The Control System for Heating of Small Buildings with Heat Recovery unit and Heat Pump

Author(s):  
Jakub Jirinec ◽  
David Rot
2018 ◽  
Author(s):  
Takao Katsura ◽  
Yutaka Shoji ◽  
Yoshiki Miyashita ◽  
Katsunori Nagano ◽  
Yasushi Nakamura

2014 ◽  
Vol 535 ◽  
pp. 37-41
Author(s):  
Yang Li ◽  
Xiu Juan Liang

In the cold and severe cold regions of our country, the average temperature in winter outdoor usually below -20°C. Air conditioning units was limited and damaged when it running under such conditions. In order to solve the the problems pointed out previously, the paper put forward solutions of the fresh air handling units in combination with heat pump unit of heat recovery fresh air and heat pipe heat pump low temperature heat recovery unit. Comparison energy-saving and recovery period of the two method through experimental research.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2210
Author(s):  
Kofi Amoabeng ◽  
Jong Choi

Heat pumps are used in many applications, both in households and industries, for space air conditioning and hot water provision. The calorimeter is the equipment used in testing the heat pump system to obtain performance data. In the conventional testing mode and under standard conditions, the calorimeter utilizes a lot of energy through refrigeration and heating systems. In this study, a newly developed calorimeter with a heat recovery unit was used to test the performance of a water-to-water heat pump system. The aim was to minimize the rate of energy used in the conventional calorimeter. Two heat recovery control methods were adopted. In the control (1), the heat recovery unit was used to control the inlet water temperature setpoint for the heat pump indoor heat exchanger, whereas in control (2), the heat recovery unit was used to control the inlet water temperature setpoint for the heat pump outdoor heat exchanger. Tests were executed by varying the operating mode and test conditions. For the heating operating mode, the inlet water setpoint temperatures for the indoor and outdoor heat pump heat exchangers were 40 °C and 5 °C, respectively, whereas for the cooling mode, the inlet water setpoint temperatures for the outdoor and indoor heat pump heat exchangers were 25 °C and 12 °C, respectively. The analyses of the experimental results revealed that the energy saving of the calorimeter with heat recovery was about 71% in cooling mode and 73% in heating mode compared to the conventional calorimeter. Also, the energy consumption of the proposed calorimeter was analyzed based on the control methods. In heating mode, the calorimeter performance was enhanced when the control (2) strategy was used because the energy saving was about 8 to 13% compared to control (1). However, in the cooling mode test, it was the control (1) method that resulted in energy savings of about 6.4 to 21% compared to the control (2) method.


2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 137
Author(s):  
Florian Schlosser ◽  
Heinrich Wiebe ◽  
Timothy G. Walmsley ◽  
Martin J. Atkins ◽  
Michael R. W. Walmsley ◽  
...  

Heat pumps are the key technology to decarbonise thermal processes by upgrading industrial surplus heat using renewable electricity. Existing insight-based integration methods refer to the idealised Grand Composite Curve requiring the full exploitation of heat recovery potential but leave the question of how to deal with technical or economic limitations unanswered. In this work, a novel Heat Pump Bridge Analysis (HPBA) is introduced for practically targeting technical and economic heat pump potential by applying Coefficient of Performance curves into the Modified Energy Transfer Diagram (METD). Removing cross-Pinch violations and operating heat exchangers at minimum approach temperatures by combined application of Bridge Analysis increases the heat recovery rate and reduce the temperature lift to be pumped at the same time. The insight-based METD allows the individual matching of heat surpluses and deficits of individual streams with the capabilities and performance of different market-available heat pump concepts. For an illustrative example, the presented modifications based on HPBA increase the economically viable share of the technical heat pump potential from 61% to 79%.


2021 ◽  
Vol 123 ◽  
pp. 45-51
Author(s):  
Yun Zhang ◽  
Cichong Liu ◽  
Daxiong Lu ◽  
Zhenjun Guo ◽  
Dajian Wang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document