scholarly journals Modeling and Control Parameters Design for Grid-Connected Inverter System Considering the Effect of PLL and Grid Impedance

IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 40474-40484 ◽  
Author(s):  
Zhiwei Xie ◽  
Yandong Chen ◽  
Wenhua Wu ◽  
Yuancan Xu ◽  
Haining Wang ◽  
...  
2021 ◽  
Vol 19 (02) ◽  
pp. 250-259
Author(s):  
Jakson Paulo Bonaldo ◽  
Jose de Arimateia Olimpio Filho ◽  
Augusto Matheus dos Santos Alonso ◽  
Helmo Kelis Morales Paredes ◽  
Fernando Pinhabel Marafao

2019 ◽  
Vol 9 (2) ◽  
pp. 252 ◽  
Author(s):  
Ziqian Zhang ◽  
Cihan Gercek ◽  
Herwig Renner ◽  
Angèle Reinders ◽  
Lothar Fickert

This article presents an in-situ comparative analysis and power quality tests of a newly developed photovoltaic charging system for e-bikes. The various control methods of the inverter are modeled and a single-phase grid-connected inverter is tested under different conditions. Models are constituted for two current control methods; the proportional resonance and the synchronous rotating frames. In order to determine the influence of the control parameters, the system is analyzed analytically in the time domain as well as in the frequency domain by simulation. The tests indicated the resonance instability of the photovoltaic inverter. The passivity impedance-based stability criterion is applied in order to analyze the phenomenon of resonance instability. In conclusion, the phase-locked loop (PLL) bandwidth and control parameters of the current loop have a major effect on the output admittance of the inverter, which should be adjusted to make the system stable.


2022 ◽  
Vol 9 ◽  
Author(s):  
Fuyun Wu ◽  
Zhuang Sun ◽  
Weiji Xu ◽  
Zhizhou Li ◽  
Jianguo Lyu

Under weak grid conditions, the variation of the grid impedance will affect the steady-state and dynamic performance of the LCL-filtered grid-connected inverter and even make the inverter unstable. To ensure the system stability and further improve the dynamic performance in a weak grid, a control parameter design method with multi-constrains considering the system bandwidth for the current controller and active damping is proposed in this paper. First, based on the current controller and active damping with only grid current feedback, the effects of control parameters and grid impedance on the LCL resonant suppression and the performance of the inverter are analyzed. Moreover, the parameter constraints of the controllers are derived considering the grid impedance, including stability, resonance suppression, and margin constraints. Furthermore, as the system bandwidth affects the dynamic performance of the inverter, combined with the obtained multi-constraints, the optimal control parameters are determined by achieving the maximum bandwidth of the system against the impedance variation. Compared with other two methods, when the proposed method is applied, the system can operate with a better dynamic and steady-state performance. Finally, experiments are performed on a 2 kW three-phase grid-connected inverter in the weak grid, which verify the effectiveness of the parameter design method proposed in this paper.


Sign in / Sign up

Export Citation Format

Share Document