Chopping off peak demand using DLS technique — Formulating an intelligent technique for load identification

Author(s):  
Arindam Kumar Sil ◽  
N. K. Deb ◽  
Ashok Kumar Maitra ◽  
Poly Sil Sen
2015 ◽  
Vol 135 (1) ◽  
pp. 71-77
Author(s):  
Takayuki Sugimoto ◽  
Eisuke Shimoda ◽  
Toshihiro Yamane ◽  
Shigeo Numata

2021 ◽  
pp. 127891
Author(s):  
Miguel A. Peinado-Guerrero ◽  
Jesus R. Villalobos ◽  
Patrick E. Phelan ◽  
Nicolas A. Campbell

2021 ◽  
Vol 1838 (1) ◽  
pp. 012071
Author(s):  
Zhongxiang Wang ◽  
Ning Zhu ◽  
Yi Yin ◽  
Maosheng He ◽  
Qiang Zhang
Keyword(s):  

Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2917
Author(s):  
Mohammad Dabbagh ◽  
Moncef Krarti

This paper evaluates the potential energy use and peak demand savings associated with optimal controls of switchable transparent insulation systems (STIS) applied to smart windows for US residential buildings. The optimal controls are developed based on Genetic Algorithm (GA) to identify the automatic settings of the dynamic shades. First, switchable insulation systems and their operation mechanisms are briefly described when combined with smart windows. Then, the GA-based optimization approach is outlined to operate switchable insulation systems applied to windows for a prototypical US residential building. The optimized controls are implemented to reduce heating and cooling energy end-uses for a house located four US locations, during three representative days of swing, summer, and winter seasons. The performance of optimal controller is compared to that obtained using simplified rule-based control sets to operate the dynamic insulation systems. The analysis results indicate that optimized controls of STISs can save up to 81.8% in daily thermal loads compared to the simplified rule-set especially when dwellings are located in hot climates such as that of Phoenix, AZ. Moreover, optimally controlled STISs can reduce electrical peak demand by up to 49.8% compared to the simplified rule-set, indicating significant energy efficiency and demand response potentials of the SIS technology when applied to US residential buildings.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1195
Author(s):  
Ali Saberi Derakhtenjani ◽  
Andreas K. Athienitis

This paper presents control strategies to activate energy flexibility for zones with radiant heating systems in response to changes in electricity prices. The focus is on zones with radiant floor heating systems for which the hydronic pipes are located deep in the concrete and, therefore, there is a significant thermal lag. A perimeter zone test-room equipped with a hydronic radiant floor system in an environmental chamber is used as a case study. A low order thermal network model for the perimeter zone, validated with experimental measurements, is utilized to study various control strategies in response to changes in the electrical grid price signal, including short term (nearly reactive) changes of the order of 10–15 min notice. An index is utilized to quantify the building energy flexibility with the focus on peak demand reduction for specific periods of time when the electricity prices are higher than usual. It is shown that the developed control strategies can aid greatly in enhancing the zone energy flexibility and minimizing the cost of electricity and up to 100% reduction in peak power demand and energy consumption is attained during the high-price and peak-demand periods, while maintaining acceptable comfort conditions.


Sign in / Sign up

Export Citation Format

Share Document