Test Comparison Study on a Natural Ester Retro-filled 220kV Power Transformer

Author(s):  
Zhiqiang Huang ◽  
Ruifeng Wang ◽  
Kevin James Rapp ◽  
Gang Liu
Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1510
Author(s):  
Raymon Antony Raj ◽  
Ravi Samikannu ◽  
Abid Yahya ◽  
Modisa Mosalaosi

Increasing usage of petroleum-based insulating oils in electrical apparatus has led to increase in pollution and, at the same time, the oils adversely affect the life of electrical apparatus. This increases the demand of Mineral Oil (MO), which is on the verge of extinction and leads to conducting tests on natural esters. This work discusses dielectric endurance of Marula Oil (MRO), a natural ester modified using Conductive Nano Particle (CNP) to replace petroleum-based dielectric oils for power transformer applications. The Al2O3 is a CNP that has a melting point of 2072 °C and a low charge relaxation time that allows time to quench free electrons during electrical discharge. Al2O3 is blended with the MRO and Mineral Oil (MO) in different concentrations. The measured dielectric properties are transformed into mathematical equations using the Lagrange interpolation polynomial functions and compared with the predicted values either using Gaussian or Fourier distribution functions. Addition of Al2O3 indicates that 0.75 g/L in MRO has an 80% survival rate and 20% hazard rate compared to MO which has 50% survival rate and 50% hazard rate. Considering the measured or interpolated values and the predicted values, they are used to identify the MRO and MO’s optimum concentration produces better results. The test result confirms the enhancement of the breakdown voltage up to 64%, kinematic viscosity is lowered by up to 40% at 110 °C, and flash/fire points of MRO after Al2O3 treatment enhanced to 14% and 23%. Hence the endurance of Al2O3 in MRO proves to be effective against electrical, physical and thermal stress.


Author(s):  
Bokang Agripa Tlhabologo ◽  
Ravi Samikannu ◽  
Modisa Mosalaosi

Transformer liquid dielectrics evolved where mineral oil has been the dominant choice until emergence of synthetic esters and natural esters. Natural ester-based oils have been under extensive investigations to enhance their properties for replacing petroleum-based mineral oil, which is non-biodegradable and has poor dielectric properties. This paper focuses on exposition of natural ester oil application in mixed transformer liquid dielectrics. Physical, chemical, electrical, and ageing characteristics of these dielectrics and the dissolved gas analysis (DGA) were reviewed. Physical properties include viscosity, pour point, flash and fire point which are vital indicators of heat insulation and fire risk. Chemical properties considered are water content, acid number, DGA, corrosive sulphur, and sludge content to limit and detect degradation and corrosion due to oil ageing. Electrical properties including breakdown voltage were considered for consistent insulation during overload and fault conditions. These properties of evolving alternative dielectrics were reviewed based on ASTM International standards and International Electro technical Commission standards for acceptable transformer liquid dielectrics. This review paper was compiled to avail modern methodologies for both the industry and scholars, also providing the significance of using mixed dielectrics for power transformers as they are concluded to show superiority over non-mixed dielectrics.


2016 ◽  
Vol 23 (1) ◽  
pp. 246-257 ◽  
Author(s):  
Kapila Bandara ◽  
Chandima Ekanayake ◽  
Tapan Kumar Saha ◽  
Pratheep Kumar Annamalai

2017 ◽  
Vol 202 ◽  
pp. 168-175 ◽  
Author(s):  
Jian Hao ◽  
Min Dan ◽  
Yanqing Li ◽  
Ruijin Liao ◽  
George Chen

2013 ◽  
pp. 1158-1163 ◽  
Author(s):  
Fernando Delgado ◽  
Inmaculada Fernández ◽  
Domingo Urquiza ◽  
Bekir Mumyakmaz ◽  
Abdurrahman Unsal

Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 490
Author(s):  
Dominika Szcześniak ◽  
Piotr Przybylek

Increasing environmental demands influence the requirements for devices and materials used in the power industry. One example is a power transformer and an electro-insulating liquid used in it. In order to meet these requirements, electro-insulating liquids should be characterized by, inter alia, high biodegradability and good fire properties. One of such liquids is natural ester. However, its oxidation stability is low in comparison to mineral oil and demands improvement, which can be achieved by the addition of an antioxidant. The authors of this work used fullerene nanoparticles for that purpose. Pure natural ester samples were prepared, and samples with two concentrations of fullerene, 250 mg/L and 500 mg/L in natural ester. All these samples were aged in a thermal oxidation process. Thereafter, the aging properties of all the samples were compared to assess the oxidation stability of modified liquids. Moreover, the electrical properties of prepared insulating liquids were investigated to assess if fullerene deteriorates these properties after aging process. Based on the obtained results, it was proved that the aging process slowed down in the case of both fullerene concentrations in ester. The acid number of natural ester modified using fullerene was lower than in the case of pure liquid.


Sign in / Sign up

Export Citation Format

Share Document