Compound synchronous reference frame PLL and unbalance control strategy for power conditioning system in weak grids

Author(s):  
Baoqi Liu ◽  
Shanxu Duan ◽  
Bangyin Liu ◽  
Changsong Chen ◽  
Xiaolong Jiang
2005 ◽  
Vol 20 (6) ◽  
pp. 1402-1412 ◽  
Author(s):  
R.I. Bojoi ◽  
G. Griva ◽  
V. Bostan ◽  
M. Guerriero ◽  
F. Farina ◽  
...  

PLoS ONE ◽  
2017 ◽  
Vol 12 (2) ◽  
pp. e0164856 ◽  
Author(s):  
Amirreza Naderipour ◽  
Abdullah Asuhaimi Mohd Zin ◽  
Mohd Hafiz Bin Habibuddin ◽  
Mohammad Reza Miveh ◽  
Josep M. Guerrero

2017 ◽  
Vol 863 ◽  
pp. 214-219
Author(s):  
Dan Li ◽  
Ting Ting Cai

This paper describes the use of an unbalanced control strategy to solve the faults occur in AC grid side of High voltage direct current based on Voltage Source Converter (VSC-HVDC) system. This method divides the voltage and current parameters into negative-sequence and positive-sequence. It can be obtained that the negative-sequence appears as double-frequency component in the positive-sequence synchronous reference frame; while, it appears as dc component in the negative-sequence synchronous reference frame. To mitigate the unfavourable impact of the unbalance fault, such as the DC link ripples, the dual vector control algorithm in dq synchrounous reference frame is designed. Simulation results demonstrate the validity and the effectiveness of the proposed control scheme.


Electronics ◽  
2018 ◽  
Vol 7 (10) ◽  
pp. 226 ◽  
Author(s):  
Jung-Yong Lee ◽  
Younghoon Cho

This paper proposes a synchronous reference frame (SRF) control strategy for a single-phase, three-level, dual-buck photovoltaic (PV) inverter. The concept of virtual d-q transformation is adapted to the current control of the inverter, and the repetitive controller is implemented in the SRF. With the proposed control strategy, the memory allocation quantity for the repetitive controller is decreased and the capability of the current reference tracking is maximized. Thus, the proposed method significantly reduces the total harmonic distortion (THD) of the output current in both the continuous conduction mode (CCM) and the discontinuous conduction mode (DCM). In addition, the distortion of the output current is mostly composed of odd harmonics. Odd harmonic expressed to the even harmonic in SRF can be calculated using Park’s transformation. Therefore, a repetitive controller can improve dynamics by considering only even harmonic components in SRF rather than including all harmonics. The simulation and the experimental results verify the effectiveness of the proposed control strategy. The proposed method not only reduces the THD of the output current in both the CCM operation and the DCM operation, but also improves the dynamics of the current controller.


2014 ◽  
Vol 716-717 ◽  
pp. 1648-1653
Author(s):  
Jia Jin Pan ◽  
Yan Cheng Liu ◽  
Chuan Wang ◽  
Qin Jin Zhang

Control strategy under unbalanced and distorted grid voltage is one of the most significant tasks for grid-connected inverter (GCI). In order to guarantee that the grid current meets the related IEEE Std.929-2000, a new control scheme was presented. Firstly, the typical model of GCI was presented. Secondly, the GCI control model based on PI-QR controller in synchronous reference frame (SRF) was built. Finally, the system’s simulation was conducted under distorted and unbalanced grid voltage. The results demonstrate the effectiveness of the presented control strategy.