Multi-use high/low-temperature and pressure compatible portable chamber forin situgrazing-incidence X-ray scattering studies

2013 ◽  
Vol 20 (3) ◽  
pp. 474-481 ◽  
Author(s):  
Pilar Ferrer ◽  
Juan Rubio-Zuazo ◽  
Catherine Heyman ◽  
Fatima Esteban-Betegón ◽  
Germán R. Castro

The multipurpose portable ultra-high-vacuum-compatible chamber described in detail in this article has been designed to carry out grazing-incidence X-ray scattering techniques on the BM25-SpLine CRG beamline at the ESRF. The chamber has a cylindrical form, built on a 360° beryllium double-ended conflate flange (CF) nipple. The main advantage of this chamber design is the wide sample temperature range, which may be varied between 60 and 1000 K. Other advantages of using a cylinder are that the wall thickness is reduced to a minimum value, keeping maximal solid angle accessibility and keeping wall absorption of the incoming X-ray beam constant. The heat exchanger is a customized compact liquid-nitrogen (LN2) continuous-flow cryostat. LN2 is transferred from a storage Dewar through a vacuum-isolated transfer line to the heat exchanger. The sample is mounted on a molybdenum support on the heat exchanger, which is equipped with a BORALECTRIC heater element. The chamber versatility extends to the operating pressure, ranging from ultra-high vacuum (<10−10 mbar) to high pressure (up to 3 × 103 mbar). In addition, it is equipped with several CF ports to allocate auxiliary components such as capillary gas-inlet, viewports, leak valves, ion gun, turbo pump,etc., responding to a large variety of experiment requirements. A movable slits set-up has been foreseen to reduce the background and diffuse scattering produced at the beryllium wall. Diffraction data can be recorded either with a point detector or with a bi-dimensional CCD detector, or both detectors simultaneously. The system has been designed to carry out a multitude of experiments in a large variety of environments. The system feasibility is demonstrated by showing temperature-dependence grazing-incidence X-ray diffraction and conductivity measurements on a 20 nm-thick La0.7Ca0.3MnO3thin film grown on a SrTiO3(001) substrate.

1993 ◽  
Vol 37 ◽  
pp. 413-418
Author(s):  
Joanne Levine Parrill ◽  
Jerome B. Cohen ◽  
Yip-Wah Chung

AbstractAn ultra-high vacuum chamber designed for in situ grazing incidence small angle x-ray scattering (GISAXS) surface analysis is described. Unique features of this equipment are the precision rotary feedthrough for angular alignment of the sample, the sample heating design, the Be window arrangement, and the compatibility of this chamber with both a rotating anode and a synchrotron beamline. This chamber was used as part of a GISAXS camera utilizing a 18 kW Rigaku rotating anode, pin-hole collimation, and a position sensitive detector. The resolution of this camera was 0.007 A-1 with a 1.4 mm wide beamstop and CuKα


2009 ◽  
Vol 140 ◽  
pp. 41-58 ◽  
Author(s):  
Christopher A. Lucas ◽  
Michael Cormack ◽  
Mark E. Gallagher ◽  
Alexander Brownrigg ◽  
Paul Thompson ◽  
...  

1999 ◽  
Vol 602 ◽  
Author(s):  
M. Petit ◽  
L. J. Martinez-Miranda ◽  
M. Rajeswari ◽  
A. Biswas ◽  
D. J. Kang ◽  
...  

AbstractWe have performed depth profile analyses of the lattice parameters in epitaxial thin films of La1−xCaxMno3 (LCMO), where x = 0.33 or 0.3, to understand the evolution of strain relaxation processes in these materials. The analyses were done using Grazing Incidence X-ray Scattering (GIXS) on films of different thicnesses on two different substrates, (100) oriented LaAlO3 (LAO), with a lattice mismatch of ∼2% and (110) oriented NGO, with a lattice mismatch of less than 0.1%. Films grown on LAO can exhibit up to three in-plane strained lattice constants, corresponding to a slight orthorhombic distortion of the crystal, as well as near-surface and columnar lattice relaxation. As a function of film thickness, a crossover from a strained film to a mixture of strained and relaxed regions in the film occurs in the range of 700 Å. The structural evolution at this thickness coincides with a change in the resistivity curve near the metalinsulator transition. The in-plane compressive strain has a range of 0.2 – 1.5%, depending on the film thickness for filsm in the range of 400 - 1500 A.


2014 ◽  
Vol 115 (20) ◽  
pp. 204311 ◽  
Author(s):  
Nie Zhao ◽  
Chunming Yang ◽  
Qian Zhang ◽  
Xueming Lu ◽  
Yuzhu Wang ◽  
...  

1999 ◽  
Vol 86 (12) ◽  
pp. 6763-6769 ◽  
Author(s):  
Markus Rauscher ◽  
Rogerio Paniago ◽  
Hartmut Metzger ◽  
Zoltan Kovats ◽  
Jan Domke ◽  
...  

2013 ◽  
Vol 21 (1) ◽  
pp. 1-4 ◽  
Author(s):  
Hiroyuki Kishimoto ◽  
Yuya Shinohara ◽  
Yoshio Suzuki ◽  
Akihisa Takeuchi ◽  
Naoto Yagi ◽  
...  

A pinhole-type two-dimensional ultra-small-angle X-ray scattering set-up at a so-called medium-length beamline at SPring-8 is reported. A long sample-to-detector distance, 160.5 m, can be used at this beamline and a small-angle resolution of 0.25 µm−1was thereby achieved at an X-ray energy of 8 keV.


2012 ◽  
Vol 97 ◽  
pp. 109-118 ◽  
Author(s):  
Jose Abad ◽  
Nieves Espinosa ◽  
Pilar Ferrer ◽  
Rafael García-Valverde ◽  
Carmen Miguel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document