A Control Method of Dual Active Bridge DC-DC Converters Maintaining Soft-Switching at Different Voltage Ratio

Author(s):  
Takeshi Uchida ◽  
Yoichi Ishizuka ◽  
Daisuke Yamashita ◽  
Toshiro Hirose ◽  
Kazuto Ura
Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 404
Author(s):  
Sara J. Ríos ◽  
Daniel J. Pagano ◽  
Kevin E. Lucas

Currently, high-performance power conversion requirements are of increasing interest in microgrid applications. In fact, isolated bidirectional dc-dc converters are widely used in modern dc distribution systems. The dual active bridge (DAB) dc-dc converter is identified as one of the most promising converter topology for the mentioned applications, due to its benefits of high power density, electrical isolation, bidirectional power flow, zero-voltage switching, and symmetrical structure. This study presents a power management control scheme in order to ensure the power balance of a dc microgrid in stand-alone operation, where the renewable energy source (RES) and the battery energy storage (BES) unit are interfaced by DAB converters. The power management algorithm, as introduced in this work, selects the proper operation of the RES system and BES system, based on load/generation power and state-of-charge of the battery conditions. Moreover, a nonlinear robust control strategy is proposed when the DAB converters are in voltage-mode-control in order to enhance the dynamic performance and robustness of the common dc-bus voltage, in addition to overcoming the instability problems that are caused by constant power loads and the dynamic interactions of power electronic converters. The simulation platform is developed in MATLAB/Simulink, where a photovoltaic system and battery system are selected as the typical RES and BES, respectively. Assessments on the performance of the proposed control scheme are conducted. Comparisons with the other control method are also provided.


Electronics ◽  
2018 ◽  
Vol 7 (10) ◽  
pp. 214 ◽  
Author(s):  
Dong-Min Lee ◽  
Seung-Wook Hyun ◽  
Jin-Wook Kang ◽  
Yong-Su Noh ◽  
Chung-Yuen Won

This paper examines the characteristics of the zero voltage switching (ZVS) and zero voltage transition (ZVT) soft-switching applied in the 3-phase current fed dual active bridge (3P-CFDAB) converter, which combines the advantages of the dual active bridge (DAB) converter and current-fed full bridge (CFFB) converter. When an active clamp circuit is added to the CFFB converter, the circuit configuration of the DAB converter is shown in part of the entire circuit. This allows the use of pulse width modulation (PWM) techniques which combine the PWM techniques of both the DAB converter and CFFB converter. The proposed converter performs both duty and phase control at the same time in order to reduce the circulating current and ripple current of the output capacitor, which are the disadvantages of the CFFB converter and DAB converter. In addition, the ZVS and ZVT soft switching areas were analyzed by means of the phase current and leakage inductor current in each transformers. To verify the principle and feasibility of the proposed operation techniques, a simulation and experiment were implemented with the 3P-CFDAB.


Energies ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 4241 ◽  
Author(s):  
Diana Lopez-Caiza ◽  
Freddy Flores-Bahamonde ◽  
Samir Kouro ◽  
Victor Santana ◽  
Nicolás Müller ◽  
...  

Single-stage voltage step-up inverters, such as the Dual Boost Inverter (DBI), have a large operating range imposed by the high step-up voltage ratio, which together with the converter of non-linearities, makes them a challenge to control. This is particularly the case for grid-connected applications, where several cascaded and independent control loops are necessary for each converter of the DBI. This paper presents a global current control method based on a combination of a linear proportional resonant controller and a non-linear sliding mode controller that simplifies the controller design and implementation. The proposed control method is validated using a grid-connected laboratory prototype. Experimental results show the correct performance of the controller and compliance with power quality standards.


Sign in / Sign up

Export Citation Format

Share Document