Three-Year Experience Using Near Infrared Spectroscopy Tissue Oximetry Monitoring of Free Tissue Transfers

2011 ◽  
Vol 66 (5) ◽  
pp. 540-545 ◽  
Author(s):  
Matthew H. Steele
Resuscitation ◽  
2013 ◽  
Vol 84 (6) ◽  
pp. 843-847 ◽  
Author(s):  
Joshua C. Reynolds ◽  
David Salcido ◽  
Allison C. Koller ◽  
Matthew L. Sundermann ◽  
Adam Frisch ◽  
...  

2017 ◽  
Vol 22 (2) ◽  
pp. 025001 ◽  
Author(s):  
Martin B. Rasmussen ◽  
Vibeke R. Eriksen ◽  
Bjørn Andresen ◽  
Simon Hyttel-Sørensen ◽  
Gorm Greisen

2021 ◽  
Vol 41 (2) ◽  
pp. 108-111 ◽  
Author(s):  
Duygu Ece Kumbasar ◽  
Ahmed Hagiga ◽  
Omar Dawood ◽  
Juan Enrique Berner ◽  
Adam Blackburn

2004 ◽  
Vol 100 (6) ◽  
pp. 1469-1475 ◽  
Author(s):  
David A. Benaron ◽  
Ilian H. Parachikov ◽  
Shai Friedland ◽  
Roy Soetikno ◽  
John Brock-Utne ◽  
...  

Background The authors evaluated the ability of visible light spectroscopy (VLS) oximetry to detect hypoxemia and ischemia in human and animal subjects. Unlike near-infrared spectroscopy or pulse oximetry (SpO2), VLS tissue oximetry uses shallow-penetrating visible light to measure microvascular hemoglobin oxygen saturation (StO2) in small, thin tissue volumes. Methods In pigs, StO2 was measured in muscle and enteric mucosa during normoxia, hypoxemia (SpO2 = 40-96%), and ischemia (occlusion, arrest). In patients, StO2 was measured in skin, muscle, and oral/enteric mucosa during normoxia, hypoxemia (SpO2 = 60-99%), and ischemia (occlusion, compression, ventricular fibrillation). Results In pigs, normoxic StO2 was 71 +/- 4% (mean +/- SD), without differences between sites, and decreased during hypoxemia (muscle, 11 +/- 6%; P < 0.001) and ischemia (colon, 31 +/- 11%; P < 0.001). In patients, mean normoxic StO2 ranged from 68 to 77% at different sites (733 measures, 111 subjects); for each noninvasive site except skin, variance between subjects was low (e.g., colon, 69% +/- 4%, 40 subjects; buccal, 77% +/- 3%, 21 subjects). During hypoxemia, StO2 correlated with SpO2 (animals, r2 = 0.98; humans, r2 = 0.87). During ischemia, StO2 initially decreased at -1.3 +/- 0.2%/s and decreased to zero in 3-9 min (r2 = 0.94). Ischemia was distinguished from normoxia and hypoxemia by a widened pulse/VLS saturation difference (Delta < 30% during normoxia or hypoxemia vs. Delta > 35% during ischemia). Conclusions VLS oximetry provides a continuous, noninvasive, and localized measurement of the StO2, sensitive to hypoxemia, regional, and global ischemia. The reproducible and narrow StO2 normal range for oral/enteric mucosa supports use of this site as an accessible and reliable reference point for the VLS monitoring of systemic flow.


Sign in / Sign up

Export Citation Format

Share Document