Influence on zero-sequence components of autotransformer neutral grounding via small reactance in one 500kV substation

Author(s):  
Li Xiao-hua ◽  
Dai Meisheng ◽  
Xie Yi-si ◽  
Luo Long-bo ◽  
Cai Ze-xiang
Electronics ◽  
2020 ◽  
Vol 9 (12) ◽  
pp. 2052
Author(s):  
Odair de Barros Junior ◽  
Thiago Silva Amorim ◽  
Daniel Carletti ◽  
Anselmo Frizera Neto ◽  
Lucas Frizera Encarnação

The increasing number of electronic loads has introduced several harmonics into the power system, leading to a growth in the importance of filters intended for their mitigation. Thus, it is important to have the knowledge to select operational limits of each new filter connected in the power grid. Likewise, obtaining these harmonics requires robust tracking systems that provide enough information for better filter selectivity. This paper proposes a selective harmonic active filter control based on Fourier linear combiner (FLC) algorithms for a three-phase electrical grid. The presented system is enabled to track each harmonic order and sequence components with great robustness, extracting positive, negative, and zero sequence information from each harmonic for further filter selectivity. It also proposes a new strategy to improve the FLC-based algorithms in tracking frequencies in power grid disturbances. Simulated results of the algorithm and a real-time simulation of a selective active power filter (SAPF) were presented, validating the performance in several scenarios.


2017 ◽  
Vol 53 (11) ◽  
pp. 1-4 ◽  
Author(s):  
K. Wang ◽  
J. Y. Zhang ◽  
Z. Y. Gu ◽  
H. Y. Sun ◽  
Z. Q. Zhu

2017 ◽  
Vol 14 (1) ◽  
pp. 411-420
Author(s):  
W Abitha Memala ◽  
V Rajini

Induction motor stator fault is diagnosed by applying Discrete Wavelet transform on zero sequence components. The single phasing stator fault is created and diagnosed in the induction motor model developed in stationary reference frame, under varying load conditions. The stator inter-turn incipient fault is created and diagnosed in the induction motor experimental setup as well under no load condition. The qdo components are calculated from Park’s equations. The faults can be diagnosed from wavelet transform of the zero sequence current components. PSD is used for diagnosing the fault and the statistical value is used for verifying the result. The energy is calculated using Parseval’s theorem. The energy and the statistical data calculated from the wavelet coefficients of zero sequence current components are used as fault indicators. The energy value is able to reveal the fault severity in the induction motor stator winding. Power spectral Density along with Discrete Wavelet Transform plays very important role in diagnosing the fault.


Author(s):  
Kumarraja Andanapalli ◽  
Monalisa Biswal

Abstract Distance relay are designed with swing blocking/tripping logic to maintain reliable and secure operation of power system. To prevent this from happening, the relay is functioned with a power swing blocking (PSB) logic. However, ensuring proper detection to swing event requires to overcome from the dependable situation such as three-phase fault. The relay refuses to behave normally if both swing and three-phase fault occur simultaneously. Reliable setting is essential to generate trip/block command. Unsymmetrical faults are easily detected during the swing condition due to the presence of negative and zero sequence components, but such components are absent in the case of symmetrical/three-phase fault. As a result, symmetrical fault under blocking condition is unidentified many a times by the distance relay, arising security issues. To improve the relay operation during swing and symmetrical fault conditions, a MOPSVC (multiplication of positive sequence voltage and current) based index is developed in this work. The MOPSVC index helps to discern power swing from three-phase fault. To test the efficacy of the method, a 230 kV, 50 Hz two-area four machine system, and Indian Eastern Regional Grid (IERG) network are considered. Simulation task is conducted using EMTDC/PSCAD software. To investigate the performance of the proposed method, various swing phenomena, faults, CT saturation, switching transients, and the presence of noise cases are considered, and the results demonstrate the robustness of the proposed algorithm. Responses under stressed power system conditions are also investigated, and a report on comparisons with existing methods is provided. Simulated results confirm that the proposed algorithm can balance the dependability and security aspects of the protection logic.


2021 ◽  
Vol 252 ◽  
pp. 01014
Author(s):  
Shi Kejian ◽  
Zhu Yidong ◽  
Zheng Zimo ◽  
Zhang Xinyu ◽  
Tian Ye ◽  
...  

Fault components in the fault path and the non-fault path differ due to the unbalanced distribution of positive, negative and zero-sequence components in the line in the case of a single-phase earth fault in the power distribution network. Therefore, this paper proposes an improved fault section location algorithm based on phase current, which obtains the fault component current by the subtraction of currents before and after the fault and the fundamental wave amplitude of the corresponding current through Fast Fourier Transform (FFT). Meanwhile, considering that the fault section location cannot be completed accurately with the amplitude relationship alone, the Minkowski distance calculation formula is introduced to strengthen the difference between the fault path and the non-fault path, and the relationship between the calculation results of different sections and the threshold is compared by threshold setting to complete the section location. This paper proposes the specific fault section location process and criteria and verifies the feasibility of the algorithm through simulation experiment.