The Problem of Short-circuit Current Limitation in Energy–saving Systems of Transportation and Electricity Distribution

Author(s):  
Kuznetsov Anatoliy Viktorovich ◽  
Yurenkov Yuriy Petrovich ◽  
Mityaev Andrey Aleksandrovich
2016 ◽  
Vol 31 (2) ◽  
pp. 1278-1288 ◽  
Author(s):  
Zhifang Yang ◽  
Haiwang Zhong ◽  
Qing Xia ◽  
Chongqing Kang

2012 ◽  
Vol 260-261 ◽  
pp. 525-531 ◽  
Author(s):  
Salman Badkubi

This paper presents the comprehensive implementation of Distributed Static Series Compensator (DSSC) to limit the fault currents in power systems. This is the first time that the limitation of fault currents with D-FACTS devices is addressed. DSSC is one of the D-FACTS families whichoperate in a similar manner as Static Synchronous Series Compensator (SSSC) but in smaller size, lower price and more capability. The effectiveness of the DSSC in fault current limitation is investigated through the series voltage effect upon the line. The short circuit current limitation strategy presented here exhibited that besides of the power flow control which is carried out by DSSC; it can also perform this additional function. In the following the potency of the DSSC in reduction of instantaneous voltage dip range during fault current limiting mode is clarified. Furthermore, it is disclosed that with performing more DSSC in the power system, the entire system voltage dip will be improved. In order to validate the claims, computer simulations using PSCAD/EMTDC are exploited.


2013 ◽  
Vol 732-733 ◽  
pp. 782-788
Author(s):  
Jing Hao Chen ◽  
Wen Ying Liu ◽  
Wei Zheng ◽  
Chen Liang

A model for optimally evaluating grid short-circuit current limitation measures is proposed. Based on the fuzzy comprehensive evaluation model, a comprehensive evaluation system is introduced to consider the limiting effect and economy of the limiting measures configure program, also the program's impact on system security is involved. A judgment matrix is constructed to determine the weights of different system layers. With fuzzy behavior indices and membership function being led into, the evaluation of configuration program is given. Taking Gansu power grid for example, the feasibility and practicality of the proposed model are verified by simulation results.


Author(s):  
A. Yu. Kapustsinski ◽  
S. V. Kanstantsinava

The article discusses and systematizes the causes of high values of short-circuit currents in electrical networks up to 1 kV and indicates their negative consequences. A brief analysis of some current limiting methods (both with and without additional investment) is given, which makes it possible to reduce the negative effects when significant short-circuit currents occur. The variants of the implementation of these current limiting methods recommended for study at the design stage or when replacing equipment that has exhausted its resource, are considered. The advantages and disadvantages of the methods of limiting short-circuit currents described in the article are indicated. Options for connecting equipment with low power consumption to nodes of the electrical network up to 1 kV with high values of short-circuit currents are also considered. Special attention is paid to current-limiting protection devices, a detailed description of the design of some of them is given, the advantages of their use in comparison with other current-limiting methods are indicated, the corresponding graphs of the limitation of the periodic component of the short-circuit current, shock short-circuit current and thermal pulse are presented. Based on the analysis of graphic materials, the issue of ensuring the selectivity of protections is considered. The degree of prevalence of equipment with the property of current limitation is determined. A method for determining selective current-limiting protection devices is given, viz. the method of energy selectivity, the corresponding graphs for determining energy selectivity are presented. The physics allowing to determine the degree of efficiency of limiting the short-circuit current is described. Recommendations on the use of current-limiting equipment are proposed.


2010 ◽  
Vol 34-35 ◽  
pp. 1609-1613
Author(s):  
Yong Jian Li

Because of the extensive application of autotransformer in 500 kV power grid, the value of single-phase short-circuit current is generally greater than that of three-phase short-circuit current, or even greater than the maximum rated through current of the breaker. In order to reduce single-phase short-circuit current and avoid implement of bus split, this paper proposes to install small reactors on neutral points of 500 kV autotransformers. By analyzing and calculating the effect on short-circuit current limitation, the most suitable impedance value of small reactor is proposed. In addition,the overvoltage of the neutral point and insulation coordination are particularly discussed.