Considerations for Capacitance Measurements of Antenna Tuning RF Switches on Board

Author(s):  
Valentyn Solomko ◽  
Oguzhan Oezdamar ◽  
Danial Tayari ◽  
Matthias Voelkel ◽  
Simon Weiss ◽  
...  
Nanomaterials ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 820
Author(s):  
François Piquemal ◽  
José Morán-Meza ◽  
Alexandra Delvallée ◽  
Damien Richert ◽  
Khaled Kaja

Reference samples are commonly used for the calibration and quantification of nanoscale electrical measurements of capacitances and dielectric constants in scanning microwave microscopy (SMM) and similar techniques. However, the traceability of these calibration samples is not established. In this work, we present a detailed investigation of most possible error sources that affect the uncertainty of capacitance measurements on the reference calibration samples. We establish a comprehensive uncertainty budget leading to a combined uncertainty of 3% in relative value (uncertainty given at one standard deviation) for capacitances ranging from 0.2 fF to 10 fF. This uncertainty level can be achieved even with the use of unshielded probes. We show that the weights of uncertainty sources vary with the values and dimensions of measured capacitances. Our work offers improvements on the classical calibration methods known in SMM and suggests possible new designs of reference standards for capacitance and dielectric traceable measurements. Experimental measurements are supported by numerical calculations of capacitances to reveal further paths for even higher improvements.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Christoph Kandlbinder-Paret ◽  
Alice Fischerauer ◽  
Gerhard Fischerauer

Abstract In electrical capacitance tomography (ECT), the resolution of the reconstructed permittivity distribution improves with the number of electrodes used whereas the number of capacitance measurements and the measurement time increases with the number of electrodes. To cope with this tradeoff, we present a phantom-dependent adaptation scheme in which coarse measurements are performed with terminal electrodes interconnected to form a synthetic electrode ring with fewer but larger electrodes. The concept was tested by observing the sloshing of water inside a pipe. We compare the reconstructed results based on eight synthetic electrodes, on 16 elementary electrodes, and on the adaptation scheme involving both the eight synthetic electrodes and some of the elementary capacitances. The reconstruction used the projected Landweber algorithm for capacitances determined by a finite-element simulation and for measured capacitances. The results contain artefacts attributed to the influence of the high permittivity of water compared to the low permittivity of the pipe wall. The adaptation scheme leads to nearly the same information as a full measurement of all 120 elementary capacitances but only requires the measurement of 30 % fewer capacitances. By detecting the fill level using a tomometric method, it can be determined within an uncertainty of 5 % FS.


2014 ◽  
Vol 1634 ◽  
Author(s):  
Luana S. Araujo ◽  
Olivia Berengue ◽  
Maurício Baldan ◽  
Neidenei Ferreira ◽  
João Moro ◽  
...  

ABSTRACTDoped diamond films grown by chemical vapor techniques has been used to study hydrogen and oxygen terminated diamond. It is known that the electrical characteristics of metal-diamond interface are strongly affected by the diamond surface features. O2 plasma treatment was used as a cleaning procedure for as grown diamond samples leading to changes in the capacitance measurements after treatment. The alteration in the characteristics of the samples can be attributed to the surface adsorbates like hydrogen and water vapor present in the atmosphere. The results indicates that the O2 plasma treatment was effective in cleaning the surface revealing the expected features of a p-type diamond film.


Sign in / Sign up

Export Citation Format

Share Document