Complex state-space current controller for grid-connected converters with an LCL filter

Author(s):  
Carlos Ramos ◽  
Antonio Martins ◽  
Adriano Carvalho
2018 ◽  
Vol 33 (5) ◽  
pp. 3765-3778 ◽  
Author(s):  
Diego Perez-Estevez ◽  
Jesus Doval-Gandoy ◽  
Alejandro G. Yepes ◽  
Oscar Lopez ◽  
Fernando Baneira

2021 ◽  
Author(s):  
EVERSON MATTOS ◽  
LUCAS CIELO BORIN ◽  
CAIO RUVIARO DANTAS OSóRIO ◽  
GUSTAVO GUILHERME KOCH ◽  
VINíCIUS FOLETTO MONTAGNER

This paper provides a two step procedure for current control design of grid-connected converters with LCL filter. The proposed procedure is based on: i) an internal loop with state feedback, aiming on active damping of the LCL filter resonance; ii) an external loop with resonant controllers, aiming to ensure tracking of sinusoidal grid current references. The state feedback gains are computed based on pole location and the resonant control gains are computed based on the minimization of a closedloop tracking error index. A case study is shown to illustrate that the proposed control design procedure leads to grid-injected currents with suitable steady state and transient performances.


2018 ◽  
Vol 54 (5) ◽  
pp. 4537-4553 ◽  
Author(s):  
Diego Perez-Estevez ◽  
Jesus Doval-Gandoy ◽  
Alejandro G. Yepes ◽  
Oscar Lopez ◽  
Fernando Baneira

2021 ◽  
Vol 3 (3) ◽  
Author(s):  
Ayaz Ahmad ◽  
L. Rajaji ◽  
A. Iqbal

AbstractDistributed generators are playing a vital role in supporting the grid in ever-increasing energy demands. Grid code regulation must be followed when integrating the photovoltaic inverter system to the grid. The paper investigates and analyzes a controller model for grid-connected PV inverters to inject sinusoidal current to the grid with minimum distortion. To achieve better tracking and disturbance rejection, a DSP-based current controller is designed with LCL filter. The controller gets the current feedback from the grid, compares it with reference current, and calculates duty cycle to generate PWM pulses to trigger H-bridge converters. The grid voltage is loaded to the initial value in proposed PR controller to ensure the initial inverter voltage to match the grid voltage. The paper presents a novel current controller algorithm for grid-connected inverter system, and simulation is done. A detailed analysis has been carried out to validate the proposed design algorithm. Experimental implementation of the current controller in the DC/AC converter circuits with an LCL filter is done for 5.4 kW to validate and match the simulation model.