Online Predictive Modeling for the Thermal Effect of Implantable Devices

Author(s):  
Ruizhi Chai ◽  
Yen-Pang Lai ◽  
Wen Sun ◽  
Maysam Ghovanloo ◽  
Ying Zhang
Author(s):  
T. Sato ◽  
S. Kitamura ◽  
T. Sueyoshl ◽  
M. Iwatukl ◽  
C. Nielsen

Recently, the growth process and relaxation process of crystalline structures were studied by observing a SI nano-pyramid which was built on a Si surface with a UHV-STM. A UHV-STM (JEOL JSTM-4000×V) was used for studying a heated specimen, and the specimen was kept at high temperature during observation. In this study, the nano-fabrication technique utilizing the electromigration effect between the STM tip and the specimen was applied. We observed Si atoms migrated towords the tip on a high temperature Si surface.Clean surfaces of Si(lll)7×7 and Si(001)2×l were prepared In the UHV-STM at a temperature of approximately 600 °C. A Si nano-pyramid was built on the Si surface at a tunneling current of l0nA and a specimen bias voltage of approximately 0V in both polarities. During the formation of the pyramid, Images could not be observed because the tip was stopped on the sample. After the formation was completed, the pyramid Image was observed with the same tip. After Imaging was started again, the relaxation process of the pyramid started due to thermal effect.


2010 ◽  
Vol 6 (3) ◽  
pp. 87
Author(s):  
Niraj Varma ◽  

The use of implantable electronic cardiac devices is increasing. Post-implantation follow-up is important for monitoring both device function and patient condition; however, clinical practice is inconsistent. For example, implantable cardioverter–defibrillator follow-up schedules vary from every three months to yearly according to facility and physician preference and the availability of resources. Importantly, no surveillance occurs between follow-up visits. By contrast, implantable devices with automatic remote monitoring capability provide a means for performing constant surveillance, with the ability to identify salient problems rapidly. The Lumos-T Reduces Routine Office Device Follow-up Study (TRUST) demonstrated that remote home monitoring reduced clinic burden and allowed early detection of patient and/or system problems, enabling efficient monitoring and an opportunity to enhance patient safety. The results of the trial have significant implications for the management of patients receiving all forms of implantable electronic cardiac device.


Sign in / Sign up

Export Citation Format

Share Document