Uridine as a new scavenger for synchrotron-based structural biology techniques

2017 ◽  
Vol 24 (1) ◽  
pp. 53-62 ◽  
Author(s):  
Eva Crosas ◽  
Albert Castellvi ◽  
Isidro Crespo ◽  
Daniel Fulla ◽  
Fernando Gil-Ortiz ◽  
...  

Macromolecular crystallography (MX) and small-angle X-ray scattering (SAXS) studies on proteins at synchrotron light sources are commonly limited by the structural damage produced by the intense X-ray beam. Several effects, such as aggregation in protein solutions and global and site-specific damage in crystals, reduce the data quality or even introduce artefacts that can result in a biologically misguiding structure. One strategy to reduce these negative effects is the inclusion of an additive in the buffer solution to act as a free radical scavenger. Here the properties of uridine as a scavenger for both SAXS and MX experiments on lysozyme at room temperature are examined. In MX experiments, upon addition of uridine at 1 M, the critical dose D 1/2 is increased by a factor of ∼1.7, a value similar to that obtained in the presence of the most commonly used scavengers such as ascorbate and sodium nitrate. Other figures of merit to assess radiation damage show a similar trend. In SAXS experiments, the scavenging effect of 40 mM uridine is similar to that of 5% v/v glycerol, and greater than 2 mM DTT and 1 mM ascorbic acid. In all cases, the protective effect of uridine is proportional to its concentration.

2016 ◽  
Vol 23 (1) ◽  
pp. 141-151 ◽  
Author(s):  
A. G. Stepanov ◽  
C. P. Hauri

High-brightness X-ray radiation produced by third-generation synchrotron light sources (TGLS) has been used for numerous time-resolved investigations in many different scientific fields. The typical time duration of X-ray pulses delivered by these large-scale machines is about 50–100 ps. A growing number of time-resolved studies would benefit from X-ray pulses with two or three orders of magnitude shorter duration. Here, techniques explored in the past for shorter X-ray pulse emission at TGLS are reviewed and the perspective towards the realisation of picosecond and sub-picosecond X-ray pulses are discussed.


2014 ◽  
Vol 21 (5) ◽  
pp. 961-967 ◽  
Author(s):  
Xiaobiao Huang ◽  
Thomas Rabedeau ◽  
James Safranek

Approaches to generating short X-ray pulses in synchrotron light sources are discussed. In particular, the method of using a superconducting harmonic cavity to generate simultaneously long and short bunches in storage rings and the approach of injecting short bunches from a linac injector into a storage ring for multi-turn circulation are emphasized. If multi-cell superconducting RF (SRF) cavities with frequencies of ∼1.5 GHz can be employed in storage rings, it would be possible to generate stable, high-flux, short-pulse X-ray beams with pulse lengths of 1–10 ps (FWHM) in present or future storage rings. However, substantial challenges exist in adapting today's high-gradient SRF cavities for high-current storage ring operation. Another approach to generating short X-ray pulses in a storage ring is injecting short-pulse electron bunches from a high-repetition-rate linac injector for circulation. Its performance is limited by the microbunching instability due to coherent synchrotron radiation. Tracking studies are carried out to evaluate its performance. Challenges and operational considerations for this mode are considered.


2016 ◽  
Vol 23 (3) ◽  
pp. 685-693 ◽  
Author(s):  
Michael E. Rutherford ◽  
David J. Chapman ◽  
Thomas G. White ◽  
Michael Drakopoulos ◽  
Alexander Rack ◽  
...  

The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is targeted at two-dimensional integrating detector methods, such as those focused on dynamic radiography and diffraction experiments. The response of a scintillator to periodic synchrotron X-ray excitation is modelled and validated against experimental data collected at the Diamond Light Source (DLS) and European Synchrotron Radiation Facility (ESRF). An upper bound on the dynamic range accessible in a time-resolved experiment for a given bunch separation is calculated for a range of scintillators. New bunch structures are suggested for DLS and ESRF using the highest-performing commercially available crystal LYSO:Ce, allowing time-resolved experiments with an interframe time of 189 ns and a maximum dynamic range of 98 (6.6 bits).


2007 ◽  
Vol 48 (6) ◽  
pp. 495-503 ◽  
Author(s):  
Nakashi SASANO ◽  
Atsushi ENOMOTO ◽  
Yoshio HOSOI ◽  
Yosuke KATSUMURA ◽  
Yoshihisa MATSUMOTO ◽  
...  

2010 ◽  
Vol 293 (1) ◽  
pp. 52-57 ◽  
Author(s):  
N. Sasano ◽  
A. Enomoto ◽  
Y. Hosoi ◽  
Y. Katsumura ◽  
Y. Matsumoto ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document