scholarly journals Acquisition of the dorsal structures in chordate amphioxus

Open Biology ◽  
2016 ◽  
Vol 6 (6) ◽  
pp. 160062 ◽  
Author(s):  
Arseniy R. Morov ◽  
Tharcisse Ukizintambara ◽  
Rushan M. Sabirov ◽  
Kinya Yasui

Acquisition of dorsal structures, such as notochord and hollow nerve cord, is likely to have had a profound influence upon vertebrate evolution. Dorsal formation in chordate development thus has been intensively studied in vertebrates and ascidians. However, the present understanding does not explain how chordates acquired dorsal structures. Here we show that amphioxus retains a key clue to answer this question. In amphioxus embryos, maternal nodal mRNA distributes asymmetrically in accordance with the remodelling of the cortical cytoskeleton in the fertilized egg, and subsequently lefty is first expressed in a patch of blastomeres across the equator where wnt8 is expressed circularly and which will become the margin of the blastopore. The lefty domain co-expresses zygotic nodal by the initial gastrula stage on the one side of the blastopore margin and induces the expression of goosecoid , not-like, chordin and brachyury1 genes in this region, as in the oral ectoderm of sea urchin embryos, which provides a basis for the formation of the dorsal structures. The striking similarity in the gene regulations and their respective expression domains when comparing dorsal formation in amphioxus and the determination of the oral ectoderm in sea urchin embryos suggests that chordates derived from an ambulacrarian-type blastula with dorsoventral inversion.

2003 ◽  
Vol 262 (1) ◽  
pp. 107-118 ◽  
Author(s):  
Vincenzo Cavalieri ◽  
Giovanni Spinelli ◽  
Maria Di Bernardo

BioEssays ◽  
1990 ◽  
Vol 12 (3) ◽  
pp. 115-119 ◽  
Author(s):  
Brian T. Livingston ◽  
Fred H. Wilt

1967 ◽  
Vol 18 (01/02) ◽  
pp. 198-210 ◽  
Author(s):  
Ronald S Reno ◽  
Walter H Seegers

SummaryA two-stage assay procedure was developed for the determination of the autoprothrombin C titre which can be developed from prothrombin or autoprothrombin III containing solutions. The proenzyme is activated by Russell’s viper venom and the autoprothrombin C activity that appears is measured by its ability to shorten the partial thromboplastin time of bovine plasma.Using the assay, the autoprothrombin C titre was determined in the plasma of several species, as well as the percentage of it remaining in the serum from blood clotted in glass test tubes. Much autoprothrombin III remains in human serum. With sufficient thromboplastin it was completely utilized. Plasma from selected patients with coagulation disorders was assayed and only Stuart plasma was abnormal. In so-called factor VII, IX, and P.T.A. deficiency the autoprothrombin C titre and thrombin titre that could be developed was normal. In one case (prethrombin irregularity) practically no thrombin titre developed but the amount of autoprothrombin C which generated was in the normal range.Dogs were treated with Dicumarol and the autoprothrombin C titre that could be developed from their plasmas decreased until only traces could be detected. This coincided with a lowering of the thrombin titre that could be developed and a prolongation of the one-stage prothrombin time. While the Dicumarol was acting, the dogs were given an infusion of purified bovine prothrombin and the levels of autoprothrombin C, thrombin and one-stage prothrombin time were followed for several hours. The tests became normal immediately after the infusion and then went back to preinfusion levels over a period of 24 hrs.In other dogs the effect of Dicumarol was reversed by giving vitamin K1 intravenously. The effect of the vitamin was noticed as early as 20 min after administration.In response to vitamin K the most pronounced increase was with that portion of the prothrombin molecule which yields thrombin. The proportion of that protein with respect to the precursor of autoprothrombin C increased during the first hour and then started to go down and after 3 hrs was equal to the proportion normally found in plasma.


