scholarly journals Achieving better than 3 Å resolution by single particle cryo-EM at 200 keV

2017 ◽  
Author(s):  
Mark A. Herzik ◽  
Mengyu Wu ◽  
Gabriel C. Lander

AbstractTechnical and methodological advances in single-particle cryo-electron microscopy (cryo-EM) have expanded the technique into a resolution regime that was previously only attainable by X-ray crystallography. Although single-particle cryo-EM has proven to be a useful technique for determining the structures of biomedically relevant molecules at near-atomic resolution, nearly 98% of the structures resolved to better than 4 Å resolution have been determined using 300 keV transmission electron microscopes (TEMs). We demonstrate that it is possible to obtain cryo-EM reconstructions of macromolecular complexes at a range of sizes to better than 3 Å resolution using a 200 keV TEM. These structures are of sufficient quality to unambiguously assign amino acid rotameric conformations and identify ordered water molecules, features previously thought only to be resolvable using TEMs operating at 300 keV.

2016 ◽  
Vol 62 (3) ◽  
pp. 383-394
Author(s):  
Mariusz Czarnocki-Cieciura ◽  
Marcin Nowotny

For many years two techniques have dominated structural biology – X-ray crystallography and NMR spectroscopy. Traditional cryo-electron microscopy of biological macromolecules produced macromolecular reconstructions at resolution limited to 6–10 Å. Recent development of transmission electron microscopes, in particular the development of direct electron detectors, and continuous improvements in the available software, have led to the “resolution revolution” in cryo-EM. It is now possible to routinely obtain near-atomic-resolution 3D maps of intact biological macromolecules as small as ~100 kDa. Thus, cryo-EM is now becoming the method of choice for structural analysis of many complex assemblies that are unsuitable for structure determination by other methods.


Author(s):  
Catherine Vénien-Bryan ◽  
Zhuolun Li ◽  
Laurent Vuillard ◽  
Jean Albert Boutin

The invention of the electron microscope has greatly enhanced the view scientists have of small structural details. Since its implementation, this technology has undergone considerable evolution and the resolution that can be obtained for biological objects has been extended. In addition, the latest generation of cryo-electron microscopes equipped with direct electron detectors and software for the automated collection of images, in combination with the use of advanced image-analysis methods, has dramatically improved the performance of this technique in terms of resolution. While calculating a sub-10 Å resolution structure was an accomplishment less than a decade ago, it is now common to generate structures at sub-5 Å resolution and even better. It is becoming possible to relatively quickly obtain high-resolution structures of biological molecules, in particular large ones (>500 kDa) which, in some cases, have resisted more conventional methods such as X-ray crystallography or nuclear magnetic resonance (NMR). Such newly resolved structures may, for the first time, shed light on the precise mechanisms that are essential for cellular physiological processes. The ability to attain atomic resolution may support the development of new drugs that target these proteins, allowing medicinal chemists to understand the intimacy of the relationship between their molecules and targets. In addition, recent developments in cryo-electron microscopy combined with image analysis can provide unique information on the conformational variability of macromolecular complexes. Conformational flexibility of macromolecular complexes can be investigated using cryo-electron microscopy and multiconformation reconstruction methods. However, the biochemical quality of the sample remains the major bottleneck to routine cryo-electron microscopy-based determination of structures at very high resolution.


2017 ◽  
Vol 114 (42) ◽  
pp. 11139-11144 ◽  
Author(s):  
Nadav Elad ◽  
Giuliano Bellapadrona ◽  
Lothar Houben ◽  
Irit Sagi ◽  
Michael Elbaum

Metal ions play essential roles in many aspects of biological chemistry. Detecting their presence and location in proteins and cells is important for understanding biological function. Conventional structural methods such as X-ray crystallography and cryo-transmission electron microscopy can identify metal atoms on protein only if the protein structure is solved to atomic resolution. We demonstrate here the detection of isolated atoms of Zn and Fe on ferritin, using cryogenic annular dark-field scanning transmission electron microscopy (cryo-STEM) coupled with single-particle 3D reconstructions. Zn atoms are found in a pattern that matches precisely their location at the ferroxidase sites determined earlier by X-ray crystallography. By contrast, the Fe distribution is smeared along an arc corresponding to the proposed path from the ferroxidase sites to the mineral nucleation sites along the twofold axes. In this case the single-particle reconstruction is interpreted as a probability distribution function based on the average of individual locations. These results establish conditions for detection of isolated metal atoms in the broader context of electron cryo-microscopy and tomography.


