Random incoherent antenna arrays focused in the near field zone

Author(s):  
D. A. Vedenkin ◽  
A. R. Nasybullin ◽  
Y. E. Sedelnikov
Keyword(s):  
2013 ◽  
Vol 10 (1) ◽  
pp. 113-124
Author(s):  
Marija Milijic ◽  
Aleksandar Nesic ◽  
Bratislav Milovanovic

The paper defines the border between the far and near field zone of printed antenna arrays. The conventional definition has a limited application in side lobe suppression measurements, especially in the case of high side lobe suppression. The paper particularly details the printed antenna array with 8 radiation elements. Its symmetrical tapered feed network with Chebyshev distribution enables side lobe suppression greater than -44 dB in the E-plane. In addition, the influence of tolerances in the standard photolithographic process has been investigated. The expected tolerances in the standard photolithographic process have been assumed with moderate precision in order to estimate the side lobe suppression degradation due to amplitude and phase deviations, as well as deviations to optimized values in radiating element positioning.


Author(s):  
А.В. Ашихмин ◽  
И.Б. Крыжко ◽  
А.Б. Токарев ◽  
А.А. Фатеев

При создании корреляционно-фазовых пеленгаторов, как правило, в качестве антенных элементов используют ненаправленные антенные элементы (АЭ). Для использования измерений направленных АЭ требуется модифицировать алгоритмы пеленгации. Представлены соответствующие модификации алгоритмов и проведено сравнительное исследование точности пеленгования применительно к двухканальным корреляционно-интерферометрическим стандартным пеленгаторам, использующим плоские антенные решетки из направленных и ненаправленных АЭ. Рассмотрена также возможность определения пеленгов лишь по энергетическим измерениям, отсутствующая применительно к пеленгаторам с ненаправленными АЭ. Показано, что применение направленных АЭ позволяет снизить вероятность возникновения аномальных ошибок, повысить точность пеленгования при существенно больших значениях угла места, определяющего направление на источник радиоизлучения, снизить негативное влияние отказа от учета сферичности приходящей волны и, следовательно, уменьшить размеры ближней зоны пеленгатора, для которой характерно появление аномальных ошибок пеленгования. В многосигнальной радиообстановке использование направленных свойств АЭ позволяет также формировать пеленгационную диаграмму, обеспечивающую частичное подавление помеховых сигналов. Вместе с тем эффективное использование направленных свойств антенных АЭ требует максимально точного учета их диаграмм направленности (ДН). Погрешности описания ДН могут приводить к заметным ошибкам при определении пеленга, поэтому повышение качества работы пеленгационной системы за счет использования направленных АЭ сопровождается повышением требований к определению и точности практической реализации ДН АЭ When creating correlation-phase direction finders, as a rule, non-directional antenna elements (AE) are used. To use directional AE measurements, it is necessary to modify the direction finding algorithms. We present the corresponding modifications of the algorithms and we carried out a comparative study of the direction finding accuracy in relation to two-channel correlation-interferometric standard direction finders using flat antenna arrays of directional and non-directional AEs. We also considered the possibility of determining bearings only from energy measurements, which is absent in relation to direction finders with nondirectional AE. We show that the use of directional AEs makes it possible to reduce the probability of occurrence of anomalous errors, to increase the accuracy of direction finding at significantly large values of the elevation angle, which determines the direction to the radio emission source, to reduce the negative effect of refusing to take into account the sphericity of the incoming wave and, consequently, to reduce the size of the near-field zone of a bearer, which is characterized by the appearance of abnormal direction finding errors. In a multi-signal radio environment, the use of the directional properties of the AE also makes it possible to form a direction finding diagram that provides partial suppression of interference signals. At the same time, the effective use of the directional properties of antenna AEs requires the most accurate consideration of their directional patterns (DP). Errors in the description of the pattern can lead to noticeable errors in determining the bearing, therefore, improving the quality of operation of the direction finding system due to the use of directional AEs is accompanied by increased requirements for the determination and accuracy of practical implementation of the pattern of AE


2000 ◽  
Vol 88 (5) ◽  
pp. 2541-2547 ◽  
Author(s):  
N. Richard ◽  
A. Dereux ◽  
E. Bourillot ◽  
T. David ◽  
J. P. Goudonnet ◽  
...  

2003 ◽  
Vol 25 (2) ◽  
pp. 122-133 ◽  
Author(s):  
Robert Ferrière ◽  
Serge Mensah ◽  
Jean-Pierre Lefebvre

Our objective is to develop an ultrasonic scanner for breast imaging. High resolution is obtained by using wide-band spherical waves transmitted and measured in the near field zone (i.e., close to the skin) all around the organ. The tomographic approach that we adopt allows us to use low central frequency waves (3–7 MHz) that are suitable for good penetration while maintaining high resolution and contrast. The procedure is thus suitable for early detection of tumors and increases the chances of total recovery. The novelty of the present reconstruction procedure is that it associates the signals acquired in transmission to the data measured in reflection over a large aperture. This enables us to correct the phase aberration induced by weak inhomogeneities whose sizes might be several wavelengths. Numerical tests based on Finite Difference Time Domain (FDTD) simulations demonstrate the greater fidelity of the reconstruction.


Sign in / Sign up

Export Citation Format

Share Document