Study of Three-phase Self-excited Induction Generator Operating as Single-phase Induction Generator Supplying Non-linear Load

Author(s):  
Panurak Nakorn ◽  
Parinya Machot ◽  
Vijit Kinnares ◽  
Chalermchat Manop
Author(s):  
R. A. Rani ◽  
Shakir Saat ◽  
Yusmarnita Yusop ◽  
Huzaimah Husin ◽  
F. K. Abdul Rahman ◽  
...  

This paper presents the effect of total harmonic distortion (THD) in power factor correction (PFC) at non-linear load. This study focuses on the relationship between THD and PFC. This is beacuse,the power factor affects THD. This occurs in power system as we have variety of loads, i. e linear load or non-linear load. The variety of loads will influence the sinusoidal waveform, which comes out from harmonic distortion. Thus, based on this study, we can compare the effective method in improving the power factor as it will not disturb the performance of THD. The focus of study is on the single phase load, where the voltage restriction is 240 V.  The analysis will  only focus on the consumer, which depends on the variety of non-linear load. Besides, the parameters for analysis are based on the percentage of THD and the value of power factor. The instrument for measuring the parameter is based on power factor correction device or technique. On the other hand, the method that was used for this study is based on simulation which incorporated the Multisim software. At the end of ths study, we can choose the most effective method that can be used to improve the power factor correction without disturbing the THD.


Author(s):  
M. A. Prishchepov ◽  
A. I. Zelenkevich ◽  
V. M. Zbrodyga

The problem of power quality supply is relevant for rural electrical networks, due to long distance and branching, as well as connection of a large number of single-phase and non-linear loads. Asymmetry of electrical loads causes voltage asymmetry, which adversely affects the operation of all elements of the electrical system, causing additional power losses, reducing the service life of electrical equipment and its economic performance, as well as reliability of operation of individual electrical equipment and power supply system as a whole. Reduction of voltage asymmetry can be ensured by rational construction of electrical network circuit and use of special correcting devices. The authors consider it reasonable to use relatively simple and reliable by design and inexpensive power transformers with a “star - double zigzag with a zero wire” (Y/2Zн) winding connection circuit with a neutral winding connection group. The paper deals with design and processes of converting electrical energy in a transformer. It has been proved that phase EMF of the secondary winding coincides in phase with the same EMF of the primary winding, i.e. the proposed circuit has a neutral windings’ connection group. Results of theoretical studies of transformer operation with an asymmetric and non-linear load are presented. Decrease in voltage asymmetry is due to the neutral sequence components compensation. Decrease of the higher harmonic voltage components level occurs due to the compensation of the higher harmonics multiplied three times. It is theoretically substantiated that transformer will not emit higher harmonic components of zero sequence voltages into the supply network. Experimental studies have confirmed the theoretical conclusions that a transformer with Y/2Zн winding connection circuit allows obtaining the highest level of voltage symmetry with an asymmetric load. In single-phase load mode, the values of voltage unbalance factor in reverse sequence do not exceed 1.7 %, in neutral sequence - 2.9 %. The transformer allows obtaining 1.2-1.5 times lower value of total harmonic components factor at non-linear load, which is the best result among circuits studied. This power transformer is resistant to load effects that distort voltage quality and is capable to provide a high level of symmetry and sinusoidal voltage as well as parallel operation with commercially available transformers. This makes it possible to use it in rural electrical networks to reduce power losses, increase service life and efficiency of electrical equipment, and increase reliability of the power supply system.


Author(s):  
Satyanarayan Gorantla ◽  
Goli Ravi Kumar

The paper presents the analysis of harmonic distortion when non-linear load is connected in different phases of power system with STATCOM for singly excited induction generator system with wind turbine as prime mover. Now-a-days due to the drastically increased in use of non linear loads causes many power quality problems in power system network. Those problems are classified as reactive power problems, harmonics, voltage sags and swells. Out of these problems harmonic problems are major concern. Custom power devices proposed for mitigation of power quality in network. For compensation of harmonic, static compensator (STATCOM) is used. The paper presents the compensation of harmonic power quality issues using STATCOM for the system with singly-excited induction generator feeding non-linear load connected in different phases. STATCOM is controlled using synchronous reference frame theory to produce pulses to switches of STATCOM sensing the input parameters. Proposed concept was developed using MATLAB/SIMULINK software and results are presented for non-linear load connected in different phases of the power system. THD analysis was shown for source current and load current for different cases.