grid connected converters
Recently Published Documents


TOTAL DOCUMENTS

370
(FIVE YEARS 132)

H-INDEX

32
(FIVE YEARS 7)

Author(s):  
Issam A. Smadi ◽  
Bayan H. Bany Fawaz

AbstractFast and accurate monitoring of the phase, amplitude, and frequency of the grid voltage is essential for single-phase grid-connected converters. The presence of DC offset in the grid voltage is detrimental to not only grid synchronization but also the closed-loop stability of the grid-connected converters. In this paper, a new synchronization method to mitigate the effect of DC offset is presented using arbitrarily delayed signal cancelation (ADSC) in a second-order generalized integrator (SOGI) phase-locked loop (PLL). A frequency-fixed SOGI-based PLL (FFSOGI-PLL) is adopted to ensure better stability and to reduce the complexity compared with other SOGI-based PLLs. A small-signal model of the proposed PLL is derived for the systematic design of proportional-integral (PI) controller gains. The effects of frequency variation and ADSC on the proposed PLL are considered, and correction methods are adopted to accurately estimate grid information. The simulation results are presented, along with comparisons to other single-phase PLLs in terms of settling time, peak frequency, and phase error to validate the proposed PLL. The dynamic performance of the proposed PLL is also experimentally validated. Overall, the proposed PLL has the fastest transient response and better dynamic performance than the other PLLs for almost all performance indices, offering an improved solution for precise grid synchronization in single-phase applications.


2021 ◽  
Author(s):  
Alon Kuperman

<p>It is well-known that attainable DC link voltage loop bandwidth in grid-connected converters operating with unity power factor is limited due to trade-off with AC-side current total harmonic distortion (THD). The letter reveals that THD requirement directly imposes the value of voltage loop gain magnitude at double-grid frequency; therefore the dynamic performance may be improved without deteriorating the grid-side current quality by modifying the controller structure such that the loop gain magnitude at double-grid frequency and the crossover frequency are decoupled. Experimental results validate the revealed findings.</p>


2021 ◽  
Author(s):  
Alon Kuperman

<p>It is well-known that attainable DC link voltage loop bandwidth in grid-connected converters operating with unity power factor is limited due to trade-off with AC-side current total harmonic distortion (THD). The letter reveals that THD requirement directly imposes the value of voltage loop gain magnitude at double-grid frequency; therefore the dynamic performance may be improved without deteriorating the grid-side current quality by modifying the controller structure such that the loop gain magnitude at double-grid frequency and the crossover frequency are decoupled. Experimental results validate the revealed findings.</p>


2021 ◽  
Vol 42 (2) ◽  
pp. 227
Author(s):  
Arthur de Abreu Romão ◽  
Newton Da Silva

Distributed generation systems, based on renewable energy sources, are typically connected to the main grid by a voltage-source inverter with a low-pass filter. The need for improved efficiency led to the use of third order low-pass filters, such as the LCL configuration, which has resonant behavior. In order to meet energy quality requirements and ensure the systems stability it is necessary to suppress the LCL filters resonance through damping techniques. Therefore, this paper presents an overview of some damping strategies found in literature and its design procedure, applied to a simulated single-phase grid-tied inverter. The comparison of each presented damping methodology characteristics is described, with analysis of advantages and drawbacks for each case.


2021 ◽  
Vol 26 (04) ◽  
pp. 1-10
Author(s):  
Pedro C. Bolsi ◽  
Edemar O. Prado ◽  
Arthur F. Precht ◽  
João Manoel Lenz ◽  
Hamiltom Confortin Sartori ◽  
...  