scholarly journals Electric arc recoil – a novel method for reducing lightning strike potential difference for transmission line

IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Yanlei Wang ◽  
Yaojing Luo ◽  
Yuning Chen ◽  
Jufeng Wang ◽  
Yiyi Zhang
2018 ◽  
Vol 197 ◽  
pp. 11001
Author(s):  
Aristo Adi Kusuma ◽  
Putu Agus Aditya Pramana ◽  
Brian Bramantyo S.D.A. Harsono ◽  
Buyung Sofiarto Munir

Based on Java-Bali grid disturbance data, the 66kV transmission lines that is close to or intersect with 150kV or 500kV transmission line is often experienced earth fault due to insulator flashover. The insulator flashover can be caused by indirect lightning strike since lightning strikes tend to strike higher structure. Therefore, this paper will determine the effect of indirect lightning strike on 150kV or 500kV transmission line to 66kV transmission line by modeling and simulation using application of transient analysis. Variation of lightning peak current magnitude and gap between 66kV transmission line and transmission line with higher voltage is performed during simulation. The range of peak current magnitude follows the data from lightning detection systems, while the value of gap follows the data from actual condition. It is found that higher current peak and closer gap will cause higher transient overvoltage on insulator of 66kV transmission line thus insulator flashover may occur more frequent. Addition of earth wire on 66kV transmission line and gap between each transmission by organizing the sag of conductor can be performed to minimize the insulator flashover.


IEEE Access ◽  
2016 ◽  
Vol 4 ◽  
pp. 7241-7250 ◽  
Author(s):  
Yadong Liu ◽  
Gehao Sheng ◽  
Yue Hu ◽  
Yong Qian ◽  
Xiuchen Jiang ◽  
...  

2011 ◽  
Vol 121-126 ◽  
pp. 1269-1273
Author(s):  
Wen Xiu Tang ◽  
Mo Zhang ◽  
Ying Liu ◽  
Xu Fei Lang ◽  
Liang Kuan Zhu

In this paper, a novel method is investigated to detect short-circuit fault signal transmission lines in strong noise environment based on discrete wavelet transform theory. Simulation results show that the method can accurately determine the fault position, can effectively analyze the non-stationary signal and be suitable for transmission line fault occurred after transient signal detection. Furthermore, it can effectively eliminate noise effects of fault signal so as to realize the transmission lines of accurate fault.


Sensors ◽  
2018 ◽  
Vol 18 (2) ◽  
pp. 596 ◽  
Author(s):  
Xinyan Qin ◽  
Gongping Wu ◽  
Jin Lei ◽  
Fei Fan ◽  
Xuhui Ye ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5590
Author(s):  
Małgorzata Musztyfaga-Staszuk

This work presents a comparison of values of the contact resistivity of silicon solar cells obtained using the following methods: the transmission line model method (TLM) and the potential difference method (PD). Investigations were performed with two independent scientific units. The samples were manufactured with silver front electrodes. The co-firing process was performed in an infrared belt furnace in a temperature range of 840 to 960 °C. The electrical properties of a batch of solar cells fabricated in two cycles were investigated. This work focuses on the different metallisation temperatures of co-firing solar cells and measurements were carried out using the methods mentioned. In the TLM and PD methods, the same calculation formulae were used. Moreover, solar cell parameters measured with these methods had the same, similar, or sometimes different but strongly correlated values. Based on an analysis of the selected databases, this article diagnoses the recent and current state of knowledge regarding the employment of the TLM and PD methods and the available hardware base. These methods are of interest to various research centres, groups of specialists dealing with the optimisation of the electrical properties of silicon photovoltaic cells, and designers of measuring instruments.