Prediction for Magnitude of Short Circuit Current in Power Distribution System Based on ANN

Author(s):  
Chen Li-an
Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 334
Author(s):  
Esteban Pulido ◽  
Luis Morán ◽  
Felipe Villarroel ◽  
José Silva

In this paper, a new concept of short-circuit current (SCC) reduction for power distribution systems is presented and analyzed. Conventional fault current limiters (FCLs) are connected in series with a circuit breaker (CB) that is required to limit the short-circuit current. Instead, the proposed scheme consisted of the parallel connection of a current-controlled power converter to the same bus intended to reduce the amplitude of the short-circuit current. This power converter was controlled to absorb a percentage of the short-circuit current from the bus to reduce the amplitude of the short-circuit current. The proposed active short-circuit current reduction scheme was implemented with a cascaded H-bridge power converter and tested by simulation in a 13.2 kV industrial power distribution system for three-phase faults, showing the effectiveness of the short-circuit current attenuation in reducing the maximum current requirement in all circuit breakers connected to the same bus. The paper also presents the design characteristics of the power converter and its associated control scheme.


2012 ◽  
Vol 614-615 ◽  
pp. 916-920
Author(s):  
Xue Ling Zhu ◽  
Fei Han ◽  
Jia Liu

Technology of Micro-grid emerges, and power distribution system faults, allowing for the distributed generation keeping alive the islanded operation with the important load . But if the interior of Micro-grid happens a fault again, the short-circuit current of Micro-grid is so insufficient that traditional current protection can not play a part in the protection. In order to solve this problem, it introduced a new relay protection strategy, and provided the basis for the relay protection design of Micro-grid in the future.


Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 199
Author(s):  
Chengwei Lei ◽  
Weisong Tian

Fused contactors and thermal magnetic circuit breakers are commonly applied protective devices in power distribution systems to protect the circuits when short-circuit faults occur. A power distribution system may contain various makes and models of protective devices, as a result, customizable simulation models for protective devices are demanded to effectively conduct system-level reliable analyses. To build the models, thermal energy-based data analysis methodologies are first applied to the protective devices’ physical properties, based on the manufacturer’s time/current data sheet. The models are further enhanced by integrating probability tools to simulate uncertainties in real-world application facts, for example, fortuity, variance, and failure rate. The customizable models are expected to aid the system-level reliability analysis, especially for the microgrid power systems.


Author(s):  
Dung Vo Tien ◽  
Radomir Gono ◽  
Zbigniew Leonowicz

Power quality is a major concern in electrical power systems. The power quality disturbances such as sags, swells, harmonic distortion and other interruptions have impact on the electrical devices and machines and in severe cases can cause serious damages. Therefore it is required to recognize and compensate all types of disturbances at an earliest to ensure normal and efficient operation of the power system. To solve these problems, many types of power devices are used. At the present time, one of those devices, Dynamic Voltage Restorer (DVR) is the most efficient and effective device used in power distribution system. In this paper, design and modeling of a new structure of multifunctional DVR for voltage correction is presented. The performance of the device under different conditions such as voltage swell, voltage sag due to symmetrical and unsymmetrical short circuit, starting of motors, and voltage distortion are described. Simulation result shows the superior capability of proposed DVR to improve power quality under different operating conditions. The proposed new DVR controller is able to detect the voltage disturbances and control the converter to inject appropriate voltages independently for each phase and compensate to load voltage through three single- phase transformers.


