Comparison Study of Buck Converter with Digital Peak Voltage and Digital Peak Current Control

Author(s):  
Guohua Zhou ◽  
Jianping Xu ◽  
Mingzhi He ◽  
Ni Chen
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Weiming Li ◽  
Jingru Li ◽  
Liang Wei ◽  
Jianjie Wang ◽  
Li Peng ◽  
...  

AbstractDefibrillation is accomplished by the passage of sufficient current through the heart to terminate ventricular fibrillation (VF). Although current-based defibrillation has been shown to be superior to energy-based defibrillation with monophasic waveforms, defibrillators with biphasic waveforms still use energy as a therapeutic dosage. In the present study, we propose a novel framework of current-based, biphasic defibrillation grounded in transthoracic impedance (TTI) measurements: adjusting the charging voltage to deliver the desired current based on the energy setting and measured pre-shock TTI; and adjusting the pulse duration to deliver the desired energy based on the output current and intra-shock TTI. The defibrillation efficacy of current-based defibrillation was compared with that of energy-based defibrillation in a simulated high impedance rabbit model of VF. Cardiac arrest was induced by pacing the right ventricle for 60 s in 24 New Zealand rabbits (10 males). A defibrillatory shock was applied with one of the two defibrillators after 90 s of VF. The defibrillation thresholds (DFTs) at different pathway impedances were determined utilizing a 5-step up-and-down protocol. The procedure was repeated after an interval of 5 min. A total of 30 fibrillation events and defibrillation attempts were investigated for each animal. The pulse duration was significantly shorter, and the waveform tilt was much lower for the current-based defibrillator. Compared with energy-based defibrillation, the energy, peak voltage, and peak current DFT were markedly lower when the pathway impedance was > 120 Ω, but there were no differences in DFT values when the pathway impedance was between 80 and 120 Ω for current-based defibrillation. Additionally, peak voltage and the peak current DFT were significantly lower for current-based defibrillation when the pathway impedance was < 80 Ω. In sum, a framework of adjusting the charging voltage and shock duration to deliver constant energy for low impedance and constant current for high impedance via pre-shock and intra-shock impedance measurements, greatly improved the defibrillation efficacy of high impedance by lowering the energy DFT.


Author(s):  
Deekshitha S. Nayak ◽  
R. Shivarudraswamy

In large and small scale applications, different kinds of variable speed driving systems can be found. For saving the energy consumption of these devices, eco-friendly electronics are used, which lead to the development of the Brushless DC motor (BLDC). Its higher power density, higher efficiency, higher torque at low speed, and low maintenance enhances the use of a BLDC motor. The existing mixer grinder consists of the universal motor, which operates in alternating current supply due to high starting torque characteristics and simple controlling of the speed. The absence of brushes and the reduction of noise in the BLDC extends its life and makes it ideal in a mixer grinder. A solar-powered BLDC motor drive for a mixer grinder is presented in this paper. A DC-DC buck converter is utilized to operate the PV (photovoltaic) array at its maximum power. The proposed hysteresis current control BLDC system has been developed in the MATLAB. The commercially available mixer grinder is presented along with the proposed simulated system for performance comparison. It can be concluded that at the no load condition, the efficiency of the experimental existing mixer grinder is 51.03% and simulated proposed system is 81.25% and at load condition, the efficiency of the experimental mixer grinder is 49.32% and simulated system is 79.85%.


Sign in / Sign up

Export Citation Format

Share Document