scholarly journals Analysis of The Failure Protection System 20 KV CBO T75B Substation Malibu Feeder PT PLN (Persero) UP3 Menteng

2021 ◽  
Vol 6 (2) ◽  
pp. 1422
Author(s):  
Doni Abdul Mukti ◽  
Budi Sudiarto

Protection is a safety in the electric power system installed in the electric power distribution system, power transformer, electric power transmission, and electric generator used to secure the power system electricity from electrical disturbances or overloads by separating the disturbed parts of the electric power system from the undisturbed electrical power system so that the undisturbed electrical system can continue to work. The protection system at the T75B substation has a work failure where when there is a short circuit on the consumer side, it causes the PMT (Power Breaker) for the Malibu Feeder at the Kebon Sirih Substation to trip while the CBO (Circuit Breaker Outgoing) cubicle at the T75B substation does not trip. This resulted in an unexpected widespread blackout. To find out the cause of the failure of the protection system, several tests and analyzes were carried out, namely protection design testing, protection relay coordination testing, protection system construction analysis, protection equipment performance testing. It is hoped that the test results can be used as a reference for improvement so that similar failures do not recur.

2016 ◽  
Vol 856 ◽  
pp. 331-336
Author(s):  
Rexhep Shaqiri

This paper contains a strategy to minimize the power losses in the electrical distribution network of Kosovo. In order to develop the strategy, a model was constructed to simulate an electrical distribution network, and different parameters were included that helped in estimation of the technical power losses in the medium voltage (MV) distribution network. The main objective of this paper is to present approach to minimize technical and non-technical losses in power systems. The analysis of the Kosovo electric power system was performed by means of PSS/E 3.3 software. The results indicate options for reduction of the loses by replacement of old type of transformers and preparation of the MV system for upgrade and change the voltage level from 10 kV to 20 kV. As a first step new 110/10kV transformers can be installed, designed to be reconnected in the future to 110/20kV.


2013 ◽  
Vol 791-793 ◽  
pp. 1889-1891
Author(s):  
Yan Li Fan ◽  
Qing En Li

The low-voltage distribution system is the key component of the electrical power system. Some analysis and research of the low-voltage distribution system is carried out in this paper, which provides some scientific basis to design the low-voltage distribution system. Firstly, the summarize of low-voltage distribution system is taken. The influence to productions and livings of low-voltage distribution system is introduced. Secondly, the mode of connection and design philosophy of low-voltage distribution system is studied in detail, especially the high-rise buildings low-voltage distribution system is concluded and summarized.


2019 ◽  
Vol 10 (1) ◽  
pp. 35-41
Author(s):  
Dwi Ajiatmo ◽  
Imam Robandi ◽  
Machrus Ali ◽  
Betta Aidya Suroya

Short circuit is one type of interference that often occurs in electric power systems. The interference if it lasts a long time will affect the quality and continity of electrical power distribution as well as the reliability and safety of the equipment on the system. To minimize the possibility of interference and to minimize the consequences caused by interference, an analysis of disturbances in the electric power system is needed. This study discusses the classification and analysis of disturbances in the electric power system. The type of interference in the electric power system is classified into two, namely symmetry and non-symmetrical interference. Symmetry disturbances are three phase disturbances which are described by the equation of the sequence of the symmetry component system. Sequence equations from the symmetry component system are positive sequence equations, negative sequence equations, and zero sequence equations. Non-symmetrical interference is a disorder that often occurs in electric power systems, namely the interference of one network to the ground, network interference to the network and interference of two networks to the ground. This research is to classify and to analyze the types of disturbances in the Java-Bali electric power system 500 kV 20 buses in the form of a single line diagram, using Power World Simulator and ETAP Software applications. The simulation results are calculated and display the simulation design of the power system with the tools contained in the program.


2022 ◽  
Vol 2022 ◽  
pp. 1-14
Author(s):  
Muhammad Aamir Aman ◽  
Xin Cheng Ren ◽  
Wajahat Ullah Khan Tareen ◽  
Muhammad Abbas Khan ◽  
Muhammad Rizwan Anjum ◽  
...  

Many underdeveloped countries are facing acute shortage of electric power and short term measures are important to consider to address the problems of power outage, power plant failures, and disaster areas. Distributed generation (DG) is a promising approach for such cases as it allows quick on-site installation and generation of electric power. Injection of DG can improve the system voltage profile and also reduce the system's total power losses. However, the placement and sizing of the DG unit is an optimization problem in the radial distribution system. As a test case, this study examines voltage profile improvement and system power losses for an 11 KV residential feeder at the Abdul Rehman Baba grid station in Pakistan, which is modelled using the Electrical Transient Analyzer Program (ETAP). For various scenarios, several tests are conducted to assess the effects of DG on the distribution system. The results show that proper design considerations of size and location of a DG, to be inserted in to the system, lead to significant reduction in power losses and improvement in voltage profile and thus improvement in the overall efficiency of the power system. The projections of this work can be used to optimize the expansion of a power system and tackling different issues related to voltage profile in distribution sector worldwide.


