Sizing and simulation of a low cost flywheel based energy storage system for wind diesel hybrid systems

Author(s):  
R. Sebastian ◽  
R. Pena-Alzola ◽  
J. Quesada ◽  
A. Colmenar
2021 ◽  
Author(s):  
Mervette El Batouti ◽  
H. A. Fetouh

New ferroelectric perovskite sample: excellent dielectric, negligible dielectric loss for energy storage systems such as solar cells, solar ponds, and thermal collectors has been prepared at low cost using nanotechnology.


Author(s):  
Xiang Long Huang ◽  
Yunxiao Wang ◽  
Shulei Chou ◽  
Shi Xue Dou ◽  
Zhiming M. Wang

Room-temperature sodium-sulfur (RT Na-S) batteries constitute an extremely competitive electrochemical energy storage system, owing to their abundant natural resources, low cost, and outstanding energy density, which could potentially overcome the...


Author(s):  
Songgang Qiu ◽  
Ross Galbraith ◽  
Maurice White

Thermal energy storage (TES) system integrated with concentrated solar power provides the benefits of extending power production, eliminating intermittency issues, and reducing system LOCE. Infinia Corporation is under the contract with DOE in developing TES systems. The goal for one of the DOE sponsored TES projects is to design and build a TES system and integrate it with a 3 KWe free-piston Stirling power generator. The Phase Change Material (PCM) employed for the designed TES system is a eutectic blend of NaF and NaCl which has a melt temperature of 680° C and energy storage capacity of 12 KWh. This PCM was selected due to its low cost and desired melting temperature. This melt temperature ensures the Stirling being operated at designed operating hot end temperature. The latent heat of this eutectic PCM offers 5 to 10 times the energy density of a typical molten salt. The technical challenges associated with low cost molten salt TES systems are the low thermal conductivity of the salt and large thermal expansion. To address these challenges, an array of sodium filled Heat Pipes (HP) is embedded in the PCM to enhance the heat transfer from solar receiver to PCM and from PCM to Stirling engine. The oversized dish provides sufficient thermal energy to operate a 3KWe Stirling engine at full power and to charge up the TES. The HP arrays are optimally distributed so that the solar energy is transferred directly from receiver to Stirling engine heat receiver. During the charge phase, the Stirling engine absorbs and converts the transferred solar energy to electricity and the excess thermal energy is re-directed and stored to PCM. The stored energy is transferred via distributed HP from PCM to Stirling engine heat receiver during discharge phase. The HP based PCM thermal energy storage system was designed, built, and performance tested in laboratory. The TES/engine assembly was tested in two different orientations representing the extremes of system operation when mounted on sun-tracking dish, horizontal and vertical. Horizontal represents the zero elevation at sun rise and the vertical represents the extreme of solar noon. The testing allows the examination of orientation effect on the heat pipe performance and the maximum charge and discharge rates. The total energy stored and extracted was also examined. The areas for further system refinements were identified and discussed.


Author(s):  
Yili Zhang ◽  
Sean Kissick ◽  
Hailei Wang

Abstract City’s electricity power grid is under heavy load during on-peak hours throughout summer cooling season. As the result, many utility companies implemented the time-of-use rate of electricity leading to high electricity cost for customers with significant cooling needs. On the other hand, the need for electricity and/or cooling decreases greatly at night, creating excess electricity capacity for further utilization. An innovative ice energy storage system is being developed leveraging a unique supercooling-based ice production process. During off-peak hours, the proposed system stores the low-cost electric energy in the form of ice; during on-peak hours, the system releases the stored energy to meet extensive home cooling needs. Thus, it can not only reduce energy and cost of cooling, but also increase the penetration of renewable energies (especially wind energy). In this paper, the working principles of the system is presented along with the modeling details of the overall system and several key components. The simulink model takes in hourly temperature and peak/off peak electricity cost data to dynamically simulate the amount of energy required and associated cost for cooling an average home. Both energy consumption and cost for homes using the cooling system with ice energy storage in two US cities have been compared with those using conventional HVAC cooling system. According to the model, huge reduction in energy cost (up to 3X) can be achieved over 6 months of cooling season in regions with high peak electricity rates. While only moderate reduction on energy consumption is predicted for the ice energy storage system, further energy reduction potentials have been identified for future study.


Author(s):  
Yili Zhang ◽  
Sean Kissick ◽  
Hailei Wang

Abstract City’s electricity power grid is under heavy load during on-peak hours throughout summer cooling season. As the result, many utility companies implemented the time-of-use rate of electricity leading to high electricity cost for customers with significant cooling needs. On the other hand, the need for electricity and/or cooling decreases greatly at night, creating excess electricity capacity for further utilization. An innovative ice energy storage system is being developed leveraging a unique supercooling-based ice production process. During off-peak hours the proposed system stores the low-cost electric energy in the form of ice; during on-peak hours the system releases the stored energy to meet extensive home cooling needs. Thus, it can not only reduce energy and cost of cooling, but also increase the penetration of renewable energies (especially wind energy). In this paper, the working principles of the system is presented along with the modeling details of the overall system and several key components. The Simulink model takes in hourly temperature and peak/off peak electricity cost data to dynamically simulate the amount of energy required and associated cost for cooling an average home. Both energy consumption and cost for homes using the cooling system with ice energy storage in two US cities have been compared with those using conventional HVAC cooling system. According to the model, huge reduction in energy cost (up to 3X) can be achieved over six months of cooling season in regions with high peak electricity rates. While only moderate reduction on energy consumption is predicted for the ice energy storage system, further energy reduction potentials have been identified for future study.


Author(s):  
Justin Andrew Lee ◽  
Christopher N. Salerno ◽  
Karen U. Girgis ◽  
Ulyses Aguirre ◽  
Reza Baghaei Lakeh

Abstract Inorganic salts (e.g., chloride salts) have gained attention in the energy field as a new thermal energy storage medium. Low cost, high melting temperature and high heat capacity of inorganic salts make them attractive in utility-scale thermal storage applications as higher energy storage temperatures lead to higher efficiency in power generation. There is a potential to use the dry byproduct of water desalination, i.e., Reverse Osmosis Concentrate (ROC) as a thermal storage medium. Using ROC as a thermal energy storage medium would prevent a harmful waste to be released to the environment while introducing a novel and low-cost alternative for thermal energy storage medium. In this study, heat transfer behavior of an ROC-based thermal energy storage system is studied using CFD. A computational model is developed, verified, and validated to simulate the phase change process and buoyancy-driven flow in a square ROC-based thermal energy storage element. The computational results provide a predictive model for charge and discharge cycles of an ROC-based thermal energy storage system.


Sign in / Sign up

Export Citation Format

Share Document