2019 ◽  
Vol 8 (4) ◽  
pp. 6256-6261

Nowadays, there are various signal processing methods that have been studied by many researchers in order to detect faults in power lines. From previous literature, signal processing that works based on time frequency analysis has been proven to accurately detect faults at high speed. In this study, wavelet transform is adopted to analyse fault occurrences on power line of distribution network. Three types of faults due to lightning, switching and short circuit fault were analysed based on their voltage waveform profiles. ‘Daubechies’ 4 (db4) mother wavelet and four levels decomposition were implemented to extract the features. Approximation at level 4 (A4) and detail coefficient at level 1 to 4 (D1-D4) were extracted to evaluate the energy, skewness, and kurtosis. Based on the results, lightning showed the highest energy, skewness and kurtosis compared to the short circuit and switching voltage waveform. Therefore, these features can be utilized as the new parameters for fault detection in a power system network


2021 ◽  
Vol 6 (2) ◽  
pp. 1422
Author(s):  
Doni Abdul Mukti ◽  
Budi Sudiarto

Protection is a safety in the electric power system installed in the electric power distribution system, power transformer, electric power transmission, and electric generator used to secure the power system electricity from electrical disturbances or overloads by separating the disturbed parts of the electric power system from the undisturbed electrical power system so that the undisturbed electrical system can continue to work. The protection system at the T75B substation has a work failure where when there is a short circuit on the consumer side, it causes the PMT (Power Breaker) for the Malibu Feeder at the Kebon Sirih Substation to trip while the CBO (Circuit Breaker Outgoing) cubicle at the T75B substation does not trip. This resulted in an unexpected widespread blackout. To find out the cause of the failure of the protection system, several tests and analyzes were carried out, namely protection design testing, protection relay coordination testing, protection system construction analysis, protection equipment performance testing. It is hoped that the test results can be used as a reference for improvement so that similar failures do not recur.


1997 ◽  
Vol 3 (6) ◽  
pp. 52-59 ◽  
Author(s):  
R. Natarajan ◽  
T.A. Kneschke ◽  
W. Naqvi ◽  
M.A. Lopez-Lopez ◽  
J. Hong ◽  
...  

2017 ◽  
Vol 16 (2) ◽  
pp. 37
Author(s):  
I Dewa Gde Agung Budhi Udiana ◽  
I G Dyana Arjana ◽  
Tjok Gede Indra Partha

Short circuit causing over current problem and can might causing interference of the equipment performance such as distribution transformers also causing widespread disruption occurred. In resolving such interference is required as protection system on the distribution system. Seeing all above is needed coordination between the supporting component of the protection system which is consisted of Over Current Relay (OCR) and Ground Fault Relay (GFR). The research was conducted at PT. PLN (Persero) South Bali Area Network, INDONESIA on recloser in the feeder line of Penebel. OCR setting between the Relay feeder of Penebel, Recloser Celagi, Recloser Bakisan, and Recloser Benana still less selective, with time value coordination between average security was still less than 0,2 second. Then OCR setting and GFR relay feeder of Penebel, Recloser Celagi, Recloser Bakisan, and Recloser Benana was recommended for re-setting in order to minimize disruption and electric power distribution system to be reliable.


Author(s):  
K. V. Siva Reddy ◽  
SK. Moulali ◽  
K. Harinadha Reddy ◽  
Ch. Rami Reddy ◽  
B. V. RajannaRajanna ◽  
...  

In this paper, a micro grid resonance propagation model is investigated. To actively mitigate the resonance using DG units, an enhanced DG unit control scheme that uses the concept of virtual impedance is proposed. It can be seen that a conventional voltage-controlled DG unit with an LC filter has a short-circuit feature at the chosen harmonic frequencies, whereas a current-controlled DG unit presents an open-circuit characteristic. The application of underground cables and shunt capacitor banks may introduce power distribution system resonances. This paper additionally focuses on developing a voltage-controlled DG unit-based active harmonic damping technique for grid-connected and islanding micro grid systems. An improved virtual impedance control method with a virtual damping resistor and a nonlinear virtual capacitor is proposed. The nonlinear virtual capacitor is used to compensate the harmonic dip on the grid-side inductor of a DG unit LCL filter. The virtual resistance is principally answerable for micro grid resonance damping. The effectiveness of the proposed damping method is examined using each a single DG unit and multiple parallel DG units<strong>.</strong>