen Chang ◽  
...  

Abstract Purpose The purpose of this study is to report the safety and efficacy of pars plana glaucoma drainage devices with pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement in patients with refractory glaucoma. Methods Retrospective case series of 28 eyes of 28 patients who underwent combined pars plana glaucoma drainage device and pars plana vitrectomy between November 2016 and September 2019 at Massachusetts Eye and Ear. Main outcome measures were intraocular pressure (IOP), glaucoma medication burden, best corrected visual acuity, and complications. Statistical tests were performed with R and included Kaplan-Meier analyses, Wilcoxon paired signed-rank tests, and Fisher tests. Results Mean IOP decreased from 22.8 mmHg to 11.8 mmHg at 1.5 years (p = 0.002), and mean medication burden decreased from 4.3 to 2.1 at 1.5 years (p = 0.004). Both IOP and medication burden were significantly lower at all follow-up time points. The probability of achieving 5 < IOP ≤ 18 mmHg with at least 20% IOP reduction from preoperative levels was 86.4% at 1 year and 59.8% at 1.5 years. At their last visit, three eyes (10.7%) achieved complete success with IOP reduction as above without medications, and 14 eyes (50.0%) achieved qualified success with medications. Hypotony was observed in 1 eye (3.6%) prior to 3 months postoperatively and 0 eyes after 3 months. Visual acuity was unchanged or improved in 23 eyes (82.1%) at their last follow-up. Two patients had a visual acuity decrease of > 2 lines. Two eyes required subsequent pars plana vitrectomies for tube obstruction, and one eye had transient hypotony. Conclusions The results of pars plana glaucoma drainage device and pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement are promising, resulting in significant IOP and medication-burden reductions through postoperative year 1.5 without additional risk of postoperative complications. Inserting glaucoma drainage devices into an existing vitrectomy sclerotomy site may potentially save surgical time by obviating the need to create another sclerotomy for tube placement and suture one of the vitrectomy ports.


2021 ◽  
pp. 247412642110284
Author(s):  
Srinath Soundararajan ◽  
Cason B. Robbins ◽  
Henry L. Feng ◽  
Sharon Fekrat

Purpose: This work describes the clinical management and outcomes in cases of presumed infectious endophthalmitis following intravitreal injection at a tertiary academic medical center. Methods: A retrospective review took place of eyes that presented to the Duke Eye Center over a 9-year period and were diagnosed with intravitreal injection–related endophthalmitis. Clinical presentation, management, microbiologic yield, visual outcomes, and complications were abstracted from medical records. Results: Of 23 eyes diagnosed with postinjection endophthalmitis, 52.2% underwent anterior chamber tap (33.3% of which first underwent dry needle vitreous tap), 47.8% underwent needle vitreous tap, 17.4% underwent neither, and none underwent pars plana vitrectomy (PPV) for initial management. Subsequent PPV was performed in 6 eyes (26.1%). Mean visual acuity (VA) improved by 50 Early Treatment Diabetic Retinopathy Study letters at 6 months. Eyes that underwent initial anterior chamber tap had worse presenting VA than those that did not ( P = .01). Eyes undergoing subsequent PPV had worse VA at presentation ( P = .02) and at 6 months ( P < .001). Eyes presenting with VA of hand motion (20/8000) or worse were more likely to undergo subsequent PPV ( P = .02). Conclusions: Eyes with intravitreal injection–related endophthalmitis presenting with VA of hand motion or worse were more likely to undergo subsequent PPV. Future studies with larger cohorts may reveal whether earlier vitrectomy should be considered in these patients.


Author(s):  
Alireza Khodabande ◽  
Massood Mohammadi ◽  
Hamid Riazi-Esfahani ◽  
Shahab Karami ◽  
Massood Mirghorbani ◽  
...  

Abstract Background To evaluate changes in anterior segment morphology on anterior segment optical coherence tomography (AS-OCT) following pars plana vitrectomy (PPV) without tamponade. Methods Patients who underwent PPV without tamponade for epiretinal membrane were evaluated. Eligible patients underwent intraocular pressure (IOP) measurement and AS-OCT preoperatively as well as 1 month and 6 months post-operatively. Anterior chamber width (ACW), anterior chamber depth (ACD), trabecular iris angle (TIA), angle opening distance at 500 and 750 µm (AOD), and trabecular iris space area at 500 and 750 µm (TISA) at four quadrants were recorded and analyzed. Additionally, the mean values of TIA (MTIA), AOD (MAOD), and TISA (MTISA) for each eye (mean of four quadrants) were analyzed. Results 23 patients completed the study. The mean age of participants was 56.4 ± 3.6 years of age and 13/23 (56%) were female. Mean IOP of patients was 18.1 ± 1.1, 18.3 ± 1.1, and 18.1 ± 1.2 preoperatively,1 month post-operatively, and 6 months post-operatively, respectively. (p = 0.83). No difference was detected post-operatively in measurements of ACW, ACD, MTIA, MAOD500, MAOD750, MTISA500, and MTISA750. Conclusion Pars plana vitrectomy without tamponade was not associated with changes in anterior chamber morphology.


2016 ◽  
Vol 172 ◽  
pp. 58-63 ◽  
Author(s):  
Sarah B. Weissbart ◽  
Kristin M. Hammersmith ◽  
Brandon D. Ayres ◽  
Christopher J. Rapuano ◽  
Parveen K. Nagra ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document