2020 ◽  
Vol 124 (1281) ◽  
pp. 1789-1797
Author(s):  
M. Bekhti ◽  
M. Bensaada ◽  
M. Beldjehem

ABSTRACTOne of the most critical aspects of a small satellite is the electrical power system (EPS) since the electrical power is necessary for the satellite to operate correctly during its predefined lifetime. The electrical power system consists mainly of solar cells, batteries, voltage converters and protection circuits. The electrical power system is responsible of providing stable power to the rest of the satellite subsystems.In satellite electrical power systems, overcurrent protection is now becoming an important function handled by the power distribution module (PDM). This paper proposes a method to evaluate the suggested protection. With the proposed procedure we should be able to verify that every possible failure does not travel through the EPS and cause a fatal degradation of the electrical power system. This will allow a complete evaluation of functionality of the protection hardware.This paper discusses the design and implementation of the power distribution module (PDM) for the coming generation of small satellites for the Algerian Space Agency (ASAL). The design must provide a reliable protection for the subsystems from the overcurrent associated with a device failure.


2019 ◽  
Vol 10 (1) ◽  
pp. 35-41
Author(s):  
Dwi Ajiatmo ◽  
Imam Robandi ◽  
Machrus Ali

Short circuit is one type of interference that often occurs in electric power systems. The interference if it lasts a long time will affect the quality and continity of electrical power distribution as well as the reliability and safety of the equipment on the system. To minimize the possibility of interference and to minimize the consequences caused by interference, an analysis of disturbances in the electric power system is needed. This study discusses the classification and analysis of disturbances in the electric power system. The type of interference in the electric power system is classified into two, namely symmetry and non-symmetrical interference. Symmetry disturbances are three phase disturbances which are described by the equation of the sequence of the symmetry component system. Sequence equations from the symmetry component system are positive sequence equations, negative sequence equations, and zero sequence equations. Non-symmetrical interference is a disorder that often occurs in electric power systems, namely the interference of one network to the ground, network interference to the network and interference of two networks to the ground. This research is to classify and to analyze the types of disturbances in the Java-Bali electric power system 500 kV 20 buses in the form of a single line diagram, using Power World Simulator and ETAP Software applications. The simulation results are calculated and display the simulation design of the power system with the tools contained in the program.


2017 ◽  
Vol 16 (2) ◽  
pp. 37
Author(s):  
I Dewa Gde Agung Budhi Udiana ◽  
I G Dyana Arjana ◽  
Tjok Gede Indra Partha

Short circuit causing over current problem and can might causing interference of the equipment performance such as distribution transformers also causing widespread disruption occurred. In resolving such interference is required as protection system on the distribution system. Seeing all above is needed coordination between the supporting component of the protection system which is consisted of Over Current Relay (OCR) and Ground Fault Relay (GFR). The research was conducted at PT. PLN (Persero) South Bali Area Network, INDONESIA on recloser in the feeder line of Penebel. OCR setting between the Relay feeder of Penebel, Recloser Celagi, Recloser Bakisan, and Recloser Benana still less selective, with time value coordination between average security was still less than 0,2 second. Then OCR setting and GFR relay feeder of Penebel, Recloser Celagi, Recloser Bakisan, and Recloser Benana was recommended for re-setting in order to minimize disruption and electric power distribution system to be reliable.


Author(s):  
Yuttana Kongjeen ◽  
Krischonme Bhumkittipich

This paper proposes the impact of plug-in electric vehicles integrated into power distribution system based on voltage dependent control. The plug-in electric vehicles was modeled as the static load model in power distribution systems under balanced load condition. The power flow analysis is determined by using the basic parameters of the electrical network. The main point of this study are compare with voltage magnitude profiles, load voltage deviation, and total power losses of the electrical power system. There are investigating the affected from constant power load, constant current load, constant impedance load and plug-in electric vehicles load, respectively. The IEEE 33 bus test system is used to test the proposed method by assigning each load type to a balanced load in steady state and applied the solving methodology based on the bus injection to branch injection matric, branch current to bus voltage matrix, and current injection matrix to solve the power flow problem. The simulation results showed that the plug-in electric vehicles load had the lowest impact compared to other loads. The lowest plug-in values for the electric vehicle loads were 0.062, 119.67 kW and 79.31 kVar for the load voltage deviation, total active power loss and total reactive power loss, respectively. Therefore, this study can be verified that the plug-in electric vehicles load were affected to the lowest of the electrical power system in condition to same sizing and position. So that, in condition to the plug-in electric vehicles load added into the electrical power system with the conventional load type or complex load type could be considered that the affected from the plug-in electric vehicles load in next study.


2020 ◽  
Vol 7 (3) ◽  
pp. 51-57
Author(s):  
Hafid Abibie ◽  
Sulistyowati

The substation is one of the components in the electric power distribution system which plays a very important role because it is the connection between electricity services to customers. In the electric power distribution system, there are disturbances that often occur, one of which is a short circuit. For that, the way to overcome this is using the Distance Relay protection system, OCR / GFR and DEF. The purpose of writing this research is to determine the value of setting relay distance, setting Over Current Rele and Directional Earth Fault relay in order to secure the 70 kV transmission network connected to GI Banaran, which is then simulated using DigSILENT 15.1 software on the Pare line by calculating symmetrical and asymmetrical disturbances. including 3-phase disturbance on February 1, 2018. The simulation results show that the 3-phase disturbance occurs at Zone 1 relay distance of the Banaran Bay Pare substation with a trip time of 0.02 seconds with a fault impedance of 0.083 ohms below the relay impedance value of 0.887 ohms. The coordination between the distance relay on the side of the Banaran Bay Pare substation has worked well because there is no error reading the relay when it will cut off the disturbance.