2019 ◽  
Vol 20 (17) ◽  
pp. 4186 ◽  
Author(s):  
Emeka Nwanochie ◽  
Vladimir N. Uversky

Traditionally, X-ray crystallography and NMR spectroscopy represent major workhorses of structural biologists, with the lion share of protein structures reported in protein data bank (PDB) being generated by these powerful techniques. Despite their wide utilization in protein structure determination, these two techniques have logical limitations, with X-ray crystallography being unsuitable for the analysis of highly dynamic structures and with NMR spectroscopy being restricted to the analysis of relatively small proteins. In recent years, we have witnessed an explosive development of the techniques based on Cryo-electron microscopy (Cryo-EM) for structural characterization of biological molecules. In fact, single-particle Cryo-EM is a special niche as it is a technique of choice for the structural analysis of large, structurally heterogeneous, and dynamic complexes. Here, sub-nanometer atomic resolution can be achieved (i.e., resolution below 10 Å) via single-particle imaging of non-crystalline specimens, with accurate 3D reconstruction being generated based on the computational averaging of multiple 2D projection images of the same particle that was frozen rapidly in solution. We provide here a brief overview of single-particle Cryo-EM and show how Cryo-EM has revolutionized structural investigations of membrane proteins. We also show that the presence of intrinsically disordered or flexible regions in a target protein represents one of the major limitations of this promising technique.


2019 ◽  
Author(s):  
Mengyu Wu ◽  
Gabriel C. Lander ◽  
Mark A. Herzik

AbstractAlthough the advent of direct electron detectors (DEDs) and software developments have enabled the routine use of single-particle cryogenic electron microscopy (cryo-EM) for structure determination of well-behaved specimens to high-resolution, there nonetheless remains a discrepancy between the resolutions attained for biological specimens and the information limits of modern transmission electron microscopes (TEMs). Instruments operating at 300 kV equipped with DEDs are the current paradigm for high-resolution single-particle cryo-EM, while 200 kV TEMs remain comparatively underutilized for purposes beyond sample screening. Here, we expand upon our prior work and demonstrate that one such 200 kV microscope, the Talos Arctica, equipped with a K2 DED is capable of determining structures of macromolecules to as high as ∼1.7 Å resolution. At this resolution, ordered water molecules are readily assigned and holes in aromatic residues can be clearly distinguished in the reconstructions. This work emphasizes the utility of 200 keV for high-resolution single-particle cryo-EM and applications such as structure-based drug design.


Author(s):  
Kaiming Zhang ◽  
Grigore D. Pintilie ◽  
Shanshan Li ◽  
Michael F. Schmid ◽  
Wah Chiu

AbstractBreakthroughs in single-particle cryo-electron microscopy (cryo-EM) technology have made near-atomic resolution structure determination possible. Here, we report a ∼1.35-Å structure of apoferritin reconstructed from images recorded on a Gatan K3 or a Thermo Fisher Falcon 4 detector in a commonly available 300-kV Titan Krios microscope (G3i) equipped with or without a Gatan post-column energy filter. Our results demonstrate that the atomic-resolution structure determination can be achieved by single-particle cryo-EM with a fraction of a day of automated data collection. These structures resolve unambiguously each heavy atom (C, N, O, and S) in the amino acid side chains with an indication of hydrogen atoms’ presence and position, as well as the unambiguous existence of multiple rotameric configurations for some residues. We also develop a statistical and chemical based protocol to assess the positions of the water molecules directly from the cryo-EM map. In addition, we have introduced a B’ factor equivalent to the conventional B factor traditionally used by crystallography to annotate the atomic resolution model for determined structures. Our findings will be of immense interest among protein and medicinal scientists engaging in both basic and translational research.


2020 ◽  
Author(s):  
Blake T. Riley ◽  
Stephanie A. Wankowicz ◽  
Saulo H. P. de Oliveira ◽  
Gydo C. P. van Zundert ◽  
Daniel Hogan ◽  
...  

AbstractNew X-ray crystallography and cryo-electron microscopy (cryo-EM) approaches yield vast amounts of structural data from dynamic proteins and their complexes. Modeling the full conformational ensemble can provide important biological insights, but identifying and modeling an internally consistent set of alternate conformations remains a formidable challenge. qFit efficiently automates this process by generating a parsimonious multiconformer model. We refactored qFit from a distributed application into software that runs efficiently on a small server, desktop, or laptop. We describe the new qFit 3 software and provide some examples. qFit 3 is open-source under the MIT license, and is available at https://github.com/ExcitedStates/qfit-3.0.


Author(s):  
John C. Russ ◽  
Nicholas C. Barbi

The rapid growth of interest in attaching energy-dispersive x-ray analysis systems to transmission electron microscopes has centered largely on microanalysis of biological specimens. These are frequently either embedded in plastic or supported by an organic film, which is of great importance as regards stability under the beam since it provides thermal and electrical conductivity from the specimen to the grid.Unfortunately, the supporting medium also produces continuum x-radiation or Bremsstrahlung, which is added to the x-ray spectrum from the sample. It is not difficult to separate the characteristic peaks from the elements in the specimen from the total continuum background, but sometimes it is also necessary to separate the continuum due to the sample from that due to the support. For instance, it is possible to compute relative elemental concentrations in the sample, without standards, based on the relative net characteristic elemental intensities without regard to background; but to calculate absolute concentration, it is necessary to use the background signal itself as a measure of the total excited specimen mass.