A current control strategy of three-phase grid-connected inverter with LCL filter based on one-cycle control

Author(s):  
Xiao-dong Liu ◽  
Jing Wu ◽  
Su-cheng Liu ◽  
Wei Fang ◽  
Yan-fei Liu
2017 ◽  
Vol 32 (7) ◽  
pp. 5023-5034 ◽  
Author(s):  
Xing Zhang ◽  
Peng Chen ◽  
Changzhou Yu ◽  
Fei Li ◽  
Hieu Thanh Do ◽  
...  

2021 ◽  
Vol 11 (7) ◽  
pp. 3170
Author(s):  
Yahui Li ◽  
Jing Zhang ◽  
Zhenghang Hao ◽  
Peng Tian

Aiming at the problem of power coupling and complicated decoupling in the d-q coordinate system of a three-phase grid-connected inverter, a current closed-loop control strategy based on an improved QPIR (quasi-proportional integral resonant) controller in the α-β two-phase static coordinate system is proposed. Firstly, the mathematical model of an LCL three-phase grid-connected inverter is established, and its instantaneous power calculation equation is deduced. Secondly, the frequency method is applied to compare and analyze the proportional resonant, quasi-proportional resonant, and improved current controller, and the appropriate improved controller parameters are obtained according to the traditional proportional integral controller parameter design method and the weight coefficient. Finally, the improved controller is compared with the traditional controller in the simulation model of the LCL three-phase grid-connected inverter based on active damping. The results show that the proposed improved current control strategy has good dynamic response characteristics, can realize the non-static error control of grid-connected current, and realizes the decoupling control of active power and reactive power when the load jumps. At the same time, the results also prove the superiority of the proposed control strategy and verify its effectiveness.


2012 ◽  
Vol 614-615 ◽  
pp. 1578-1582
Author(s):  
Chun Qing Qi ◽  
Yi Ruan ◽  
Feng Wen Cao

This paper proposes a control strategy,based on the grid voltage oriented vector control (VOC), which makes three-phase inverter control the active and reactive power of grid-connected inverter under the premise of the direct current control. This paper analyzes the principle of three phase photovoltaic grid connected inverter and describes the control structure of the inverter. The control strategy can overcome the deficiencies of the indirect current control scheme. This paper designs the current closed-loop control system, which not only improve the system dynamic response speed and output current waveform quality, while also reduce its sensitivity to parameter changes to improve the robustness of the system. The simulation results show the validity of control strategy proposed.


2011 ◽  
Vol 347-353 ◽  
pp. 591-600
Author(s):  
Nguyen Viet Ngu ◽  
Hong Hua Wang ◽  
Le Thi Minh Tam

The control objective of three-phase photovoltaic (PV) grid-connected inverter is to generate high quality and stable AC sinusoidal output power with the same phase angle, frequency and amplitude compatible with the grid-connected voltage. To overcome the shortcoming of the normal current PWM control method and traditional PI algorithm, this paper researches a combined control strategy of three phase PV grid-connected inverter based on fuzzy PI controller. The combined control strategy switches different PWM current control method among the hysteretic PWM, SVPWM, hysteretic current SVPWM according to the error between command current and feedback current,and the d-axis command current is output of fuzzy PI controller of DC bus voltage. The simulation model of the combined control strategy for three phase PV grid-connected inverter based on normal PI controller is built with Matlab, simulation results verified the combination control strategy based on fuzzy PI controller has excellent performances.


Sign in / Sign up

Export Citation Format

Share Document