1969 ◽  
Vol 61 (2) ◽  
pp. 219-231 ◽  
Author(s):  
V. H. Asfeldt

ABSTRACT This is an investigation of the practical clinical value of the one mg dexamethasone suppression test of Nugent et al. (1963). The results, evaluated from the decrease in fluorimetrically determined plasma corticosteroids in normal subjects, as well as in cases of exogenous obesity, hirsutism and in Cushing's syndrome, confirm the findings reported in previous studies. Plasma corticosteroid reduction after one mg of dexamethasone in cases of stable diabetes was not significantly different from that observed in control subjects, but in one third of the insulin-treated diabetics only a partial response was observed, indicating a slight hypercorticism in these patients. An insufficient decrease in plasma corticosteroids was observed in certain other conditions (anorexia nervosa, pituitary adenoma, patients receiving contraceptive or anticonvulsive treatment) with no hypercorticism. The physiological significance of these findings is discussed. It is concluded that the test, together with a determination of the basal urinary 17-ketogenic steroid excretion, is suitable as the first diagnostic test in patients in whom Cushing's syndrome is suspected. In cases of insufficient suppression of plasma corticosteroids, further studies, including the suppression test of Liddle (1960), must be carried out.


2020 ◽  
Vol 17 ◽  
Author(s):  
Houli Li ◽  
Di Zhang ◽  
Xiaoliang Cheng ◽  
Qiaowei Zheng ◽  
Kai Cheng ◽  
...  

Background: The trough concentration (Cmin) of Imatinib (IM) is closely related to the treatment outcomes and adverse reactions of patients with gastrointestinal stromal tumors (GIST). However, the drug plasma level has great interand intra-individual variability, and therapeutic drug monitoring (TDM) is highly recommended. Objective: To develop a novel, simple, and economical two-dimensional liquid chromatography method with ultraviolet detector (2D-LC-UV) for simultaneous determination of IM and its major active metabolite, N-demethyl imatinib (NDIM) in human plasma, and then apply the method for TDM of the drug. Method: Sample was processed by simple protein precipitation. Two target analytes were separated on the one-dimension column, captured on the middle column, and then transferred to the two-dimension column for further analysis. The detection was performed at 264 nm. The column temperature was maintained at 40˚C and the injection volume was 500 μL. Totally 32 plasma samples were obtained from patients with GIST who were receiving IM. Method: Sample was processed by simple protein precipitation. Two target analytes were separated on the one-dimension column, captured on the middle column, and then transferred to the two-dimension column for further analysis. The detection was performed at 264 nm. The column temperature was maintained at 40˚C and the injection volume was 500 μL. Totally 32 plasma samples were obtained from patients with GIST who were receiving IM. Conclusion: The novel 2D-LC-UV method is simple, stable, highly automated and independent of specialized technicians, which greatly increases the real-time capability of routine TDM for IM in hospital.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4842
Author(s):  
Waldemar Kamiński

Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the controlled points (CPs). The reference sensor is the one that is placed at the point that (in theoretical assumptions) is not a subject to vertical displacements and the displacements of controlled points are determined according to its height. The hydrostatic levelling rule comes from the Bernoulli’s law. While using the Bernoulli’s principle in hydrostatic levelling, the following components have to be taken into account: atmospheric pressure, force of gravity, density of liquid used in sensors places at CPs. The parameters mentioned above are determined with some mean errors that influence on the accuracy assessment of vertical displacements. In the subject’s literature, there are some works describing the individual accuracy analyses of the components mentioned above. In this paper, the author proposes the concept of comprehensive determination of mean error of vertical displacement (of each CPs), calculated from the mean errors’ values of components dedicated for specific HLS. The formulas of covariances’ matrix were derived and they enable to make the accuracy assessment of the calculations’ results. The author also presented the subject of modelling of vertical displacements’ gained values. The dependences, enabling to conduct the statistic tests of received model’s parameters, were implemented. The conducted tests make it possible to verify the correctness of used theoretical models of the examined object treated as the rigid body. The practical analyses were conducted for two simulated variants of sensors’ connections in HLS. Variant no. I is the sensors’ serial connection. Variant no. II relies on the connection of each CPs with the reference sensor. The calculations’ results show that more detailed value estimations of the vertical displacements can be obtained using variant no. II.


Sign in / Sign up

Export Citation Format

Share Document