Robust Repetitive Controller Design Based on S/SK Problem for Single-phase Grid-connected Inverters

Author(s):  
Yifei Sun ◽  
Qiangsong Zhao ◽  
Wudai Liao ◽  
Kailong Jiang ◽  
Wenxin Tan
Author(s):  
J. Fulna Kanaga ◽  
◽  
P. Subha Hency Jose ◽  

2011 ◽  
Vol 13 (6) ◽  
pp. 1051-1055 ◽  
Author(s):  
Wentao Chen ◽  
Yechun Lin

2020 ◽  
Author(s):  
Bowen Dou ◽  
Rufei He ◽  
Zhiqiang Wang ◽  
Qing Li ◽  
Chuangjia Chen ◽  
...  

Energies ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 131 ◽  
Author(s):  
Jinwoo Kim ◽  
Sanghun Han ◽  
Wontae Cho ◽  
Younghoon Cho ◽  
Hyunsoo Koh

This paper studies a repetitive controller design scheme for a bridgeless single-ended primary inductor converter (SEPIC) power factor correction (PFC) converter to mitigate input current distortions. A small signal modeling of the converter is performed by a fifth-order model. Since the fifth-order model is complex to be applied in designing a current controller, the model is approximated to a third-order model. Using the third-order model, the repetitive controller is designed to reduce the input current distortion. Then, the stability of the repetitive controller is verified with an error transfer function. The proposed controller performance is validated by simulation, and the experiment results show that the input current total harmonic distortion (THD) is improved by applying the proposed controller for an 800 W bridgeless SEPIC PFC converter prototype.


2013 ◽  
Vol 860-863 ◽  
pp. 2351-2355
Author(s):  
Jie Zhang ◽  
Hong Wei Ma

A PRE control scheme in single-phase inverter is adopted, namely connecting the proportional component with repetitive controller in parallel. This control scheme not only retains the characteristics of fast dynamic response from proportion link ,but also absorbs the advantages of no steady-state error in repetitive control .When the system is in stable operation condition, repetitive controller is used to resist periodic disturbance and thus improve the steady-state performance. Contrarily, the proportional component can feel mutation of input error and produce accommodation immediately to ensure the systems fast speed of response .The comprehensive theoretical analysis of this control strategy is given, and the system is designed in Matlab based on this theory, besides, the control scheme is achieved in the DSP platform by using digital control algorithm. Simulation and experimental results prove that the proposed scheme can achieve good dynamic and steady-state performance.


Sign in / Sign up

Export Citation Format

Share Document