Temperature Distribution Characteristics of a New Superconducting Energy Pipeline Structure with High Security

Author(s):  
Jinhui Luo ◽  
Bin Xiang ◽  
Peng Xue ◽  
Xiaohua Jiang
Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 6057
Author(s):  
Guilong Zhang ◽  
Ziqiang Ma ◽  
Heng Li ◽  
Jinshi Wang

Marangoni condensation is formed due to the surface tension gradient caused by the local temperature or concentration gradient on the condensate surface; thus, the investigation of the surface temperature distribution characteristics is crucial to reveal the condensation mechanism and heat transfer characteristics. Few studies have been conducted on the temperature distribution of the condensate surface. In this study, thermal infrared images were used to measure the temperature distributions of the condensate surface during Marangoni condensation for ethanol–water mixture vapor. The results showed that the surface temperature distribution of the single droplet was uneven, and a large temperature gradient, approximately 15.6 °C/mm, existed at the edge of the condensate droplets. The maximum temperature difference on the droplet surface reached up to 8 °C. During the condensation process, the average surface temperature of a single droplet firstly increased rapidly and then slowly until it approached a certain temperature, whereas that of the condensate surface increased rapidly at the beginning and then changed periodically in a cosine-like curve. The present results will be used to obtain local heat flux and heat transfer coefficients on the condensing surface, and to further establish the relationship between heat transfer and temperature distribution characteristics.


Author(s):  
Zhengang Zhao ◽  
Zhangnan Jiang ◽  
Yang Li ◽  
Chuan Li ◽  
Dacheng Zhang

The temperature of the hot-spots on windings is a crucial factor that can limit the overload capacity of the transformer. Few studies consider the impact of the load on the hot-spot when studying the hot-spot temperature and its location. In this paper, a thermal circuit model based on the thermoelectric analogy method is built to simulate the transformer winding and transformer oil temperature distribution. The hot-spot temperature and its location under different loads are qualitatively analyzed, and the hot-spot location is analyzed and compared to the experimental results. The results show that the hot-spot position on the winding under the rated power appears at 85.88% of the winding height, and the hot-spot position of the winding moves down by 5% in turn at 1.3, 1.48, and 1.73 times the rated power respectively.


Sign in / Sign up

Export Citation Format

Share Document