Automatic mode matching control loop design and its application to the mode matched MEMS gyroscope

Author(s):  
Byung Su Chang ◽  
Woon-Tahk Sung ◽  
Jang Gyu Lee ◽  
Kang-Yoon Lee ◽  
Sangkyung Sung
Micromachines ◽  
2020 ◽  
Vol 11 (2) ◽  
pp. 210
Author(s):  
Zhihu Ruan ◽  
Xukai Ding ◽  
Zhengcheng Qin ◽  
Jia Jia ◽  
Hongsheng Li

An automatic mode-matching method for MEMS (Micro-electromechanical Systems) disk resonator gyroscopes (DRGs) based on virtual Coriolis force is presented in this paper. For this mode-matching method, the additional tuning electrodes are not required to be designed, which simplifies the structure design. By using the quadratic relationship between the driving voltage and the electrostatic force, the virtual Coriolis force is obtained by applying an AC voltage whose frequency is half of the driving mode resonant frequency to the sense electrode. The phase difference between the virtual Coriolis force and the sense output signal is used for mode-matching. The structural characteristics and electrode distribution of the DRG are briefly introduced. Moreover, the mode-matching theories of the DRG are studied in detail. The scheme of the mode-matching control system is proposed. Simultaneously, the feasibility and effectiveness of the mode-matching method are verified by system simulation. The experimental results show that under the control of mode-matching at room temperature, the bias instability is reduced from 30.7575 ° /h to 2.8331 ° /h, and the Angle Random Walk (ARW) decreases from 1.0208 ° / h to 0.0524 ° / h . Compared with the mode mismatch condition, the ARW is improved by 19.48 times.


Micromachines ◽  
2019 ◽  
Vol 10 (8) ◽  
pp. 496
Author(s):  
Cheng Li ◽  
Bo Yang ◽  
Xin Guo ◽  
Lei Wu

A digital excitation-calibration technique of dual-mass MEMS gyroscope for closed-loop mode-matching control is presented in this paper. The technique, which takes advantage of the symmetrical amplitude response of MEMS gyroscope, exploits a two-side excitation signal to actuate the sense mode to obtain the corresponding DC tuning voltage. The structural characteristics of dual-mass decoupled MEMS gyroscope and the tuning principle of excitation-calibration technique are introduced firstly. Then, the scheme of digital excitation-calibration system for the real-time mode-matching control is presented. Simultaneously, open-loop analysis and closed-loop analysis are deduced, respectively, to analyze the sources of tuning error and system stability. To verify the validity of the scheme and theoretical analysis, the system model was established by SIMULINK. The simulation results are proved to be consistent with the theoretical analysis, verifying the feasibility of the digital excitation-calibration technique. The control algorithms of the system were implemented with a FPGA device. Experimental results demonstrate that digital excitation-calibration technique can realize mode-matching within 1 s. The prototype with real-time mode-matching control has a bias instability of 0.813 ∘ /h and an ARW (Angular Random Walk) of 0.0117 ∘ / h . Compared to the mode-mismatching condition, the bias instability and ARW are improved by 3.25 and 4.49 times respectively.


2018 ◽  
Vol 4 (1) ◽  
pp. 99-107 ◽  
Author(s):  
Jiangheng Lu ◽  
Ayan Mallik ◽  
Shenli Zou ◽  
Alireza Khaligh
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document